LYNX Plus Programming Manual Rev 2.1c
Page
117
Program 35-tk-IP : Trunk Specifications – 1
35-tk-IP TK SPEC
0 1 0 0 3 0 0 0
tk =Trunk No. (01-12), IP =
Item Pointer (01-08)
Value for each Item
IP
Value
Default
Item Description
01
0-1
0=CO
Trunk Type
02
0-1
1=DTMF
Dialling Signal
03
0-8
0=No
External Call Forward
04
0-8
0=No
DISA
05
0-3
3=Yes
Pick Up
06
0-9
0=No
Loud Bell
07
0-5
4=Private
Inward Line Ringing Type - Day
08
0-5
4=Private
Inward Line Ringing Type - Night
General:
This program permits each trunk line to be assigned to different parameters.
Description:
01. Trunk Type (CO / PABX)
IP
Value Value Description
35-tk-01
0
Trunk line is Central Office line.
35-tk-01
1
Trunk line is installed behind a PABX or Centrex.
When user makes a Redial Call, system will automatically add (if trunk line is installed behind PBX) or
delete (If trunk line is Central Office line) a leading digit (0 or 9 that is assigned at mode 05-03-04 PBX
Outgoing code).
This setting will also force the CLI Delay Ring Time (Mode 05-14-06) for this trunk to 0.
02. Trunk Signal (Pulse / DTMF )
IP
Value Value Description
35-tk-02
0
Trunk dialling signal is Dial Pulse.
35-tk-02
1
Trunk dialling signal is DTMF (Touch-Tone).