FLEXi SP3 user manual

 

Button 

Description 

1, 2 ...9, 0 

Buttons for entering numbers.  

Button for exiting modes and clearing values.  

OK 

Button for confirming the specified choice.  

ARM 

Button for turning on full security mode 

ARM

.  

SLEEP 

Button for turning on 

SLEEP

 mode.  

STAY 

Button for turning on 

STAY

 mode.  

OFF 

Button for turning on 

OFF

 (DISARM) mode.  

 

Note: 

1.

 

To turn off programming mode or delete an incorrectly entered value, press the 

[C]

 button.  

2.

 

If at least one zone is violated, it will not be possible to arm the alarm system (if the 

FORCE

 property 

is not assigned to the violated zones). 

 

5.2

 

Quick arming/disarming of the alarm system  

Arming/disarming the alarm system using a code when the security system has 

STAY

 zones.  

Security modes 

ARM

STAY 

and 

SLEEP

 are switched to 

OFF

/

DISARM

, and 

OFF

/

DISARM

 is switched to 

ARM

 or 

STAY

 mode.  

Changing the security mode:  

1.

 

Enter 

[User code]

.  

a.

 

If the security system has only one section, then skip step 2. If the system has several partitions, the numbers of the 

partitions will appear on the keypad screen, the modes of which the user can change.  

2.

 

Press the numbers of the chosen partitions.  

3.

 

Disarming. Partitions that were in 

ARM

STAY 

and 

SLEEP

 modes will switch to 

OFF

/

DISARM 

mode.  

a.

 

When the security system is disarmed, the following text will appear on the keypad display: 

Disarmed: Area

.  

b.

 

If the 

Bell Squawk

 function is enabled, the siren will activate twice for short periods of time as the alarm switches 

off.  

4.

 

Arming. 

Exit delay 

time will be counted down for partitions that were in 

OFF

/

DISARM

 mode. If a 

Delay

 zone is violated 

during the countdown, 

ARM 

mode will switch on, and if a 

Delay

 zone is not violated, 

STAY

 mode will switch on.  

a.

 

The corresponding text will appear on the keyboard screen: 

Armed: Area

 or 

Stay: Area

.  

b.

 

If the 

Bell Squawk

 function is enabled, the siren will activate once for a short period of time as the alarm switches 

on.  

5.3

 

Arming the alarm in ARM mode  

To turn on

 ARM 

security mode for an security system that is divided into multiple partitions:  

1.

 

Press the keypad button 

[ARM]

.  

2.

 

Enter the 

[User code]

 using the keypad.  

3.

 

Press the buttons with the numbers of the partitions you want to control.  

4.

 

Confirm your selection by pressing the 

[OK]

 button.  

5.

 

Before the 

Exit Delay

 time runs out, leave the premises and close the door.  

a.

 

During the 

Exit  Delay

 time  countdown, the exit time will  be displayed  on the keypad screen. When the security 

system is armed, the following text appears on the keypad display: 

Armed: Area

.  

b.

 

If the 

Bell Squawk

 function is enabled, the siren will activate once for a short period of time as the alarm switches 

on.  

5.4

 

Arming the alarm in STAY mode  

To turn on

 STAY 

security mode for an alarm system that is divided into multiple partitions:  

1.

 

Press the keypad button 

[STAY]

.  

Содержание FLEXi SP3

Страница 1: ...www trikdis com UAB Trikdis Draugystes g 17 LT 51229 Kaunas Lithuania 370 37 408 040 info trikdis lt Security control panel FLEXi SP3 User manual FLEXi SK232LCD keypad September 2021...

Страница 2: ...demarks and patents Other trade names used in this document may be trademarks or registered trademarks belonging to their respective manufacturers or retailers Manufacturer UAB Trikdis Draugystes g 17...

Страница 3: ...MING THE ALARM OFF MODE 8 5 6 1 Switching off the alarm after it has been activated 8 5 7 TEMPORARY ZONE BYPASS BYPASS FUNCTION 9 5 8 VIEWING AND CLEARING ALARM ACTIVATION MEMORY 9 5 9 RESETTING FIRE...

Страница 4: ...ative humidity 80 at 20 C no condensation Main power supply 230 V 50 Hz single phase AC power network through a step down power transformer Power consumption no higher than 40 W Backup power supply 12...

Страница 5: ...l access Control codes are used to give different users different access levels for controlling the alarm system The user control codes are four digits long When choosing and entering control codes on...

Страница 6: ...for each of them individually If the temperature changes beyond the set interval an event message will be formed and sent to users Remote control of devices Additional electronic devices can be connec...

Страница 7: ...following text will appear on the keypad display Disarmed Area b If the Bell Squawk function is enabled the siren will activate twice for short periods of time as the alarm switches off 4 Arming Exit...

Страница 8: ...mode the countdown of the Entry Delay time will begin if anyone enters the premises You must disarm the alarm before the time runs out To switch off protection mode switch on OFF DISARM mode 1 Press...

Страница 9: ...riggering of fire smoke sensors to reset the sensors you must 1 Press and hold the keypad button for 3 seconds a The PGM output that the fire sensors are connected to and that is set to operate in Fir...

Страница 10: ...ter a free two digit user serial number 4 Enter a 4 digit User code 5 Repeatedly enter the 4 digit User code 6 Enter the partitions that the user will be able to control 7 Confirm your selection by pr...

Страница 11: ...button MENU 2 Press the 4 button on the keypad 3 Press the 2 button on the keypad Use the buttons to set the desired volume 4 Confirm your selection by pressing the OK button 5 Press the C button to e...

Страница 12: ...TAY will switch on Existing keys can be deleted and new keys added to an installed and functioning alarm system by using the configuration software TrikdisConfig or a contact key reader Linking keys u...

Страница 13: ...selected alarm system partition E g disarm partition 2 22 3 output no state no Control selected output OUT Controls a specified output OUT State 0 output turned off 1 output turned on 2 turned off fo...

Страница 14: ...Stay mode x is the partition number 1 8 E g STAY 123456 SYS 1 SLEEP SYS x Arm partition x in Sleep mode x is the partition number 1 8 E g SLEEP 123456 SYS 1 FRS Resets the fire sensor s output if the...

Страница 15: ...a safe location Access codes Your Administrator code is ______________________________ Other access codes No Code Control key No No Code Control key No 01A 21 02A 22 03A 23 04A 24 05A 25 06A 26 07A 2...

Страница 16: ...LEXi SP3 user manual Zone Protected space Zone type 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 Temperature sensors Sensor Serial number Controlled space Max temperature Min t...

Страница 17: ...___________________ Time intervals Time for entering _________________________ sec Time for exiting _________________________ sec Siren operation time _________________________ sec Additional informat...

Отзывы: