50xx Easyform-ed0811
¥
50xx EASYFORM
17
Troubleshooting
7.2. Solution to failures, for the use of the authorised service center
WARNING - This chapter is for the exclusive use of an authorised technician. For maintenance and replacement of compo-
nents always refer to a service center.
Table 7.2 - Solution to failures
Symptom
Components likely to
be involved
Possible cause
Controls to be carried out
The programming panel
cannot be activated /
The programming panel
switches on but the machi-
ne doesn’t start
The control card has failed
Replace the card
No steam from machine
The solenoid valve has failed
Replace the solenoid valve
Fan does not function
Protection tripped
Reset protection
The electromagnetic switch has failed
Replace the electromagnetic switch
Motor burnt out
Replace the motor
Inadequate ventilation
Fan blades has failed
Check and replace
Fan is dirty
Clean fan
Water leakage during
steam operation
Steam trap failed or dirty (Models 5040, 5042)
Replace or clean the steam trap
High water level (Models
5050, 5055, 5052,
5057)
The electic circuit between board and
probes is faulty
Clean the probes
The control board has failed (Models 5050, 5055, 5052, 5057)
Replace the card
The pump works, water
gets into the boiler but
overflows fron the safety
valve exhaust. (Models
5050, 5055, 5052, 5057)
The level control board
does not receive the
signal that the level has
been reached
The electic circuit between board and
probes is faulty
Check connections and wires
The control board has failed
Replace the board
The pump works but water
does not reach the boiler.
After 4 minutes the unit
turns into protection mode
(Models 5050, 5055,
5052, 5057)
There is no water or the
water flow is too low
Problems of the water line (no
service, closed valves, interruptions
or leaks, ...)
Verify that water reaches the unit in proper
quantity.
Filters or connections are dirty
Clean water intake connections and filters as
per instructions in table 6.1
The pump solenoid valve has failed
Replace the solenoid valve
The pump is always on,
the heating elements are
on (Models 5050, 5055,
5052, 5057)
The pump does not re-
ceive the signal to stop
The level control board of the boiler
has failed
Replace the board
The pump does not work
(Models 5050, 5055,
5052, 5057)
The pump does not re-
ceive the signal to start
Electric circuit between control board
and pump is interrrupdes
Check connections and wires
The level control board of the boiler
has failed
Replace the board
The pump has failed
Replace the pump
There is water in the boiler
but heating elements do
not turn on (Models 5050,
5055, 5052, 5057)
The heating elements do
not receive the signal to
heat
Pressure switch or relative circuit have
failed
Check the circuit and/or replace the pressure
switch
Safety thermostat or relative circuit
have failed
Check the circuit and/or replace the safety
thermostat
The level control board of the boiler
has failed
Replace the board
The coil of the contactor has failed
Replace the contactor
The circuit that drives the heating
elements has failed
Check the electric connections of the contactor
coils
No electricity to the heat-
ing elements
The electric circuit that carries
electricity to the heating elements is
interrupted
Check that the fuses are intact
Faulty element
Replace the element
Faulty contactor
Replace the contactor
The sleeve arms do not
move (Models 5042, 5052,
5057)
The solenoid valve has failed
Replace the solenoid valve
Содержание 5040 EASYFORM
Страница 1: ...50xx Easyform ed0811 5040 EASYFORM 5050 EASYFORM AC 7 5kW 5055 EASYFORM AC 15kW Usage and Maintenance ...
Страница 2: ...50xx Easyform ed0811 ...
Страница 4: ...50xx Easyform ed0811 ...
Страница 18: ...50xx Easyform ed0811 50xx EASYFORM 18 ...
Страница 22: ...50xx Easyform ed0811 50xx EASYFORM 22 Diagrams ...
Страница 24: ...50xx Easyform ed0811 50xx EASYFORM 24 Diagrams ...
Страница 26: ...50xx Easyform ed0811 50xx EASYFORM 26 Diagrams ...
Страница 28: ...50xx Easyform ed0811 50xx EASYFORM 28 Diagrams ...