Safety requirements 

Before using the multichannel receiver RI-4010M read this user guide 

and follows safety requirements! 

 The multichannel receiver RI-4010M is in continuous mode operating part of the 

security system.  It is supplied with power from AC network.  In order to avoid injuries 
(concerning heat or high voltage impact) or seeking to ensure reliable and long lasting 
operation of the device it is necessary to follow safety requirements. 

The multichannel receiver operates being in horizontal position only. 

Digital  LCD  monitor   of   the   multichannel   receiver   displays   content   of   received 

messages. Light emitting diodes of the receiver mean: 

-

Lighting green – power supplied, the device works from AC network;

-

Lighting red – power supplied, the device works from backup 12 V battery 

Only   trained   staff   being   aware   of   operation   of   used   devices   and   safety 
requirements can perform mounting and maintenance of the receiver. 

 The RI-4010M multichannel receiver is supplied with power from nominal 220 V 

voltage of AC (50

±

1) Hz frequency network and from 12 V backup battery, capacitance 

of which 7Ah. Permissible voltage alteration range is  

±

10

%

. Current from the network 

does not exceed 0, 15 A. The receiver may be plugged in to circuits of AC network 
(sockets). 

Upon operation of safety fuse, the receiver remains to contain inside a lot of parts 

under high voltage. The fuse built in the receiver can not be trusted solely. Additional 
high speed protection must be equipped in phase wire. 

Polarity   of   connective   wires   can   not   be   changed   when   connecting   battery   or 

external 12 V AC source.  Batteries for replacement should be of the same type and in 
compliance with the requirements of the user guide. 

Before unscrewing lids of the receiver unplug it from the AC network. 

The button on the rear board of the receiver can be used to unplug it from the AC 

network by unplugging AC cable from the connector. The devices of unplugging should 
be easily accessible. 

THE MULTICHANNEL RECEIVER RI-4010M MUST BE GROUNDED! 
Lighting suppressors should be equipped to the antenna connectors of the 
modules!

TRIKDIS

Draugystės g. 17, LT-51229   Kaunas, Lietuva, tel. 8-37-408040, faks. 8-37-760554

el. paštas: 

[email protected]

 , 

www.trikdis.lt

 

2

Содержание RI-4010M

Страница 1: ...JOINT STOCK COMPANY MULTICHANNEL RECEIVER RI 4010M version RM1 60619 User guide...

Страница 2: ...age of AC 50 1 Hz frequency network and from 12 V backup battery capacitance of which 7Ah Permissible voltage alteration range is 10 Current from the network does not exceed 0 15 A The receiver may be...

Страница 3: ...ng of the multichannel receiver and preparation to work 10 Setting of exploitation parameters 10 Work with the multichannel receiver without PC 12 Work with the multichannel receiver by using software...

Страница 4: ...ion control and indication bodies connectors and reception modules which ensure signal reception via various communication channels Seven reception modules are available to be built in the platform of...

Страница 5: ...of the receiver about 1000 latest messages and will be transmitted as soon as the devices will be connected and activated The multichannel receiver operates autonomously displays received messages tog...

Страница 6: ...abellin g Parameter Meaning GSM reception module RG1 for data transmission via GSM voice channel 40 4F Radio engineering parameters in compliance with standard requirements GSM reception module RG2 fo...

Страница 7: ...requirements EN 300 113 Sensitivity not worse than 0 3 V Input resistance 50 Received encoded messages RAS 2M LARS LARS1 Configurated information filters according to Time Object number Communication...

Страница 8: ...intains indicated parameters at the air temperature from 10 C to 55 C and relative humidity up to 90 near 20 C 10 Overall dimensions of the receiver do not exceed 450x95x400 mm 11 Mass without set in...

Страница 9: ...annel receiver Operation mode of the receiver is set with the help of control buttons to the left to the right V Down Up exit without changing anything confirm changes and exit Layout of external conn...

Страница 10: ...d Some of the exploitation parameters of the receiver may be changed using programing device SPROG 1 and the program Hyper Terminal Connect AC network to the multichannel receiver via special cable an...

Страница 11: ...ion module s parameters 2 Receiver 01 Device number setting 3 Line reception channel number setting 4 RS 232C Speed setting of the speed of serial port Parameters labelled has separate setting windows...

Страница 12: ...In order to confirm the option press Note TIME SET will be displayed and the receiver will return to Menu Window Back to normal indication mode press In the same way date of the receiver is set althou...

Страница 13: ...the program Detailed process concerning work with the program is described in user manual of the program A Annex OUTPUT TO THE CENTRALIZED MONITORING PROGRAM SURGARD MRL2 DG Heartbeats 1 2 3 4 5 6 7 8...

Страница 14: ...s 15 16 XX SIA event code 17 20 CCCC Zone number SURGARD MRL2 DG Ademco Express 4 2 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 1 r r l s s s s a a a a a a s s s s C C Title Explanation 1 Proto...

Страница 15: ...er supply connector Contact Description 1 Negative terminal 0 V 2 Positive terminal 12 V 3 Free 4 Grounding terminal TRIKDIS Draugyst s g 17 LT 51229 Kaunas Lietuva tel 8 37 408040 faks 8 37 760554 el...

Страница 16: ...TRIKDIS Draugyst s g 17 LT 51229 Kaunas Lietuva tel 8 37 408040 faks 8 37 760554 el pa tas info trikdis lt www trikdis lt 16...

Страница 17: ...EGISTERED B0 Modem has registered in GSM network GSM UNREGISTERED B1 Modem failed to register in GSM network GPRS CONNECTED B2 GPRS server connected RG3 only GPRS DISCONNECTED B3 GPRS server disconnec...

Страница 18: ...TRIKDIS Draugyst s g 17 LT 51229 Kaunas Lietuva tel 8 37 408040 faks 8 37 760554 el pa tas info trikdis lt www trikdis lt 18...

Страница 19: ...TRIKDIS Draugyst s g 17 LT 51229 Kaunas Lietuva tel 8 37 408040 faks 8 37 760554 el pa tas info trikdis lt www trikdis lt 19...

Отзывы: