FLEXi SP3 user manual

 

3.

 

Press the 

[6]

 button.  

4.

 

Press the 

[1]

 key to select the 

Dark

 keypad screen background, or press the 

[2]

 key to select the 

Light

 keypad screen 

background.  

5.

 

Confirm your selection by pressing the 

[OK]

 button.  

6.

 

Press the 

[C]

 button to exit the 

MENU

 mode.  

5.16

 

Setting the temperature  

The  SK232LCD  keypad  has  a  temperature  sensor.  The  temperature  sensor  must  be  calibrated  to  show  the  correct  room 

temperature. Calibration is carried out by entering the current room temperature on the keypad (this is done only once):  

1.

 

Press the 

[MENU]

 button.  

2.

 

Press the 

[4]

 button.  

3.

 

Press the 

[7]

 button.  

4.

 

Enter the current room temperature.  

5.

 

Confirm your selection by pressing the 

[OK]

 button.  

6.

 

Press the 

[C]

 button to exit the 

MENU

 mode.  

After a few seconds, the room temperature will be displayed on the keypad.  

6

 

Control using iButton keys  

Note: 

If at least one zone is violated, it will not be possible to arm the security system. 

 

A CZ-Dallas reader must be connected to the control panel. iButton keys can be used to set the alarm system security modes 

ARM

 / 

STAY

 / 

OFF

. Security mode 

SLEEP

 is unavailable.  

Place the iButton key against the key reader. The mode of the alarm system will change to the opposite mode. If the system 

was armed, it will disarm. If the system was disarmed, it will arm and the countdown of 

Exit Delay

 time will start. If the zone 

set to 

Delay

 is not violated during the time for exiting and there are zones set to 

Interior STAY

 and 

Instant STAY

, the security 

mode 

STAY 

will switch on.  

Existing keys can be deleted and new keys added to an  installed  and  functioning alarm system by using the configuration 
software 

TrikdisConfig

 or a contact key reader

.

  

Linking keys using the 

CZ-Dallas 

reader.  

1.

 

If the 

Tag code

 list is empty, place the contact key against the “eye” of the reader and hold for 3 seconds. The key will 

be linked, added to the first line of the list and become the 

Master key

2.

 

To turn on contact key linking mode, hold the 

Master key

 against the “eye” of the key reader for at least 10 seconds.  

3.

 

To link user keys, hold them against the “eye” of the key reader one by one.  

4.

 

When you are finished linking the user electronic (

iButton

) keys, hold the 

Master key 

against the key reader again to 

disable linking mode.  

5.

 

To delete all keys (including the master key), hold the 

Master key 

against the reader for at least 20 seconds.  

7

 

Control using RFID cards (tags)  

Note: 

If at least one zone is violated, it will not be possible to arm the alarm system. 

 

A Wiegand (26/34) RFID reader with keypad must be connected to the control panel. RFID cards can be used to set the alarm 
system security modes 

ARM

 / 

STAY

 / 

OFF

.  

RFID tags (cards) can be added by entering their ID numbers in the 

TrikdisConfig

 software field 

Tag code

.  

Hold the RFID card against the Wiegand reader or enter the [

User code

] on the Wiegand reader keypad and press [

#

]. The 

mode of the alarm system will change to the opposite mode. If the system was armed, it will disarm. If the system was disarmed, 
it will arm and the countdown of 

Exit Delay

 time will start. If the zone set to 

Delay

 is not violated during the time for exiting 

and there are zones set to 

Interior STAY

 and 

Instant STAY

, the security mode 

STAY 

will switch on.  

Содержание FLEXi SP3

Страница 1: ...www trikdis com UAB Trikdis Draugystes g 17 LT 51229 Kaunas Lithuania 370 37 408 040 info trikdis lt Security control panel FLEXi SP3 User manual FLEXi SK232LCD keypad September 2021...

Страница 2: ...demarks and patents Other trade names used in this document may be trademarks or registered trademarks belonging to their respective manufacturers or retailers Manufacturer UAB Trikdis Draugystes g 17...

Страница 3: ...MING THE ALARM OFF MODE 8 5 6 1 Switching off the alarm after it has been activated 8 5 7 TEMPORARY ZONE BYPASS BYPASS FUNCTION 9 5 8 VIEWING AND CLEARING ALARM ACTIVATION MEMORY 9 5 9 RESETTING FIRE...

Страница 4: ...ative humidity 80 at 20 C no condensation Main power supply 230 V 50 Hz single phase AC power network through a step down power transformer Power consumption no higher than 40 W Backup power supply 12...

Страница 5: ...l access Control codes are used to give different users different access levels for controlling the alarm system The user control codes are four digits long When choosing and entering control codes on...

Страница 6: ...for each of them individually If the temperature changes beyond the set interval an event message will be formed and sent to users Remote control of devices Additional electronic devices can be connec...

Страница 7: ...following text will appear on the keypad display Disarmed Area b If the Bell Squawk function is enabled the siren will activate twice for short periods of time as the alarm switches off 4 Arming Exit...

Страница 8: ...mode the countdown of the Entry Delay time will begin if anyone enters the premises You must disarm the alarm before the time runs out To switch off protection mode switch on OFF DISARM mode 1 Press...

Страница 9: ...riggering of fire smoke sensors to reset the sensors you must 1 Press and hold the keypad button for 3 seconds a The PGM output that the fire sensors are connected to and that is set to operate in Fir...

Страница 10: ...ter a free two digit user serial number 4 Enter a 4 digit User code 5 Repeatedly enter the 4 digit User code 6 Enter the partitions that the user will be able to control 7 Confirm your selection by pr...

Страница 11: ...button MENU 2 Press the 4 button on the keypad 3 Press the 2 button on the keypad Use the buttons to set the desired volume 4 Confirm your selection by pressing the OK button 5 Press the C button to e...

Страница 12: ...TAY will switch on Existing keys can be deleted and new keys added to an installed and functioning alarm system by using the configuration software TrikdisConfig or a contact key reader Linking keys u...

Страница 13: ...selected alarm system partition E g disarm partition 2 22 3 output no state no Control selected output OUT Controls a specified output OUT State 0 output turned off 1 output turned on 2 turned off fo...

Страница 14: ...Stay mode x is the partition number 1 8 E g STAY 123456 SYS 1 SLEEP SYS x Arm partition x in Sleep mode x is the partition number 1 8 E g SLEEP 123456 SYS 1 FRS Resets the fire sensor s output if the...

Страница 15: ...a safe location Access codes Your Administrator code is ______________________________ Other access codes No Code Control key No No Code Control key No 01A 21 02A 22 03A 23 04A 24 05A 25 06A 26 07A 2...

Страница 16: ...LEXi SP3 user manual Zone Protected space Zone type 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 Temperature sensors Sensor Serial number Controlled space Max temperature Min t...

Страница 17: ...___________________ Time intervals Time for entering _________________________ sec Time for exiting _________________________ sec Siren operation time _________________________ sec Additional informat...

Отзывы: