INSTALLATION NOTES
REGULATIONS & SAFETY
This boiler must only be installed by a competent person.
The installation must comply with the following regulations
and standards:
The Building Regulations Part L
I.E.E. Wiring Regulations
Local Water Undertaking bylaws.
BS 4814 - Specification for Expansion Vessels for
Sealed Hot Water Heating Systems
BS 6798 - Measurement of Emitted Noise
BS 5449 - Forced Circulation Hot Water Central
Heating Systems
BS 7074 Part 1 - Expansion Vessel Selection,
Code of Practice for Sealed Water Systems
BS 7074 Part 2 - Expansion Vessel Selection,
Code of Practise for Low and Medium
Temperature Hot Water Systems
BS 7593 - Treatment of Water in Domestic Hot
Water Central Heating Systems
BS 7671 - Electrical Wiring Regulations
BS EN 1264 Part 4 - Installation of Floor Heating,
Systems and Components.
The installer should be aware of his/her responsibilities under
the Health and Safety at Work Act and provide, where
necessary, appropriate protection for the person(s) carrying
out the installation. In the interests of safety, a competent
engineer should install the boiler, and all wiring must be
carried out in accordance with current I.E.E. wiring
regulations.
IMPORTANT: This boiler is only to be fitted on fully-
pumped systems.
It is recommended that a scale-inhibitor is added to prolong
the life of the system. Follow manufacturer's instructions for
best practise on installation.
The appliance must not be operated until the system is full of
water and properly vented and pressurised.
Always switch
OFF
the electrical supply before removing the
front door.
Cardboard packaging is recyclable.
IMPORTANT: To avoid danger of suffocation, please
keep all packaging away from children.
13
Manufacturer's Declaration of Conformity
European Directives Covered by this Declaration:
EN 60335-1: 1994 / A16:2001
EN 60335-2-35:1998 / A1:2000
EN 55014-1:2000
EN 55014-2:1997
EN 61000-3-2:2000
EN 61000-3-3:1995
The Basis on Which Conformity is Being Declared
The products identified herein comply with the requirements of the
Low Voltage Directive (73/23/EEC) and the EMC Directive (89/336/EEC).
Samples of the product have been tested by the manufacturer
and a third-party certification body (The British Standards Institute).
The product has been awarded the British Standards Kitemark (KM 59690).