QUANTUM NXT DI HEATER OPERATION / MAINTENANCE MANUAL
PAGE 37
8 TROUBLESHOOTING
Danger!
If the heater is energized while the cabinet door is open, an arc flash hazard may exist.
Only trained personnel should attempt to energize the heater with the cabinet door
open.
Display is Not Illuminated
Cause:
Solution:
EMO button engaged
Twist EMO in direction of arrows (see Section 2.3).
No power at main circuit breaker
Review wiring procedure (see Section 3, Installation).
Control breaker is tripped
Reset breaker
Main breaker is OFF
Main breaker to ON.
Alarm Sounds
Cause:
Solution:
DI supply pressure
Check water supply pressure at source. Verify supply is at least
15 psig.
Liquid level
Check water supply at source.
Check over-pressure relief diaphragm.
Verify flow is on.
Check plumbing for trapped air bubbles, see Section 4.1.e
Leak sensor
Check manifold and heater modules for leak. Visually inspect
leak tray.
Thermocouple damaged
If fault repeats, check thermocouple leads to OTC for continuity.
Check T/C plugs in top heater modules.
Plugged orifice in heater
Check fluid lines in and out of manifold for flow.
Over-temperature alarm
Check if heater element has failed and replace module (see
section 7.1).
If fault reports, check T/C leads to OTC for continuity.
Verify fan operation.
Check for shorted SSRs (shut down per 7.1 before
checking SSRs)
Low/Stop Flow
Check box on configuration page is checked, see section 2.4.f.
Flow switch is set too low see section 2.4.f