www.trikdis.com
UAB Trikdis Draugystes g. 17, LT-51229 Kaunas, Lithuania +370 37 408 040
[email protected]
Security control panel
FLEXi SP3
User manual (FLEXi SK232LCD keypad)
September 2021
Страница 1: ...www trikdis com UAB Trikdis Draugystes g 17 LT 51229 Kaunas Lithuania 370 37 408 040 info trikdis lt Security control panel FLEXi SP3 User manual FLEXi SK232LCD keypad September 2021...
Страница 2: ...demarks and patents Other trade names used in this document may be trademarks or registered trademarks belonging to their respective manufacturers or retailers Manufacturer UAB Trikdis Draugystes g 17...
Страница 3: ...MING THE ALARM OFF MODE 8 5 6 1 Switching off the alarm after it has been activated 8 5 7 TEMPORARY ZONE BYPASS BYPASS FUNCTION 9 5 8 VIEWING AND CLEARING ALARM ACTIVATION MEMORY 9 5 9 RESETTING FIRE...
Страница 4: ...ative humidity 80 at 20 C no condensation Main power supply 230 V 50 Hz single phase AC power network through a step down power transformer Power consumption no higher than 40 W Backup power supply 12...
Страница 5: ...l access Control codes are used to give different users different access levels for controlling the alarm system The user control codes are four digits long When choosing and entering control codes on...
Страница 6: ...for each of them individually If the temperature changes beyond the set interval an event message will be formed and sent to users Remote control of devices Additional electronic devices can be connec...
Страница 7: ...following text will appear on the keypad display Disarmed Area b If the Bell Squawk function is enabled the siren will activate twice for short periods of time as the alarm switches off 4 Arming Exit...
Страница 8: ...mode the countdown of the Entry Delay time will begin if anyone enters the premises You must disarm the alarm before the time runs out To switch off protection mode switch on OFF DISARM mode 1 Press...
Страница 9: ...riggering of fire smoke sensors to reset the sensors you must 1 Press and hold the keypad button for 3 seconds a The PGM output that the fire sensors are connected to and that is set to operate in Fir...
Страница 10: ...ter a free two digit user serial number 4 Enter a 4 digit User code 5 Repeatedly enter the 4 digit User code 6 Enter the partitions that the user will be able to control 7 Confirm your selection by pr...
Страница 11: ...button MENU 2 Press the 4 button on the keypad 3 Press the 2 button on the keypad Use the buttons to set the desired volume 4 Confirm your selection by pressing the OK button 5 Press the C button to e...
Страница 12: ...TAY will switch on Existing keys can be deleted and new keys added to an installed and functioning alarm system by using the configuration software TrikdisConfig or a contact key reader Linking keys u...
Страница 13: ...selected alarm system partition E g disarm partition 2 22 3 output no state no Control selected output OUT Controls a specified output OUT State 0 output turned off 1 output turned on 2 turned off fo...
Страница 14: ...Stay mode x is the partition number 1 8 E g STAY 123456 SYS 1 SLEEP SYS x Arm partition x in Sleep mode x is the partition number 1 8 E g SLEEP 123456 SYS 1 FRS Resets the fire sensor s output if the...
Страница 15: ...a safe location Access codes Your Administrator code is ______________________________ Other access codes No Code Control key No No Code Control key No 01A 21 02A 22 03A 23 04A 24 05A 25 06A 26 07A 2...
Страница 16: ...LEXi SP3 user manual Zone Protected space Zone type 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 Temperature sensors Sensor Serial number Controlled space Max temperature Min t...
Страница 17: ...___________________ Time intervals Time for entering _________________________ sec Time for exiting _________________________ sec Siren operation time _________________________ sec Additional informat...