6.2.1. Electrical circuit maintenance
•
Verify that electrical connections are properly tightened and do
not show oxidation;
•
Verify tightening of solenoid valve coils;
•
Verify state of cable and electrical wiring conditions.
6.2.2. Steam circuit maintenance
Model without boiler
• Verify that steam and condensate return connections are
properly tightened and do not leak
•
Verify that steam valve is in good working order and does not
present leakage
Model with boiler
•
Follow instrucions in table 6.1 for the maintenance of the boiler
group
•
Verify that all connections are properly tightened and do not
leak
•
Verify that the steam valve is in good working order and does
not present leakage
6.2.3. Air circuit maintenance (only for models
with sleeves tensioning)
•
Verify that valves and cylinders do not show any loss of air.
6.2.4. Other controls
•
Check that fan blades are free of dirt and lint deposits.