© Copyright 2019 TRENDnet. All Rights Reserved.
TRENDnet User’s Guide
Industrial Managed Switch Series
71
Word 4 Hi byte = ‘-’
Word 4 Lo byte = ‘1’
Word 5 Hi byte = ‘.’
Word 5 Lo byte = ‘1’
Word 6 Hi byte = ‘.’
Word 6 Lo byte = ‘0’
Word 7 Hi byte = ‘.’
Word 7 Lo byte = ‘S’
Word 8 Hi byte = ‘0’
Word 8 Lo byte = ‘\0’
0x0060
16 words
ASCII
Firmware Release Date=” Mon Sep 30
18:51:45 2013”
0x0070
3 words
HEX
Ethernet MAC Address
Ex: MAC = 00-01-02-03-04-05
Word 0 Hi byte = 0 x 00
Word 0 Lo byte = 0 x 01
Word 1 Hi byte = 0 x 02
Word 1 Lo byte = 0 x 03
Word 2 Hi byte = 0 x 04
Word 2 Lo byte = 0 x 05
0x0080
1 word
HEX
Power 1(PWR) Alarm, DIP switch 1
need ON
0x0000: no alarm
0x0001: input voltage < 44V
0x0002: input voltage > 57V
0x0003: No PWR input
0x0081
1 word
HEX
Power 2(RPS) Alarm, DIP switch 1
need ON
0x0000: no alarm
0x0001: input voltage < 44V
0x0002: input voltage > 57V
0x0003: No RPSinput
0x0090
1 word
HEX
Fault LED Status
0x0000: No
0x0001: Yes
Port Information
0x0100 to
0x0109
1 word
HEX
Port 1 to 10 Link Status
0x0000: Link down
0x0001: 10M-Full-FC_ON (FC: Flow
Control)
0x0002: 10M-Full-FC_OFF
0x0003: 10M-Half-FC_ON
0x0004: 10M-Half-FC_OFF
0x0005: 100M-Full-FC_ON
0x0006: 100M-Full-FC_OFF
0x0007: 100M-Half-FC_ON
0x0008: 100M-Half-FC_OFF
0x0009: 1000M-Full-FC_ON
0x000A: 1000M-Full-FC_OFF
0x000B: 1000M-Half-FC_ON
0x000C: 1000M-Half-FC_OFF
0xFFFF: No port
0x0200 to
0x0213
(port 1)
0x0220 to
0x0233
(port 2)
…
0x0320 to
20 words
ASCII
Port 1 to 10 Description
Port Description = “100TX,RJ45.” Or
“1000TX,SFP.”
Word 0 Hi byte = ‘1’
Word 0 Lo byte = ‘0’
Word 1 Hi byte = ‘0’
Word 1 Lo byte = ‘T’
…