SIMPLE FAULT-FINDING
Should the boiler fail to start for any reason, please make the
following checks before calling a service engineer:
(1) Is the green light illuminated?
No.
Check for a blown fuse or thrown power-breaker.
Yes
(2) Is the 1st red light illuminated?
No
Check to see if all external controls, such as a room
thermostat or programmer, are operational and calling for
heat and proceed to (3).
Yes
If the light is permanently illuminated, switch off all power to
the appliance for at least 30 seconds. This should reset the
boiler and return it to normal operation. If the problem
persists, then a fault has occurred. Please contact a service
engineer for assistance.
If the light is flashing, this indicates that a fault has occurred
with the heating elements. As it contains 2 elements, in this
case the 4kW model will continue to operate safely at a
reduced output. As the 2kW model only incorporates 1
element, the boiler will not operate.
In either case, a fault has occurred. Please contact a service
engineer for assistance.
(3) Is the 2nd red light illuminated?
Yes
This indicates that the system pressure has dropped to
below 1 bar. Check the system pressure and, if necessary,
re-pressurise to above 1 bar.
No
If all system controls (room thermostat/programmer) have
been checked, please contact a service engineer for
assistance.
IMPORTANT NOTE: Electrical safety checks should only
be carried out by a competent person.
Refer to
page 16
for after-sales service information.
A comprehensive fault-finding guide for the service engineer
can be found on
page 17
.
12
TECHNICAL SPECIFICATION
ELECTRICAL INPUT
SUPPLY CURRENT (amp)
RCD RATING (amp)
WEIGHT (kg)
WATER CONTENT (litres)
WIDTH
DEPTH
HEIGHT
MAINS SUPPLY
MAXIMUM OPERATING PRESSURE
TEST PRESSURE
CONTROL THERMOSTAT
- Adjustable between 30°C and 75°C
PRESSURE SWITCH
- Set at 1 bar
SAFETY VALVE
- Set at 3 bar
EXPANSION VESSEL
- 2 litre capacity
PUMP
- Grundfos UP15-14B
LIMIT THERMOSTAT (FACTORY FITTED)
- Set at 100°C (for wet radiator systems)
LIMIT THERMOSTAT (ALTERNATE)
- Set at 60°C (for underfloor heating systems)
PRESSURE GAUGE
- 0 to 4 bar
CASING FINISH
- Stove enamelled white or bronze
THERMAL INSULATION
- Mineral fibre
2kW
8.5A
13A
16
2.0
360
156
580
230V 50Hz
3 bar
43.5 psi
4.5 bar
65 psi
4kW
17.5A
32A
16
2.0
360
156
580
230V 50Hz
3 bar
43.5 psi
4.5 bar
65 psi