FLEXi SP3 user manual
3.
Press the
[6]
button.
4.
Press the
[1]
key to select the
Dark
keypad screen background, or press the
[2]
key to select the
Light
keypad screen
background.
5.
Confirm your selection by pressing the
[OK]
button.
6.
Press the
[C]
button to exit the
MENU
mode.
5.16
Setting the temperature
The SK232LCD keypad has a temperature sensor. The temperature sensor must be calibrated to show the correct room
temperature. Calibration is carried out by entering the current room temperature on the keypad (this is done only once):
1.
Press the
[MENU]
button.
2.
Press the
[4]
button.
3.
Press the
[7]
button.
4.
Enter the current room temperature.
5.
Confirm your selection by pressing the
[OK]
button.
6.
Press the
[C]
button to exit the
MENU
mode.
After a few seconds, the room temperature will be displayed on the keypad.
6
Control using iButton keys
Note:
If at least one zone is violated, it will not be possible to arm the security system.
A CZ-Dallas reader must be connected to the control panel. iButton keys can be used to set the alarm system security modes
ARM
/
STAY
/
OFF
. Security mode
SLEEP
is unavailable.
Place the iButton key against the key reader. The mode of the alarm system will change to the opposite mode. If the system
was armed, it will disarm. If the system was disarmed, it will arm and the countdown of
Exit Delay
time will start. If the zone
set to
Delay
is not violated during the time for exiting and there are zones set to
Interior STAY
and
Instant STAY
, the security
mode
STAY
will switch on.
Existing keys can be deleted and new keys added to an installed and functioning alarm system by using the configuration
software
TrikdisConfig
or a contact key reader
.
Linking keys using the
CZ-Dallas
reader.
1.
If the
Tag code
list is empty, place the contact key against the “eye” of the reader and hold for 3 seconds. The key will
be linked, added to the first line of the list and become the
Master key
.
2.
To turn on contact key linking mode, hold the
Master key
against the “eye” of the key reader for at least 10 seconds.
3.
To link user keys, hold them against the “eye” of the key reader one by one.
4.
When you are finished linking the user electronic (
iButton
) keys, hold the
Master key
against the key reader again to
disable linking mode.
5.
To delete all keys (including the master key), hold the
Master key
against the reader for at least 20 seconds.
7
Control using RFID cards (tags)
Note:
If at least one zone is violated, it will not be possible to arm the alarm system.
A Wiegand (26/34) RFID reader with keypad must be connected to the control panel. RFID cards can be used to set the alarm
system security modes
ARM
/
STAY
/
OFF
.
RFID tags (cards) can be added by entering their ID numbers in the
TrikdisConfig
software field
Tag code
.
Hold the RFID card against the Wiegand reader or enter the [
User code
] on the Wiegand reader keypad and press [
#
]. The
mode of the alarm system will change to the opposite mode. If the system was armed, it will disarm. If the system was disarmed,
it will arm and the countdown of
Exit Delay
time will start. If the zone set to
Delay
is not violated during the time for exiting
and there are zones set to
Interior STAY
and
Instant STAY
, the security mode
STAY
will switch on.