© Copyright 2019 TRENDnet. All Rights Reserved.
TRENDnet User’s Guide
Industrial Managed Switch Series
77
CLI Configuration
Node
Command
Description
enable
show pd-alive
This command displays the
configuration of the PD Alive Check.
configure
pd-alive (disable|enable)
This command disables or enables
the global PD Alive Check for the
Switch.
interface
pd-alive action
(reboot|alarm|all|none)
This command configures the
action when the system detects
that the host cannot respond the
keep-a-live probe packet.
interface
pd-alive interval VALUE
This command configures the
interval to send the keep-a-live
probe packets to check if the host is
still alive for the specific port.
interface
pd-alive ip IP_ADDR
This command configures the Host
IP address which connects to the
specific port.
interface
pd-alive retry-time VALUE
This command configures the retry
times when no response from the
host for the keep-a-live probe
packet for the specific port.
interface
pd-alive power-off-time VALUE
startup-time VALUE
This command configures the
power-off time and startup time.
Web Configuration
Advanced Settings > PoE > PD Alive Check
Parameter
Description
State
Enables/Disables the PD Alive Check.
Port
Selects a port or a range of ports which you want to configure.
State
Enables/Disables the PD Alive Check for the specific port(s).
IP Address
Specifies the Host IP address which connects to the port.
Interval
The interval to send the packet probes to check if the host is
still alive.
Retry Time
The retry times when no response from the host for the keep-
alive probe packet.
Action
The action to the Power Device when the system detects that
the Power Device cannot respond the keep-a-live probe packet.
The options have Reboot / Alarm / All /None.