Condense Drain Connections
On the back edge of the condensing unit there are 2
screws, when they are removed they provided 2 cleaning
holes to allow the drain sockets to be cleaned.
The condense drainpipe can be fitted to either the left or
right hand side of the boiler.
To fit the drainpipe, remove the screws holding the back
casing in position and remove the back casing. Supplied
with the boiler is a set of plastic fittings, taking the two
straight connectors fit them on to the two drain connections
off the bottom of the condenser unit. Cut 3 pieces of plas-
tic pipe 175mm long, insert one into each of the straight
connectors, fit the tee fitting on to the end of the pipe
nearest to the side the drain will leave the boiler. On the
other pipe fit the elbow and connect the elbow and tee
together using the other piece of pipe. (165mm long)(Fig 4).
Using the remaining piece of pipe, pass it through the
side casing and connect to the tee fitting. From this point
it is the responsibility of the installer to fit the condensate
trap in a visible position and where no damage can be
caused to the appliance or surroundings if the trap was to
overflow. When installing the condensate trap, it is important
that the trap is filled with water, this provides a seal
against flue gas escape. The trap must be located internally
an an accessible position to allow maintenance to be
carried out. The trap should be checked at regular inter-
vals to ensure it is operating satisfactorily and serviced
annually. (Fig 9 and 10).
Plastic must be used for the drain with a minimum
dia of 15 mm, this can be run into a waste pipe or
external gully or soak away. Avoid external runs were
possible to reduce the risk of freezing
IMPORTANT
The drain pipe must be installed to allow the condensate
to drain naturally from the boiler with a min fall of 1:20.
(See Fig. 9)
Fig. 10
Fig. 9
CONDENSATE OUTLET DRAIN TO
WASTE
CONDENSE
DRAIN PIPE
FROM BOILER
(NOT
SUPPLIED)
CONDENSATE
TRAP
(SUPPLIED
WITH BOILER)
22 MM PLASTIC
PIPE FROM
BOILER
BOILER
DRAIN OR
PURPOSE MADE
CONDENSATE
SOAK AWAY
CONDENSATE
TRAP
IMPORTANT
CONDENSATE MUST DRAIN
NATURALLY FROM BOILER.
THE CONDENSATE TRAP MUST
BE SECURED IN POSITION.
IMPORTANT
TRAP MUST BE FILLED WITH
WATER BEFORE INITIAL FIRING
TO FORM A SEAL AND STOP
FLUE GASSES ESCAPING