www.trikdis.com
5
September 2021
FLEXi SP3 user manual
4.2
Alarm system operation modes
Mode
Description
OFF (DISARM)
In this mode, only some of the zones are protected. The alarm will only react to events in zones
set to
Fire
,
24 hour
,
Silent 24h.
ARM
In this mode, all zones are protected. The alarm will react to all possible events.
STAY
In this mode, a part of the zones is protected, but movement is allowed in zones set to
Interior
STAY
and
Instant STAY
. If the alarm system is operating in this mode and a
Delay
zone is
violated, the alarm will activate only after the entry time has elapsed.
SLEEP
In this mode, a part of the zones is protected, but movement is allowed in zones set to
Interior
STAY
and
Instant STAY
. If the alarm system is operating in this mode and a
Delay
zone is
violated, the alarm will activate immediately.
4.3
Control of the alarm system
The alarm system can be controlled using the following devices:
Trikdis
keypads FLEXi SK232LED W, SK232LCD;
Paradox
keypads K32+, K32LED, K32LCD, K636, K10LED V/H, K35, TM50, TM70;
Crow
keypads CR-16, CR-LCD;
iButton
keys;
RFID
cards;
Electric switch, by changing the state of the zone selected by the keyswitch;
Telephone (by phone call or by sending an SMS message with specific contents);
Protegus
app;
Remote command from monitoring station.
4.4
Control access
Control codes are used to give different users different access levels for controlling the alarm system. The user control codes
are four digits long. When choosing and entering control codes, only numbers from 0 to 9 are used, other symbols are not
available.
Types of alarm system control codes:
Administrator code – a six-digit combination (default code - 123456). There is only one administrator code. It cannot be
deleted, but it can be changed. The Administrator code allows to add or delete other users’ control codes. The
Administrator code cannot arm/disarm the alarm system;
User code – a four-digit combination for arming/disarming the alarm system and for temporarily bypassing security
zones. It is recommended to assign every user a personal alarm control code. The memory of the
FLEXi SP3
module can
store up to 40 user codes;
SMS password – six-digit combination for controlling the alarm system via SMS messages (default code - 123456).
4.5
Security functions
Name
Description
Bypass
Temporarily (for one arming of the alarm system) bypasses a security zone when changing the alarm
status. The function is used when the alarm needs to be armed, but a zone is malfunctioning and the
fault cannot be easily repaired.
Bell Squawk
The module can use a short siren signal to warn about the arming and disarming of the premise alarm
system.
Chime
When the alarm system is disarmed, the module can warn that a zone is being violated by turning on
the keypad buzzer and/or a specially programmed PGM output.