Boiler Models
Eurostar 50/90
Boiler Size
Btu
90,000
80,000
70,000
60,000
50,000
Input
Btu/h
93,800
83,600
73,300
63,000
52,700
Kw
27.5
24.5
21.5
18.5
15.5
Output (Non condensing)
Btu/h
90,000
80,000
70,000
60,000
50,000
Kw
26.4
23.4
20.5
17.5
14.6
Output (Condensing)
Btu/h
95,200
84,800
74,400
64,000
53,400
Kw
27.9
24.9
21.8
18.75
15.7
Nozzle
deg EH
0.75 x 80
0.65 x 80
0.6 x 80
0.5 x 80
0.45 x 80
Pump Pressure
psi
125
130
125
140
120
C0
2
%
13.0 - 13.5
13.0
12.55 - 13.0
12.5
12.5
Burner
See Burner Details
Weight (empty)
(kg)
140
Water content
(litre)
26
Flow & return connections
22 mm compression
Flue Socket Dia. (C.F.)
(in.)
4
Max. operating pressure
(bar)
3
(psi)
43.5
Test Pressure
(bar)
4.5
(psi) 65.3
Water side resistance
10 diff (mbar)
25.0
20 diff
(mbar)
8.3
Starting Current
(amp)
3.5
Running Current
(amp)
0.77
Control Thermostat
- Adjustable up to 82° C
Limit Thermostat
- Factory set at 110° C (hand reset)
Casing Finish
- Stove enamelled white with coloured facia trim
Thermal Insulation
- Boiler shell insulated with fibre glass
Optional Extras
- Trianco Balanced Flue Kits and Programmer Kit
Electricity Supply
- 230/280V - 50Hz Fused at 5 amp.
6
TECHNICAL SPECIFICATION
Содержание EuroStar Premier 50/90 Condensing
Страница 10: ...FIG 5 WIRING DIAGRAM 7...