LYNX Plus Programming Manual Rev 2.1c
Page
85
Program 05-17-IP : System Timing Parameters – 17
05-17-IP SYS PAR
0 1 0 0 0 0 0 0
IP =
Item Pointer (01-08)
Value for each Item
IP
Value
Default
Item Description
01
0-1
1=
Reserved
02
0-1
1=32K bps
Voice Compression
03
0-1
0=No
Extension Number Announcement for DISA
04
0-8
2=2 seconds
DISA & ECF Access Delay Time - Lunch
05
0-9
0= None
DTMF CLI Leading Digits
06
0-1
0= None
DTMF CLI Trailing Digits
07
0-2
0= No
CID Call Block or Transfer to Voicemail
08
0-3
4= Seconds
Minimum Mailbox Record Time
Description:
01. Reserved
02. Voice Compression
The default setting for the 256Mb VMU can be 32K or 16K bps compression rate. For customers who
want to increase the recording capacity this parameter allows the compression rate to be 16 KBPS. That
will double the available amount of storage time on the VMU while voice quality will be decreased. In the
new version of 1GB VMU2, there is no voice compression, and message is 64K uncompressed.
IP \ Value
0
1
05-17-02
16K bps
32K bps
03. Extension Number Announcement for DISA
The Auto Attendant has two ways of announcement for transferring the call. The stanadard
announcement is “Please hold while I transfer the call.” Optional announcement is “ xxx, Please hold
while I transfer the call”. The xxx is the extension number being transferred to. After the above
announcement, the system will send the Ring-Back tone to external calling party.
IP \ Value
0
1
05-17-03 “ Please hold while I transfer the call” “ xxx, Please hold while I transfer the call”
Содержание Lynx DK6 Series
Страница 1: ...Telephone System Master Programming Manual Rev 2 1c ...
Страница 2: ......
Страница 24: ...Page 24 ...
Страница 34: ...Page34 ...
Страница 40: ...Page40 ...
Страница 44: ...Page44 DK6 Key Telephone Key Layout 18 Button DK7 Key Telephone Key Layout ...