background image

 

LYNX Plus Programming Manual Rev 2.1c 

 

 

Page 

137

 

 

 

Program  46-stn-IP : Station Class of Service – 4 

 

46-stn-IP STCOS 
1  1  0  3  0  7  d  0 

stn= Station No. (2-4 digits), IP =

 

Item Pointer (01-08) 

Value for each Item 

 

IP 

Value 

Default 

Item Description 

01 

0-8 

0= None 

Dial [87] Trunk Group 

02 

0-9 

0= 0 

Send Message Wait Signal Level 

03 

0-2 

2= MIC will switch on 
for Intercom calls 

Automatic Answer Capability / Internal CLIP 

04 

0-7 

3= Recall 

DISA/ISDN In dial Recall Capability 

05 

0-9 

0= No Limit 

Maximum Number Of Transfer Times Allowed 

06 

0-7 

7= Yes 

Door Unlock/DND/CFWD Access 

07 

0-9 

0= d 

ACP Door Phone Hunt Grp./Permanent C/FW Grp. 

08 

0-7 

0= Normal 

SLT Ring Cadence Settings 

General: 

 
This program permits each station to be assigned to a different Class of Service. 

 
Description: 

01. Dial [87] Trunk Group  

If this setting is from 1 to 8, after the station dials [87] (or dials [9]), the system will automatically search for 
a free line which is assigned in group 1 to 8 in Program Mode 38. 
If the setting is 0, then no dial 87 group is available to this station. 

 

Related System Programming Mode: 

36, 38, 41-ST-04, 46-ST-01 

02. Message Waiting Level 

The Stations assigned higher levels can leave message for stations with the same or lower levels.  Ten 
levels (0-9) are available (9=highest level, 0=lowest level). Stations which are set to 0 can not send a 
message waiting information but only receive a message waiting from the voice mail unit. 

IP 

Value  Value Description 

46-stn-02 

Can do Message Waiting to Stations that are assigned level 0-9 

46-stn-02 

Can do Message Waiting to Stations that are assigned level 1-8 

46-stn-02 

Can do Message Waiting to Stations that are assigned level 1-n 

46-stn-02 

Only receive Message from Stations whose assigned level is > 2. 

46-stn-02 

Can only receive Messages from Voice Mail. 

 
For Hotel / Lodging applications, it is recommended that you assign a message waiting level so that guest 
telephones cannot leave a message for another station in the system. If you set the guest room to 1 then 
the room phone cannot leave a message for another station and can ONLY get a message waiting 
indication from the console operator or the voice mail system. 
Message levels of the same value above 0 can leave messages for one another. Lower message levels 
cannot leave messages for higher levels.  
Message level 0 allows messages to be left on a station only by the system Voice Mail Card. When 
selected for a station, pressing the MSG key (FN:3) will always call the Voice Mail. 

Содержание Lynx DK6 Series

Страница 1: ...Telephone System Master Programming Manual Rev 2 1c ...

Страница 2: ......

Страница 3: ...roducts for a particular purpose 2009 2011 TransTel Communications Inc This document or any parts thereof are not to be reproduced or transmitted in any form or by any means electronic or mechanical including photocopying recording or information storage and retrieval systems for any purpose whatsoever without the express written permission of TransTel Communications Inc Revision History Date of R...

Страница 4: ...ility of System Applications 17 Varied Extension Alternatives 18 Liquid Crystal Display 19 Mechanical Specifications Key Service Unit 20 Mechanical Specifications Battery Back Up Housing 20 Environmental Specifications 20 Features 21 System Features 21 Station Features 22 Parts Peripherals 23 System Modules 23 Type of Phones 23 Peripheral Devices 23 Optional Interface Cards 23 System Installation ...

Страница 5: ...abling 37 Door Switch Relay Connection 37 Sensor Connection 37 RS232 Port Connection 38 VMU Setup 38 External Music on Hold Source 38 Power On and Operational Test 39 Operational Tests 39 Special Immunity Protection for System and terminals 39 Introduction 41 New Systems 41 Basic Programming Commands 42 Enter Programming 42 Alphanumeric Entry 43 DK6 Key Telephone Key Layout 36 Button 43 DK6 Key Te...

Страница 6: ...ntrex Outgoing Code Refer to Program 35 TK 01 53 05 Toll Access Code 54 06 Station Numbering Plan 54 07 Internal Dial Tone Pattern 54 08 Door Phone Ring Pattern 54 Program 05 04 IP System Timing Parameters 04 55 01 System Baud Rate Setting 55 02 Dial 9 Flag 55 03 Action for Call Duration Limiting 55 04 12 24 Hours Clock 56 05 SLT Hook Flash Answer Delay 56 06 Speed Dialling Distribution 56 07 Sing...

Страница 7: ...onsole Queuing 68 03 Clear Forward Signal Loop Disconnect Detection 68 04 DISA Busy Tone Detection 69 05 Reserved 69 06 ACD 1 Enable Time 69 07 ACD 1 Segment 2 Recall Time 69 08 ACD 1 Release Time 70 Program 05 10 IP System Timing Parameters 10 71 Program 05 11 IP System Timing Parameters 11 73 0 1 DTMF Caller ID Leading Digit 73 02 Number of DISA Passwords 73 03 Select Music on Hold or Ring Back ...

Страница 8: ...ISA Single Digit Dialing Level 83 04 VMU Language Service 84 05 Reserved 84 06 Reserved 84 07 ACP Data Output Format 84 08 Reserved 84 Program 05 17 IP System Timing Parameters 17 85 01 Reserved 85 02 Voice Compression 85 03 Extension Number Announcement for DISA 85 04 DISA ECF Access Delay Time Lunch 86 05 DTMF CLI Leading Digits 86 06 DTMF CLI Trailing Digits 86 07 Call Block or Transfer to Voic...

Страница 9: ...05 24 IP System Timing Parameters 24 94 01 Reserved 94 02 Reserved 94 03 Reserved 94 04 LYNX Monitor System Tracking 94 05 Reserved 94 06 LYNX Monitor Output 94 07 LYNX Monitor DSP trace 95 08 LYNX Monitor VMC Trace 95 Program 06 IP Relay Assignment 96 Program 07 Gp IP Flexible Key Group Assignment 97 Program 09 nnn DP System Speed Dial 100 Program 10 GP IP Intercom Single Digit Assignment 102 Pro...

Страница 10: ...xternal Call Forward ECF 118 04 DISA ECF Direct Inward System Access External Call Forward 118 05 Pick Up 118 06 Loud Bell 119 07 Inward Line Ringing Method Assignment Day 119 08 Inward Line Ringing Method Assignment Night 120 To set a trunk name 120 Program 36 gp tk Trunk Group Assignments 121 Program 37 tk Busy Out Trunks 122 Program 38 gp tk Dial 87 Trunk Group Assignments 123 Program 39 IP Sen...

Страница 11: ...ercom Call Limitation 135 02 ACP Hear BGM at idle state 135 03 Incremental Increase Ringing Volume 135 04 Allow Trunk Access 136 05 Intercom Calls to Different Station Groups 136 06 Receive Break Alarm 136 07 Allow Unrestricted Speed Dial Access 136 08 Record Station s SMDR Data 136 Program 46 stn IP Station Class of Service 4 137 01 Dial 87 Trunk Group 137 02 Message Waiting Level 137 03 Automati...

Страница 12: ... gp IP Station Hunt Group Assignment Night 151 Program 75 Num IP LCR Analysis Table 152 Program 76 Num Tm LCR Routing Table 153 Program 77 Num LCR Modifying Table 154 Program 78 stn IP Station Class of Service 6 155 01 LCR Routing Level 155 02 LCR Direct Access a Trunk 155 03 1A2 Emulation Station Programming 156 04 Call Forward Busy Transfer Group 156 05 External Notification Voicemail 156 06 Cal...

Страница 13: ...g Code 172 Trunk Specifications 172 Speed Dial 173 Auto Redial 173 Intercom Calls 173 Intercom Call Signalling 173 Step Call 173 Dial Tone Pattern 173 Single Digit Intercom 173 Direct Station Select 173 Dial 0 Call Operator 173 Intercom Dialling Restriction 173 Busy During Conversation 174 Hold and Hold Recall 174 Busy Remind Camp On 174 Call Split 174 Transfer 174 Message Waiting Level 174 Overri...

Страница 14: ...ch 177 Voice Mail Integration 177 ACD 1 operation 178 Clear down of unanswered calls 178 Auto Attendant and DISA operation 179 Enabling Auto Attendant DISA Answer of Incoming Calls 179 DISA Answer Delay Time 179 Clear down of unanswered calls 180 Recording the DISA Messages 180 Programming Single Digit DISA 182 Installing ACP s 182 About security 182 ACP Applications 183 How to set up as a door ph...

Страница 15: ...seful to determine the quantity of devices you may connect to your telephone line and still have all of those devices ring when your telephone number is called In most but not all areas the sum of the REN s of all devices connected to one line should not exceed five 5 0 To be certain of the number of devices you may connect to your line as determined by the REN you should contact your local teleph...

Страница 16: ...nstalled and used properly and in strict accordance with the manufacturer s instructions may cause interference to radio and television reception It has been type tested and found to comply with the limits for a Class A computing device in accordance with the specification in Subpart J of Part 15 of FCC Rules which are designed to provide reasonable protection against such interference in a reside...

Страница 17: ...rk effectively Easy Installation Factory Ready All Lynx systems are ready to go right out of the box A well thought out default database is factory installed on each system which meets the needs for most installations This alleviates hours of on site time minimizing installation costs for both dealer and customer Small Compact The Key Service Unit s small size takes little space for installation E...

Страница 18: ...TransTel DK series Keyphone Door Phones and conventional industry standard single line sets Modem Answering Machine Cordless phone etc directly to the KSU This feature provides you with the choice to select different extension equipment to suit individual applications ...

Страница 19: ...lines by name and self prompting displays for feature access Station feature usage is made simple with the help of the LCD display Continuous prompting information is displayed during calls so that users know what to do and when to do it 32 64 character LCD Display shows Time Last number dialled Dialed telephone number The status of operation function Voice Mail Messages Absent messages CO Line Na...

Страница 20: ...r Switch Twisted 1 Pair 2 wires External Sensor Twisted 1 Pair 2 wires Single Line Telephone Twisted 1 Pair 2 wires Mechanical Specifications Key Service Unit CABINET DIMENSIONS 425mm W 85mm D 315mm H 16 7 3 3 12 4 WEIGHT 3 9 Kg Configuration 4 x 8 8 59 lbs Mechanical Specifications Battery Back Up Housing CABINET DIMENSIONS 36 cm W 13 cm D 44 cm H WEIGHT With Batteries 16 lbs Without Batteries 4 ...

Страница 21: ...ackup Memory Flexible Expansion Flexible Ringing Assignment Flexible Key Group Assignment Flexible Number Plan 2 3 or 4 Digit Flexible Time Format 12 24 Hour Forced Account Code Assignment Intercom Intercom Single Digit Assignment Intercom Ring Voice Select Intercom Dialling Restriction Host PABX Access Hot line Line Group Assignment Loud Bell Assignment Multiple Attendant Consoles Multiple Trunk ...

Страница 22: ...LCD Phones Calling Number Display LCD Phones Camp On Chain Dialling Conference Dial By Name LCD Phones Dial Access to Attendant Direct Station Selection DoorPhone Access Do Not Disturb DND Dual Color LED Duration Time Display LCD Phones Executive Override Barge In External Call Forwarding Flash Open Loop Timed Flash Hands free Answer Back Hearing Aid Compatibility Headset Compatibility Hold Exclus...

Страница 23: ...Multifunction Key Telephone with 2 line LCD display speakerphone Handsfree headset jack 36 dual color keys and 7 function keys for feature access DSS CO Lines and speed dial DK6 12 Multifunction Key Telephone with 2 line LCD display speakerphone Handsfree headset jack 12 dual color keys and 7 function keys for feature access DSS CO Lines and speed dial DPU1 Digital Door phone weather resistant ACP...

Страница 24: ...Page 24 ...

Страница 25: ...rvice personnel Main components of the system are NOTE Please follow the directions step by step The Lynx system should be installed in strict accordance with this manual Key Service Unit which includes Power Supply Unit G1K PWU Main Board Unit G1K MBU2 Common Control 4 digital port circuits and 4 SLT ports On board messaging and Auto Attendant Optional Expansion Cards TLU Card 2 CO 4 single line ...

Страница 26: ...URGE PROTECTION A Surge Protector is recommended on the dedicated AC line VENTILATION AND TEMPERATURE Humidity 10 to 95 relative non condensing Temperature 32 to 113 0 to 45 EARTH GROUND A proper ground connection 14 AWG SERVICEABILITY Lighting conditions and working space adequate for future service Equipment Requirements Unpack Check and Verify Equipment Unpack the telephone equipment boxes and ...

Страница 27: ...nd expansion card perform a visual inspection to assure the printed circuit card is installed properly 1 Position the cabinet on a flat surface like a table or countertop Avoid doing this on carpet 2 Remove the 4 screws located at the corners of the cabinet and lift the front cover off 3 Locate the expansion and option cards and unpack them at this time Card Introduction G1K PWU Power Supply Inter...

Страница 28: ... capacitor which provided for Real Time Clock 5 CN2 To G1K TLU CN1 6 CN6 CO 1 CO 3 input from Central Office 7 CN8 External Music 8 CN7 Relay Sensor Ex Page 9 CN10 RS232 connection 10 JP1 Clear Flash Memory Normal Operation 11 LED1 System operation indication when slow flashing is normal 12 CN12 Connections for Digital Ports 11 14 ST1 ST4 and SLT Ports 15 18 ST5 ST8 ...

Страница 29: ... ST10 CN4 Connections for SLT port 21 22 ST11 ST12 G1K NFC 128 CF Card G1K NFC 32kbps G1K NFC 16kbps Total 1 Unit Duration Duration Total 1 Unit Duration Duration Unit Duration mins hours Unit Duration mins hours secs secs 128M For a description of the VMU and Auto Attendant setup and configuration including how to record messages see the section at the end of the Installation Manual ...

Страница 30: ... Power off the system before installing card Install 2 spacers to the MBU by removing screws from the MBU and replacing with spacers Align CN1 of the G1K TLU card with CN2 of the G1K MBU Align the hole on right side of G1K SLU with the standoff ...

Страница 31: ...e you connect and power on the system The input voltage is set according to the Customer s requirement before shipping However it is important to verify that the setting is correct prior to initial system power up Power adapter supply voltage options for the unit 100 VAC 100 to 120 V AC 50 60Hz or 240 VAC 205 to 265 V AC 50 60Hz Mount Power adapter Using screws provided with the system mount the p...

Страница 32: ...ing instructions should also be read and followed 1 Charge the batteries provided with or identified for use with this product only in accordance with the instructions and limitations specified in this manual 2 Observe proper polarity orientation between the batteries and battery charger 3 Do not mix old and new batteries in this product 4 Do not mix batteries of different sizes or from different ...

Страница 33: ...phone DK6 DK7 A cable cover is provided with the KSU Station cables enter from the bottom of the KSU Remove the cover and route the station cable through the hole Terminate the station wires with the connectors that are provided The stations will connect to the KSU as shown on the main panel above on connector locations ST1 ST4 port11 port14 Connect the stations to Inner pair for Port 1 and outer ...

Страница 34: ...Page34 ...

Страница 35: ...main panel above on connector locations ST1 ST4 port11 port14 Connect Tip Ring terminals from KSU G1K MBU to the ACP DPU connector 6 contacts There is no polarity requirement on Tip and Ring Connect Relay for applications such as door open to the ACP DPU connector 6 contacts Connect Sensor for applications such as door open alarm to the ACP DPU connector 6 contacts Mount ACP connector on to ACP DP...

Страница 36: ...ip terminal with GRN terminal screws of the modular jack Ring with RED There is no polarity requirement on Tip and Ring 2 conductor wiring is required for Single Line Telephones CO PABX Connections Make your CO line connection to the telephone company on this connector Pins 3 and 4 of the connector are for the CO line RJ 11C 2 wire modular connector is required 2 conductor wiring is required Music...

Страница 37: ...G1K MBU 2 conductor wiring is required Connect the door switch to pins 1 and 6 of the RJ 11 connector Sensor Connection The Sensor connector on G1K MBU may be used for the External Sensor input The sensor may be configured for normally open or normally closed operation 2 conductor wiring is required Connect the sensor to pins 2 and 5 of the RJ 11 connector Refer to System Programming Mode 39 Senso...

Страница 38: ...es are recorded in G1K NFC Flash Ram and do not require any battery backup to maintain For a description of this procedure see mode 25 in the Programming manual To access the MBU Flash Ram to setup or record messages dial 89 from the Console External Music on Hold Source The Lynx system has an external Music port but relies on using the 2 Minute MOH message recorded on the G1K NFC Flash ram This m...

Страница 39: ...rational Tests Check each telephone and CO line to verify that outgoing lines are connected properly Check that intercom calls can be made from extension to extension WARNING DISCONNECT THE POWER SUPPLY FROM THE AC POWER SOURCE BEFORE WIRING OR CHANGING ANY WIRING Connect the Battery Backup AFTER AC power has been connected to the Power Supply Disconnect Battery Backup BEFORE disconnecting AC powe...

Страница 40: ...Page40 ...

Страница 41: ...o press SAVE key then you will see the LCD display as follow Then enter 2 5 and press SAVE You will be in Program Mode 25 01 The display will show Enter 2 to reset entire data and phone will beep and return to the previous screen You may begin database entry at this point or exit system programming by pressing SPK key or by lifting and replacing the handset A station can access the trunk line and ...

Страница 42: ...ext section in any multiple part form DSS 3 CURSOR LEFT Moves the programming cursor to the left position DSS 4 CURSOR RIGHT Moves the programming cursor to the right position DND CN DON T CARE Enters a Wild Card don t care into Account Codes or Toll control entries LCD will display d lower case letter d to indicate don t care entry HOLD PAUSE Inserts a Pause when programming a Speed Dial Entry or...

Страница 43: ...an entry is made that is not within valid system parameters the system will not accept the entry when SAVE is pressed The Speaker on the programming set will return a busy tone and the LCD Display will place the programming cursor under the invalid entry You may make corrections and press SAVE again If multiple errors are made the system will continue to return you to the illegal entries until the...

Страница 44: ...Page44 DK6 Key Telephone Key Layout 18 Button DK7 Key Telephone Key Layout ...

Страница 45: ...reetings From Console Ext 11 Dial 86 for Extension Voice Mail Ringing Assignments Extension 11 12 13 and 14 will ring on all incoming calls in Day Mode Extension 11 12 13 and 14 will ring on all incoming calls in Night Mode Faxibility setup on Line 3 by default Fax call will ring extension 18 General Setup Digital extensions 11 12 13 and 14 analog extensions 15 and 16 and virtual extensions 41 and...

Страница 46: ... 0 5 To clear all entries press REDIAL 6 Lunch ringing is programmed in Mode 94 Note Faxibility on Line 3 set to ring Extension 18 Program 02 tk IP Night Ringing And Ringing Line Preference Assignment 02 tk IP FLX NIG 11 12 13 14 tk Trunk No 01 12 IP Item Pointer 01 26 Assigned station number General This program assigns each incoming line to ring the programmed stations The ringing methods can be...

Страница 47: ... in Mode 05 03 08 Program 04 gp IP Console Assignment 04 gp IP Console 11 00 00 00 gp Station group 01 08 IP Item Pointer 01 04 Assigned station number 2 to 4 digits General This program permits the selection of the consoles in each station group Consoles are stations that can program System speed dials Record system Voice messages receive hold recalls and ring when callers dial 9 0 for the operat...

Страница 48: ...tically transferred to the Console IP Value 0 1 2 3 4 5 6 7 8 9 Unit 05 01 01 30 60 90 120 150 180 210 240 253 sec Note Infinite It means no Hold Recall 02 Exclusive Hold Recall Time This parameter sets the time duration from the line is put on Exclusive Hold to the held call recalls the station After a pre determined recall time see 05 01 03 Hold Recall Timeout if the called station still does no...

Страница 49: ... an incoming trunk rings periodically the busy station before it answers the call It is used to remind the busy station that another trunk is waiting on the line A muted one second ring will be given to the station through the speaker to indicate the waiting call The ring will be repeated every this busy remind cycle time interval This parameter also sets the timing for the SLT Camp On feature see...

Страница 50: ...ransfer Time This parameter sets the timer between a call is ringing a station set Call Forward No Answer and then be transferred to the station been forwarded IP Value 0 1 2 3 4 5 6 7 8 9 Unit 05 01 08 10 20 30 40 50 60 70 80 90 100 ms ...

Страница 51: ...ial Tone is given a Busy Tone will be heard IP Value 0 1 2 3 4 5 6 7 8 9 Unit 05 02 01 0 2 4 6 8 15 30 60 120 254 Sec 02 SLT Inter Digit Timeout This parameter is for SLT Single Line Telephone If the interval between digits dialled exceeds this assigned timer a Busy Tone will be given IP Value 0 1 2 3 4 5 6 7 8 9 Unit 05 02 02 0 2 4 6 8 15 30 60 120 254 Sec 03 Auto Redial Access Time PSTN Lines Th...

Страница 52: ... 160 240 400 600 800 1000 1200 1400 ms UK Italy Aust 60 80 100 120 140 160 180 200 300 600 ms 06 SLT Hold Signal Time This parameter permits the selection of the Flash time from a single line telephone that the system will recognize as a Hold signal if the time is greater than this hold signal time but less than the SLT release time Program 05 02 04 IP Value 0 1 2 3 4 5 6 7 8 9 Unit 05 02 06 70 80...

Страница 53: ...g to the assigned dial 9 trunk group when automatic dialling features are used i e Speed Dial Save Redial Redial etc IP Value 0 1 05 03 02 Allowed Not Allowed 03 Intercom Call Signalling Method This parameter selects the Intercom calling method The user can still override this selection by dialling 3 after initiating an intercom call Individual stations can be set to automatic microphone switch on...

Страница 54: ... analog phone will receive the 2 Burst tone if call forward or DND has been set for that extension 2 Value 2 and 6 is particularly designed for use when there is an external Voice Mail system connected to the system as some Voice mail units have problems with the broken dial tone 3 Value 6 will also provide what is known as Stutter dial tone to extensions when they are left a message useful where ...

Страница 55: ...57600 115200 bps 02 Dial 9 Flag This parameter sets if a station can access an outgoing line by dialling 9 If this parameter is disabled the station can still access an outgoing line by pressing a line key at Key phone or dial 8xx xx is the trunk number IP Value 0 1 05 04 02 Dial 9 feature is enable Dial 9 feature is disable 03 Action for Call Duration Limiting This parameter decides what action w...

Страница 56: ...nable its total number will be dropped to 450 Please note that the personal speed dials are shared between all extensions To assign the number of personal speed for each extension refer to Mode 42 nnn DP IP Value Value Speed Dial Number Personal Total Name Feature 05 04 06 0 100 100 to 199 900 450 05 04 06 1 200 100 to 299 800 400 05 04 06 2 300 100 to 399 700 350 05 04 06 3 400 100 to 499 600 300...

Страница 57: ...ate industry standard neon light message waiting phones 1 Auto Ring If the setting is Ring the single line phone will receive 30 seconds intercom ringing every 5 minutes until the station answers 3 Special Ring 250 ms If the setting is 250 ms Ring the single line phone will receive two 250 ms ring burst every 5 minutes This is for use with the special telephones to turn on message lamp ...

Страница 58: ...ound Music or DND Tone 05 05 01 2 Voice Prompt of Morning Call Morning Call History Output via SMDR Port 05 05 01 3 Background Music or DND Tone Morning Call History Output via SMDR Port Each station can be set by Program 44 st 08 to decide whether to hear Background Music or DND tone To record Voice Prompt of Morning call Dial 89 Password Default 1234 2 3 3 from the console 02 Reserved 03 04 Spee...

Страница 59: ...s will be reduced See Program 05 04 06 Note 2 For setting name for Extension Speed dial Trunk Please refer to the Program 43 press MIC Note 3 For setting Directory Dial key Please refer to Program 07 06 Reserved 07 Auto Redial Trials This parameter is to set the number of Auto Redial trials that the system will attempt IP Value 0 1 2 3 4 5 6 7 8 9 Unit 05 05 07 0 2 5 9 19 29 39 49 59 69 times 08 A...

Страница 60: ...ansferring a call to a busy party and then transfer back to the original transferring party when the called party is busy IP Value 0 1 2 3 4 5 6 7 8 9 Unit 05 06 01 5 10 15 20 30 40 50 60 70 Sec Note Infinite It means never Recall 02 Transfer Idle Recall Time This timer defines the time duration for transferring a call to a idle station and then transfer back to the original transferring party whe...

Страница 61: ... 9 for C O line Dial 9 for operator 0 for C O line 06 Unsupervised Conference ECF Time Setting This timer defines the time duration that system allows an Unsupervised Conference or ECF External Call Forward to continue before sending a warning tone to the parties and then disconnecting the call If either party sends a DTMF digit 0 9 to the system the timer will reset and allow the call to continue...

Страница 62: ... the station hunting groups Pilot numbers for hunt groups are set in Program 67 Day Night ring stations are set in Program 68 69 Individual Hunt Group Ring type are set in Program 67 gp 02 and will over ride the system wide setting made here IP Value 0 1 2 05 06 08 Common Linear Circular ...

Страница 63: ...nal station which is busy or does not answer pressing 4 will call the next station which is in the same station group as the called station If setting is Disable then there will be no such searching IP Value 0 1 2 3 05 07 01 Disable Enable when busy Enable when no answer Enable when busy or no answer 02 Toll Override Prevention from Quick Dial To protect toll override control when a Key phone sele...

Страница 64: ...g a line a user will be able to use a DTMF generator directly to the network rather than the DTMF signal generated within the KSU The result of this is that Toll restrictions can be over ridden If the setting is Enable then no audio will be sent from the handset until 3 digits are received by the KSU from the key station dial pad preventing Toll restrictions being overridden This parameter will be...

Страница 65: ...call will go to the 3rd extension immediately All stations which have been called by the ring assignment will receive off hook busy remind Up to 26 stations can be set in the ring group If this setting is 0 then only the first ring assigned station will be ringed Related Program 35 tk 07 35 tk 08 IP Value 0 1 2 3 4 5 6 7 8 9 unit 05 08 01 Disable 2 4 6 8 15 30 60 120 254 sec 02 DSS Access to Other...

Страница 66: ...xx 2xx 3xx 4xx 5xx 6xx 7xx 7xx for programming 8xx for accessing functions beginning with 8 Note 1 0 Disable It means SLT has no programming capability 2 9 Disable and the means Redial function 06 DISA Transfer Time No Answer An incoming call is answered by Auto Attendant and transferred to the called extension If the called extension does not answer after this time duration a voice prompt will an...

Страница 67: ...3 SLT 02 7 SLT Music 43 SLT 02 7 SLT Music 43 SLT 02 7 05 08 08 5 External Music SLT Music 43 SLT 02 7 External Source 05 08 08 6 Internal Music Internal Tone Internal Music 05 08 08 7 External Music Internal Tone External Source Note 1 BGM Background music for internal extension only 2 MOH Music on Hold for CO line is put on hold 3 Door Set Door ringing as background music Program 05 03 08 9 4 In...

Страница 68: ... Signal CFS is a signal sent in the forward direction to terminate a call or call attempt so that the associated circuits can be released This signal is normally originated when the calling party hangs up the phone Some Central Office provides this kind of signal by breaking disconnecting the Loop circuit for a period of time and then making connecting again This Break time period is varied at dif...

Страница 69: ...time duration before the system answers an incoming call when the ring assigned station s are busy if the operator overflow feature is enabled The incoming call will show as a normal ring signal on the DSS key and can be answered by the operator at any time even while the voice message is playing to the caller Operator Overflow ACD 1 is enabled in Program 29 tk 02 IP Value 0 1 2 3 4 5 6 7 8 9 unit...

Страница 70: ...ing ACD 1 operation when it has not been answered by an operator The system will play a warning message to the caller before releasing the call If polarity reversal is used for incoming call clear down then this parameter should be disabled IP Value 0 1 2 3 4 5 6 7 8 9 unit 05 09 08 0 5 10 15 20 25 30 35 40 45 Mins ...

Страница 71: ...he system will insert additional digits if the Voice Mail requires more The last digits of the voice mail box number will still have to be the same as the station numbering for correct recognition The HOLD key can be used to insert a pause in the DTMF tone sending and will display as a p The DND key is no digits sent and is shown as d The possible value for each leading digit is 0 to 9 Pause enter...

Страница 72: ... Mail as usual but then monitor calls to the Voice Mail from his key phone on hook and if they wish can lift the handset and take the call back from the Voice Mail To enable the user presses SPK 7 7 3 1 and to disable presses SPK 7 7 3 0 Record Function This function is dependant on the Recording Unit being capable of inserting the recording tone to alert the caller they are being recorded To reco...

Страница 73: ...ll omit the start digit for CLI Caller ID data on the display phone and CLI list 02 Number of DISA Passwords This parameter defines the total number of DISA passwords At the default setting of 0 the DISA password will be set in mode 13 02 If the parameter is set to 1 there are 50 passwords available to use and they are same as the forced account codes numbers 50 99 Refer to Program 17 Forced Accou...

Страница 74: ...11 05 2 DISA caller can access an outside line by 9 or 0 Password DISA caller cannot access mail box or VM from external call by 05 11 05 3 DISA caller cannot access an outside line by 9 or 0 Password DISA cannot access mail box or VM from external call by Note 1 The password for DISA caller to make another outside is assigned at Program 13 02 2 Remote Access to retrieve messages outside the telep...

Страница 75: ... by 1 digit 1 8 using the Hunt Groups 01 08 settings in Program 67 Pilot No Ring 68 Day and 69 Night Lunch Program 05 16 03 to set second level menu for DISA Single Digit Dialing IP Value 0 1 2 3 4 5 6 7 05 11 08 DisableEnable Day Enable Night Enable Day Night Enable Noon Enable Noon Day Enable Noon Night Enable Noon Night Day ...

Страница 76: ...mal DK phone way to transfer a call is pressing Hold then dial Station Number pressing TRF key It also adds the ability to transfer a trunk call to another trunk External Call Transfer using the Transfer key rather than the Unsupervised Conference facility IP Value Value Description 05 12 01 0 DK phone way 05 12 01 1 Analog phone way 05 12 01 2 Note 3 05 12 01 3 Note 4 Note 1 DK phone way Hold Sta...

Страница 77: ...es Yes No No Yes Yes Leading Digit for VMS No Yes No Yes No No Yes No Short type Use the Leading Digit programmed in program 05 10 Long type Use Enhanced Protocol Mute Leading Digit The caller will not hear the DTMF signal during the transmission of leading digits Leading Digits for VMS Yes When incoming caller call the voice mail directly the system will send the Leading digits 7 CO trunk number ...

Страница 78: ...k In Check Out This parameter disables or enables the LED indication for Check in Check out features for the DSS consoles and DSS Keys of DK phones IP Value 0 1 05 12 07 Disable Enable The LED indications are as follows LED Description Red and slow flash If the Reception has checked out an extension the LED for extension will slow flash red Green When the checked out extension s room has been clea...

Страница 79: ...ey IP Value 0 1 05 13 01 Disable Enable Note 05 13 01 also controls the display upon plugging in a telephone system If set to 0 the telephone will display the extension number as soon as the telephone set boots If set to 1 the telephone will display the firmware version of the Lynx KSU when it is powered up 02 Immediate SMDR Output This parameter enables system to send out SMDR record when call is...

Страница 80: ...l display the date time the call took place 06 CTI Trunk Status Report Enabling this parameter will output the trunk status report for CTI applications Currently 4 is the correct setting for Ct Star applications IP Value 0 1 4 5 05 13 06 Disable Enable Enable Extension Status Report Enable Trunk Status report 07 Least Cost Routing Weekly Holiday 1 This parameter set the first weekly holiday for Le...

Страница 81: ...n use to prevent the SLT dialling from conflicting with the LCR dialling IP Value 0 1 4 05 14 01 Disable 3 seconds delay 6 seconds delay 02 Reserved 03 Reserved 04 Reserved 05 DISA DTMF Detect Delay Time This parameter defines the time delay for detecting DTMF signal on a DISA call after DISA answers IP Value 0 1 2 3 4 5 6 7 8 9 unit 05 14 05 0 1 2 3 4 5 6 7 8 9 sec 06 CLI Delay Ring Time This par...

Страница 82: ... 05 1 2 Reserved 06 1 0 Reserved 07 0 0 Reserved 08 0 0 Reserved Description 01 Company Greeting Time This parameter extends the company greeting 60 seconds of Auto Attendant by adding the department greeting 60 seconds Both greetings shall be recorded separately The system will bundle them together and make a seamless voice message IP 0 4 05 15 01 Company Greeting 60 seconds Company Department Gr...

Страница 83: ...vel IP Value Value Description 05 16 03 0 One level System plays VMU standard greeting after DISA answers the incoming call Users can dial either the extension number or the single digit service 05 16 03 1 Two levels When incoming call rings in to the system the external party will hear the Company Greeting to announce Press 1 to access different department by single digit service 05 16 03 2 Two l...

Страница 84: ...ss 8 to select second language service 05 16 04 9 Play 1 st Language then play 2 nd Language service 05 Reserved 06 Reserved 07 ACP Data Output Format This parameter chooses the output format of ACP data The format can be plain text or CTI format IP value Value Description 05 16 07 0 CTI format output to RS232 05 16 07 1 ACP accessing data will be stored in system 800 max records 05 16 07 2 CTI fo...

Страница 85: ...e For customers who want to increase the recording capacity this parameter allows the compression rate to be 16 KBPS That will double the available amount of storage time on the VMU while voice quality will be decreased In the new version of 1GB VMU2 there is no voice compression and message is 64K uncompressed IP Value 0 1 05 17 02 16K bps 32K bps 03 Extension Number Announcement for DISA The Aut...

Страница 86: ...t ringing assigned stations 1 9 Incoming trunk connects to Auto Attendant or another trunk after 2 254 seconds ringing Also see Program 05 01 04 for Day and Program 05 11 4 for Night mode 05 DTMF CLI Leading Digits This parameter enables disables the display of Leading digits on DTMF Call ID IP Value 0 1 2 3 4 5 6 7 05 17 05 No code A B C D Note 1 Note 1 Only display the normal digits 0 1 2 9 2 Ex...

Страница 87: ...ll be transferred to the virtual voice mail 41 If there is CLI information and the CLI is matching with the call blocking number that is assigned at Mode 09 the call will be transferred to the virtual voice mail 41 or 42 or 43 or 40 that is LED flashing without ring Note 1 If the VMC is not installed the call will not be transferred to the virtual mail 41 And the LED of that CO line DSS key will b...

Страница 88: ... of an SLT extension line this will trigger an Alarm Ring signal to the console with the LCD message as follow If a user lifts the handset to make an emergency call but can t talk for some reason usually health related after 2 minutes the console will receive an Alarm Ring with the LCD message as follows IP Value 0 1 05 18 02 Disable this feature Enable this feature Note Extension that need this f...

Страница 89: ...CF External Call Forwarding voice announcement to an incoming caller when they are being transferred to an external telephone number by the system IP Value 0 1 05 18 06 Disable Enable 07 High Frequency Level of DTMF Generator This parameter modifies the level of the High frequency DTMF Generator This should not be modified under any circumstances IP Value 0 1 2 3 4 5 6 7 8 9 unit 05 18 07 16 8 2 1...

Страница 90: ...or VMU 05 0 1 NZ Distinctive Ring Selection Australia or New Zealand 06 0 0 Reserved 07 0 0 Reserved 08 0 0 Reserved 01 Reserved 02 Reserved 03 Reserved 04 Silence Detection For VMU This parameter enables Silence detection for the Voice Mail to disconnect a call after receiving this period of silence from the caller IP Value 0 1 2 3 4 5 6 7 8 9 unit 05 19 04 Disable 10 20 30 40 50 60 70 80 90 sec ...

Страница 91: ...er disconnect the caller or transfer the caller to the appropriate operator as programmed on 05 07 04 A setting of 1 through 6 will route the caller to one of the six virtual extensions in the system so that the caller can leave a message Note By default only the first two Virtual extensions are configured with mailboxes 1 Virtual mailbox 41 2 Virtual mailbox 42 3 Virtual mailbox 43 4 Virtual mail...

Страница 92: ...eive mailboxes 05 06 07 08 8 ports on expansion card extension 15 18 and extensions 23 26 receive mailboxes 09 10 11 12 13 14 15 16 4 Virtual stations extensions 41 42 receive mailboxes 17 18 19 20 04 Reserved 05 Reserved 06 Reserved 07 Reserved 08 Reserved ...

Страница 93: ...ay Programming Data Timing Pointer Data Description Table Default 01 0 Reserved 0 02 0 Reserved 0 03 0 Reserved 0 04 0 Reserved 0 05 0 Reserved 0 06 0 Reserved 0 07 0 Reserved 0 08 0 DSP Reset Reserved 1 Description 01 Reserved 02 Reserved 03 Reserved 04 Reserved 05 Reserved 06 Reserved 07 Reserved 08 DSP Reset Reserved 0 Disable 1 Enable DSP in act 480 m s ...

Страница 94: ... 01 Reserved 02 Reserved 03 Reserved 04 LYNX Monitor System Tracking This parameter enables the LYNX monitor system and handset tracking features 0 Disable 2 enable monitor Tx to DK phone trace 3 enable monitor Tx to DK phone trace 4 enable monitor SWITCH ACTION trace 5 enable monitor SWITCH ACTION trace 6 enable monitor SWITCH ACTION trace monitor Tx to DK phone trace 7 enable monitor Tx to DK ph...

Страница 95: ...odec download External program 3 enable monitor DSP trace monitor DSP Write Codec download External program 08 LYNX Monitor VMC Trace This parameter enables disables the LYNX monitor VMC Voice Mail Card trace 0 Disable 1 enable monitor VMC trace 2 enable monitor VMC R W CF card pointer table download External program 3 enable monitor VMC trace enable monitor VMC R W CF card pointer table download ...

Страница 96: ...acts and will close on activation of the function for which they have been programmed When the St is 000 it means the relay on the motherboard When the St is a valid station number it is the relay on the ACP corresponding to that station number Assign the required Relays to one of the following functions Item Value Function 00 No Operation 01 Music On Hold 02 Door open 03 Reserved for future use 0...

Страница 97: ...SS key number FN Function Number ff General This program assigns 8 groups of Flexible key plans for Key phones Each Key phone can be assigned two groups of functions Refer to Program 41 st 02 03 Description Each key can be assigned as Trunk Station or Special Function To change the assignment from TK to Station or to Function or vice versa press the Change MIC AT key before setting nn 01 12 Trunk ...

Страница 98: ... 41 Loop Key Group 4 42 Loop Key Group 5 43 Loop Key Group 6 44 Loop Key Group 7 45 Loop Key Group 8 46 Toll Password 47 Alarm Assign 48 User Alarm 49 Console User Alarm 50 Console Set up System Time 51 Reserved 52 Day Night 53 Call Forward 54 Forward Busy 55 Forward No Answer 56 Meet me Page 57 Shift Key 58 Reserved 59 Hotel Motel Function 60 Door Phone 61 Security System 62 Directory key for nam...

Страница 99: ...ure a Set Call Forward to station 86 that is your voice mail box number for your keyphone b Press FN 27 key will enable the Answering machine Emulation feature c Press FN 27 key again will disable the Answering Machine Emulation feature Note 1 When activated this function allows the caller to set call forward to the Voice Mail as usual but then monitor calls to the Voice Mail from his key phone on...

Страница 100: ... VMC must be installed to allow Call Blocking transfer to Virtual Voice Mail to be enabled Call Blocking is enabled in Mode 05 17 07 Press the MIC AT Change key twice to change or clear the settings for CLI Call Blocking Pre Assigned CO Line Press the MIC AT Change key to change or clear the Pre assigned CO line number This CO line is the dedicated outgoing line for the speed dial code If the user...

Страница 101: ...t could be the Auto Attendant or Voice Mail ii Flash This will make a loop disconnection of a pre assigned duration Refer to Program 05 02 05 iii Pulse to DTMF If the dialled signal is pulse it will change to DTMF Note Pressing DND Don t Care will erase the digit which the cursor is on Pressing REDIAL CLR ALL will erase all the assigned digits Associated program 05 05 05 05 04 06 05 17 07 43 51 05...

Страница 102: ...in this Program shall be enabled by Single Digit Intercom Refer to Program 05 04 07 Description When single digit intercom is enabled then the pre fix digit 6 of station to station call must be dialled to call another extension If a particular group has no entries programmed the stations in the same number station group will not have single digit dialling and will not have to use the station to st...

Страница 103: ... each Item IP Value Item Description 11 01 01 12 Month 11 02 01 31 Day 11 03 00 99 Year 11 04 00 23 Hour 11 05 00 59 Minute 11 06 1 7 Week day Monday 1 Tuesday 2 General This program set up the system s Date Time Description The Date Time will be held during power failure of LYNX plus There is no need to reset the Date Time after power is restored ...

Страница 104: ... Data Description hh 00 23 Hour mm 00 59 Minute dd 00 99 Duration General This program permits the assignment of 10 time schedules for alarm clock purposes Description When the assigned time is reached Background music will be broadcast over all idle Key telephones The time duration for alarm clock music is programmable 00 to 99 minutes ...

Страница 105: ...n Password Description 1 Programming Password Default is None 2 DISA Password 3 Toll Free Default is 8655 4 DISA Monitor Default is 1234 5 Reserved 6 Silent Alarm password 7 VMU Password Default is 1234_ _ _ _ 8 Reserved 9 Reserved Note 1 DISA Password The password is for DISA caller to access another CO line by DISA Refer to Program 05 11 05 DISA Special Function Access Default is 3472 version of...

Страница 106: ...tail Recording parameters 01 Call Duration Start Time This parameter defines the minimum access time to start recording the SMDR IP Value 0 1 2 3 4 5 6 7 8 9 unit 14 01 01 0 5 10 15 20 25 30 35 40 45 sec 02 Record Incoming Calls This parameter decides whether incoming calls are recorded or not IP Value 0 1 14 01 02 Record Do not Record 03 Record Local Calls The parameter decides whether local call...

Страница 107: ... SMDR format output 14 01 08 1 PR Detection Normal SMDR format output 14 01 08 2 No PR Detection Simple SMDR format output 14 01 08 3 PR Detection Simple SMDR format output SMDR OUTPUT DATA FORMAT ST TK S TELEPHONE NUMBER Account MM DD START DURATION RING UNIT 112 01 001188629645752 12345678 10 02 08 35 00 02 35 115 02 Incoming 87654321 10 02 08 45 00 10 20 00 10 000 03 Incoming no answer 10 02 12...

Страница 108: ...the call 8 The held line 1 was answered by station 117 and he occupied the line for 3 minutes and 10 seconds Four meter pulses were recorded against this station for its section of the call 9 Incoming Line 3 using the DISA function made an outside call 018220212 on line 5 The Duration time is for line 5 3 meter pulses were recorded for this call 10 DISA is completed The Duration time is for line 3...

Страница 109: ...by station basis to select whether calls to that station will display the In dial number dialled or the CLI information of the incoming caller 3 An incoming call rang for 35 seconds and no one answered The CLI number of the calling station is displayed 4 An incoming call on line 5 ISDN was answered by station 111 The SMDR displayed the CLI number 294150100 of the calling party The system can be pr...

Страница 110: ... will not be displayed on the screen of Executive phones when it is entered Digit d is keyed in by DND CN button and means Any digit don t care Digit _ is keyed in by TRF FL button and means No digit Clear all digits by pressing TRF FL to insert a line in place of the original entry The last two digits dd are for toll class selection Day and Night The forced account code will open the call from th...

Страница 111: ... on lines 5 to 10 Example 2 Program Mode 18 01 is set to 111100dddd Any station in the system which is set to toll class 1 will be restricted by toll class 1 on lines 1 to 4 will be unrestricted on lines 5 and 6 but will be unable to dial out on lines 7 and 10 To assign toll plans to stations see Program 41 st 05 41 st 06 Toll Classes Class Function Prog Mode 0 Unrestricted Default 1 Use Mode 51 f...

Страница 112: ...ge between Automatic and Manual switching The meaning of nn as follow 00 Sunday 01 Monday 02 Tuesday 03 Wednesday 04 Thursday 05 Friday 06 Saturday Example 20 01 Day Time 08 30 17 00 12 20 01 Day Time 30 13 30 On Monday the system will switch from Night time to Daytime start at 8 30 in the morning will switch to lunchtime start at 12 30 switch back to daytime at 13 30 and switch to Night time at 1...

Страница 113: ...tricted This feature is for Hotel Motel operation After setting this Mode it is necessary to reprogram the Console and any Administration phones in Mode 44 st 02 to allow them to place calls on hold 4 For all Stations 40 st 01 0 Barge In not allowed 40 st 02 0 Monitor not allowed It is strongly recommended that this parameter is used on ALL systems to prevent accidental Barge In operations being m...

Страница 114: ...rameter will allow Receive loudness to be boosted IP Value 0 1 2 3 4 5 6 7 8 9 unit 29 01 01 0 1 2 3 4 5 6 7 8 9 db 02 ACD 1 Function Enable This parameter enables or disables the ACD 1 function for each trunk individually and is able to select whether ACD 1 operates in Day or Night or Both Modes IP Value Day Time Night Time 29 tk 02 0 Disable ACD function Disable ACD function 29 tk 02 1 Disable A...

Страница 115: ...ing assigned in Program Mode 01 or 02 to receive the audible ring signal when a trunk rings at the station If the audible signal is disabled the station will still be able to answer a call by lifting the handset only if they are ring assigned in Program Mode 01 or 02 0 All stations assigned in Mode 01 02 will receive audible signal for an incoming call 1 Only the first station assigned in Mode 01 ...

Страница 116: ...unit 29 01 07 Disable this feature 8 16 24 32 40 48 56 64 72 sec Related System Programming Mode 29 Tk 07 29 Tk 08 67 68 69 08 CO Delayed Ring Overflow Hunting Group This parameter sets the pre assigned overflow Hunting Group for an incoming call If the stations in the Ringing Line Preference Assignment Mode 01 02 do not answer the incoming call within the pre assigned timing Mode 29 TK 07 the cal...

Страница 117: ...ts each trunk line to be assigned to different parameters Description 01 Trunk Type CO PABX IP Value Value Description 35 tk 01 0 Trunk line is Central Office line 35 tk 01 1 Trunk line is installed behind a PABX or Centrex When user makes a Redial Call system will automatically add if trunk line is installed behind PBX or delete If trunk line is Central Office line a leading digit 0 or 9 that is ...

Страница 118: ...xternal Call Forward DISA ECF must be enabled during the time period to be utilized They may be enabled during day service only or night service only or both day and night service or may be disabled at all times The table below shows the valid setting and the resulting status IP Value Day Night 35 tk 04 0 DISA ECF Disable DISA ECF Disable 35 tk 04 1 DISA ECF Disable DISA Enable 35 tk 04 2 DISA Ena...

Страница 119: ...sition and provide an overflow capability so that backup answering stations can be automatically added as necessary If an incoming line rings an extension which is busy or does not answer within the assigned Hunt Time Program 05 08 01 the call will ring the next available extension assigned in the hunt group Up to 16 If the next ringing station is busy then the call will immediately move to the ne...

Страница 120: ...R 35 tk 08 3 Night HUNT 35 tk 08 4 Night PRIVATE To set a trunk name 1 Enter system programming Mode 35 2 Pressing MIC Change to enter the Name mode 3 Input the name for the related trunk by the following function keys Key Pad Depress 1 time Depress 2 times Depress 3 times Depress 4 Times Depress 5 Times 1 1 Space 2 A B C 2 3 D E F 3 4 G H I 4 _ 5 J K L 5 6 M N O 6 7 P Q R S 7 8 T U V 8 9 W X Y Z ...

Страница 121: ...ng calls to start from the highest fitted trunk and program in descending order to the lowest trunk fitted This will prevent call collision particularly in systems with SLT S using PSTN trunks An additional 8 groups are available by utilizing the groups available in Mode 38 for the dial 87 trunk groups If a station is allocated no dial 9 0 group in Mode 41 st 04 but is then allocated a Dial 87 gro...

Страница 122: ... feature is used when the user does not want to use the trunk or to remove a problem line When the trunk is set to BUSY OUT the LCD display on the phone will display Access denied when that line button is pressed Value Item Description 0 Line is unlocked 1 Busy for Outgoing calls 2 Busy for Incoming and Outgoing calls set loop on 3 Busy for Incoming and Outgoing calls set line LED on ...

Страница 123: ...ead of it s dial 9 group Always set outgoing calls to start from the highest fitted trunk and program in descending order to the lowest trunk fitted This will prevent call collision particularly in systems with SLT S Press REDIAL to clear all entries in the table before entering required trunks Description This program is different from Program Mode 36 gp tk This program is used for dialling 87 or...

Страница 124: ... be assigned to one of the following 18 functions FN Function 00 No Operation 01 Fire Alarm 02 Break Alarm 03 Door Phone 1 04 Reserved for future use 05 Security feature 06 18 Reserved for future use The valid sensor types for sensor on the motherboard S Item Description 0 Disable Sensor function 1 Normally Open for night 2 Normally Closed for night 3 Normally Open day 4 Normally Closed Day 5 Norm...

Страница 125: ...t Class of Service Description 01 Override Level Higher level stations can override lower level stations equal levels may override each other and lowest levels may not override each other IP Value 0 1 2 to 8 9 40 stn 01 Disable Lowest level Highest level 02 Monitor Level Higher level stations can monitor lower level stations equal levels can not monitor each other IP Value 0 1 2 to 8 9 40 stn 02 D...

Страница 126: ... who does not want to be disturbed by paging calls 07 Security Code Status IP Value Default 40 stn 07 0 The station is unlocked Can make outgoing calls 40 stn 07 1 The station is locked Can not make outgoing calls If a phone becomes locked accidentally or the user forgets their lock code this parameter will unlock the phone There is no way of finding what the lock code was 08 Forced Account Code W...

Страница 127: ...Group IP Value Value Description 41 stn 01 0 Disable 41 stn 01 1 8 Group 1 to 8 To select the station group for this station 02 Flexible key group assignments for Key phone This parameter assigns stations to one of 8 flexible key groups IP Value Value Description 41 stn 02 0 Disable 41 stn 02 1 8 Key Group 1 to 8 See Mode 07 Flexible key group assignment for key phone 03 Shift Key Group for Key ph...

Страница 128: ...locate which trunk group will use this port as a MOH source The current drawn from the SLT port MUST be limited to no more than 10ma to prevent damage A line isolator will achieve this IP Value Value Description 41 stn 04 0 All Trunk groups 41 stn 04 1 8 Trunk group 1 to 8 Related System Programming Mode 36 38 41 ST 04 46 ST 01 05 Toll plan Day This parameter assigns the toll plan to be used by th...

Страница 129: ...Codes 00 09 shares the same memory block with DSS11 DSS20 Each Station can use up to 2 blocks 20 sets of Individual Speed Dial If names are enabled then the number of blocks available is half Example 42 13 IP SPD T 01 02 13 Station No 2 4 digits 01 02 Station 553 can use block 01 and 02 for Individual Speed Dial 20 sets 42 15 IP SPD T 04 00 15 Station No 2 4 digits 04 00 Station 105 can use block ...

Страница 130: ...s Description 01 Station Number Use this setting to assign station numbers for the Flexible Numbering Plan The allowed number range is 10 69 100 699 1000 6999 If it is necessary to use digits 7 or 8 as part of the station numbering scheme then Mode 05 08 05 must first be set to 8 to prevent confusion between control codes programming digits and Station numbers 02 Equipment Type IP Value Value Desc...

Страница 131: ...l to provide more information to the Voice Mail unit see Mode 05 10 for descriptions of the protocols available 6 Type 9 allows the ISDN Basic Rate to be made an S bus 51 52 the 1st Internal ISDN port of the 1st LYNX SIU card and the default extension number is 141 142 53 54 the 2nd Internal ISDN port of the st LYNX SIU card and the default extension number is 143 144 55 56 the 3rd Internal ISDN p...

Страница 132: ...ion of the display When you press the MIC key the lower portion of the display disappears and you may now enter the name using the letters associated with the keys 43 11 06 Port 1 Enter system programming Mode 43 2 Press MIC to enter into the Name mode 3 Input the name for the related extension by the following function keys 4 As each letter is satisfactorily entered press DSS button 4 to move the...

Страница 133: ...ceive system alarm clock signals IP Value Value Description 44 stn 01 0 The System Alarm signal will be received on this station 44 stn 01 1 The System Alarm signal will not be received on this station 02 Hold Feature If the setting is disable the station will not be able to place calls on hold IP Value Value Description 44 stn 02 0 Hold function allowed 44 stn 02 1 Hold function not allowed 03 Ca...

Страница 134: ...mode is disabled the user cannot switch between handset and headset mode IP Value 0 1 44 stn 05 Disable Enable 06 Use Engineering Password If the setting is disable the station is unable to use the engineering password to enter programming mode IP Value 0 1 44 stn 06 Disable Enable 07 Reserved 08 Station Alarm Signal This parameter decides what signal the station will hear when a station alarm or ...

Страница 135: ...tion s SMDR Data General This program permits each station to be assigned to a different Class of Service Description 01 Intercom Call Limitation If this setting is enabled the station can not make an intercom call by dialling a station number Under this condition the Key Phone still can press a Flexible Key to make an intercom call or the Key Station or Analog phones can call a station using the ...

Страница 136: ...39 IP Value 0 1 45 stn 06 Enable Disable 07 Allow Unrestricted Speed Dial Access If this parameter is disabled then the station will not be able to access any of the Speed Dial numbers which have been unrestricted in Mode 05 05 03 04 if they conflict with the stations toll restrictions IP Value 0 1 45 stn 07 Enable Disable 08 Record Station s SMDR Data If this parameter is disabled then calls to a...

Страница 137: ...her levels can leave message for stations with the same or lower levels Ten levels 0 9 are available 9 highest level 0 lowest level Stations which are set to 0 can not send a message waiting information but only receive a message waiting from the voice mail unit IP Value Value Description 46 stn 02 9 Can do Message Waiting to Stations that are assigned level 0 9 46 stn 02 8 Can do Message Waiting ...

Страница 138: ...swers the call Using this Settings 5 to 7 the call will ring the station for 1 cycle Mode 05 08 06 and then recall to the console and cease to ring the called station If the parameter is set to 0 then the call will stay at the station until answered or terminated If the extension is a Fax or Modem on ISDN DID then the setting must be 4 to prevent Fax or Modem calls being sent to an operator if the...

Страница 139: ... allocates the Station Hunt Group that the ACP will call if it is programmed as a Door Phone and the Call button is pressed When setting is d the ACP will call the extension according to the assignment in Program 3 Door Phone Ring Assignment If the Extension is not an ACP then this parameter sets the Permanent Call Forward destination Hunt Group on No Answer If the Station user sets a Call Forward...

Страница 140: ...tion No 3 digits Speed Dial 101 for example 94150100 When the user lifts the handset the System will automatically call 9425010 through System Speed Dial 101 2 Press MIC to select a hot line Intercom Press again to go back to SPD assignment the display shows 47 115 HOT LINE 00 Enter an Extension number 118 47 115 HOT LINE 118 The system calls Extension 118 when the handset is lifted The Hot Line i...

Страница 141: ...its each station to be assigned to a different Class of Service Description 01 Reserved 02 Reserved 03 Group Listen Feature This parameter enables disables the Group listen feature that is available on some versions of DK2 and DK6 handsets When DK phone is operated on Group Listen feature user places the handset back to the cradle user may hear the oscillation noise on the speaker Pressing MIC key...

Страница 142: ...ion Hotel Alarm Type General This program permits each station to be assigned to a different Class of Service Description 01 ACP Warning Signals This Parameter enables the warning signals for the ACP RFID unit The warning signals are ACP s Case Breaking Alarm and Unplug Alarm IP Value 0 1 50 stn 01 Disable Enable 02 Call Forward Indication This feature will disable the flashing SPK key on a handse...

Страница 143: ...er can select MBU s relay or ACP relay as Door unlock relay If the MBU s relay is enabled then both the ACP relay and the MBU s relay will operate for that door phone This will allow a more secure door opening method when multiple ACP and Door unlocking are used IP Value Value Description 50 stn 06 0 Use ACP relay 50 stn 06 1 Use LYNX MBU s Mode 06 00 needs to be assign to 2 and ACP relay Related ...

Страница 144: ...o make intercom calls or outside line calls The ACP works as a handsfree key phone When the extension is an SLT phone this paramateri enables the Hotel Alarm as follows IP Value Value Description 50 stn 08 0 Disable Hotel Alarm 50 stn 08 1 Enable Hotel Alarm Description Hotel Alarm When the Hotel guest lifts up his SLT phone without dialing for more than 2 minutes the hotel console will be rung an...

Страница 145: ...sses Class Function Prog Mode 0 Unrestricted Default 1 Use Mode 51 for the Unrestricted numbers Use Mode 61 for the Restricted numbers Mode 51 61 2 Use Mode 52 for the Unrestricted numbers Use Mode 62 for the Restricted numbers Mode 52 62 3 Use Mode 53 for the Unrestricted numbers Use Mode 63 for the Restricted numbers Mode 53 63 4 Use Mode 54 for the Unrestricted numbers Use Mode 64 for the Restr...

Страница 146: ...dial the full number Modes 51 to 56 are used in conjunction with Modes 61 to 66 and Modes 57 to 59 are used independently and do not have an associated restriction table In Default stations which are allocated Toll Plans 0 to 6 are able to dial any numbers When a station is allocated Toll Plans 7 to 9 they can dial no digits until the plans are programmed Mode 51 and 61 combine to produce Toll Pla...

Страница 147: ... 9ddddddddddd Station 11 will now be only able to dial numbers beginning with 8 and 9 To allow mobiles program Mode 51 to the following Mode 57 03 04dddddddddd Example 2 All calls except ISD and 19 numbers Set Mode 41 11 05 06 1 When this mode is set and Mode 51 and 61are still at default then station 11 will be unrestricted Set Mode 61 to the following Mode 61 01 00dddddddddd Mode 61 02 19ddddddd...

Страница 148: ...stations in the group according to the ringing method selected and the order in which they are programmed in Mode 68 Day and Mode 69 Night Each Hunt Group can be from 1 to 16 stations There are 3 types of Ring available Common Linear and Circular If Common Ring is enabled then calling the pilot number will always ring all available stations in which they are programmed in Mode 68 or 69 If Linear R...

Страница 149: ...r Hunt Group for instance Voice Mail Group then only direct calls to the station will be forwarded If Hunt calls come to the station and it is call forwarded it will still ring for the call for settings 0 1 2 but will follow CFW setting of first station if set to 4 5 6 Related System Programming Modes 05 06 08 67 68 69 ...

Страница 150: ...e Linear and Circular If Common Audible is enabled then all stations will ring simultaneously If Linear Ring is enabled then calling the pilot number will always call the first available station in the order in which they are programmed in Mode 68 or 69 If Circular Ring is enabled then the stations will be called one after the other for each succeeding call until all have taken a call and then the...

Страница 151: ...Night time There are 3 types of Ring available Common audible Linear and Circular If Linear Ring is enabled then calling the pilot number will always call the first available station in the order in which they are programmed in Mode 68 or 69 If Circular Ring is enabled then the stations will be called one after the other for each succeeding call until all have taken a call and then the Ring will r...

Страница 152: ...ity to make certain that this route is not blocked Even if a number is not to be modified or rerouted in any way it should be allocated in Mode 75 to go to a route table in Mode 76 which will allow it to select a trunk and dial out using default settings Call flow is as follows A call is analysed in mode 75 and sent to mode 76 In mode 76 if the call is to be handled the same 24 hours a day then it...

Страница 153: ...n be used for normal operation plus 20 for the first holiday and another 20 for the second holiday 3 time schedules can be assigned for each routing table 4 priority trunk groups can be assigned for each routing table If there is no trunk group assigned here system will use Dial 9 trunk group instead 4 modifying tables can be assigned for each routing table For weekly holiday 1 system will refer t...

Страница 154: ...hanging the dialled number to the routed number Description The system will delete the first nn digits if required and then add the assigned digits in front of the dialled numbers Up to 10 digits can be assigned to be inserted The added digits can be 0 9 p T d is the wildcard is no digit p is the pause character T means to chain to next modifying table with current one for long digit strings Relat...

Страница 155: ...ation to use the 1 st 4 th priority trunk groups 78 stn 01 5 Allow this station to use the 1 st 4 th priority trunk groups If there are no available trunks in the 1 st 4 th priority trunk groups the system will allow this station to use normal dialling Related system Programming 05 13 07 05 13 08 75 76 77 78 st 01 78 st 02 02 LCR Direct Access a Trunk This parameter assigns the right of the statio...

Страница 156: ...System will only use one CO line to activate the notification function at a time IP Value Value Description 78 stn 05 0 Disable the notification 78 stn 05 1 Dial the specified number 3 times to notify the user 78 stn 05 2 Dial the specified number 6 times to notify the user 78 stn 05 78 stn 05 9 Dial the specified number until the user answers and enters correct password Note 1 The telephone numbe...

Страница 157: ...e This parameter sets whether an extension will answer a trunk ringing at that extension by lifting the handset or will need to press the DSS key of the ringing trunk or use pickup if the trunk is not displayed IP Value 0 1 78 stn 04 Auto Answer Manual Answer 08 Reserved ...

Страница 158: ...use up to 2 blocks The next assigned block must be null or continuous after the first assigned block number for each extension That means if the first assigned block number is n then the next assigned block must be 0 null or n 1 Example Mode 05 13 03 0 83 113 IP CLI T 01 02 13 Station No 2 4 digits 01 02 Station 113 can use block 01 and 02 for CLI history buffer and it could store 20 sets 10 10 Mo...

Страница 159: ...d number is 2 80710002 If you have set mode 84 as above system will delete 2 and dial 80710002 for smart redial When analog PSTN line rings in to LYNX system the received number is 02 29645752 If you have set mode 84 as above system will delete 02 and dial 9645752 for smart redial When ISDN rings in to LYNX system the received number is 3 80710001 If you have set mode 84 as above system will add 0...

Страница 160: ...ed an entire area code Instead of separating portions and assigning unique area codes to different geographic regions the Telco has instead introduced an overlay area code This program assigns 5 sets of overlay area code for CLI redial feature Description The overlay area code is 3 digit format 5 sets of overlay area code can be assigned for the CLI redial feature ...

Страница 161: ... NXX XXXX Local Toll 1 7 Digit 2 Redial pattern is 1 NXX NXX XXXX Local Toll 1 10 Digit Retrieve the CID number from the history buffer Area Code Home Area Code Office Code s Pattern 1 Local Toll 1 7 digit Office Code s Pattern 2 Local Toll 1 10 digit Action C Dial 1 NXX XXXX Case 4 Action D Dial 1 NXX NXX XXXX Case 5 Action A Dial NXX XXXX Case 1 2 Area Code Overlay Area Code Action B Dial NXX NX...

Страница 162: ...ds RFID can be used on which ACP port to unlock a door Description Before a key card can be used to operate a door relay it must be set to be allowed in this program mode A key card can be enabled to unlock more than one door if multiple ACP s are fitted IP Value Value Description 0 Denied entry 1 Allowed entry Location MBU STU 1 STU 2 Extension port No 11 18 21 28 31 38 ACP port No 1 8 9 16 17 24...

Страница 163: ...to it Once the key card is registered then it will be necessary to proceed to mode 87 to allow the key card to open the door relay associated with the ACP To register a key card enter the station number of the ACP Register Card ST 115 Press SAVE Wait Registering Slide please Place the Key Card over the Speaker position on the ACP and when the ACP beeps remove the Key card and press SAVE Register S...

Страница 164: ... system Description Enter the number 01 99 of the key card to de register De Register Card Card 01 Press SAVE 89 01 01 Serial FFFFFFFF Press REDIAL to clear the digits 89 01 01 Serial 00000000 Press SAVE and the LCD display will move on to the next Key card number 89 02 01 Serial 00000000 FFFFFFFF Means Card was registered 00000000 Means Card was deregistered ...

Страница 165: ...e ACP time lock Cards assigned in such programmed period can be used to open the ACP door Description The first 4 digits are starting time and the last 4 digits are stopping time There are a total of 16 schedules which can be assigned 91 00 Table 08 30 17 30 Press SAVE means time schedule 00 is from 08 30 to 17 30 91 01 Table 21 00 22 00 Press SAVE means time schedule 01 is from 21 00 to 22 00 ...

Страница 166: ...rd Number 01 99 General This program assigns different ACP time lock schedule for ACP Cards assigned in such programmed period can be used to open the ACP door TM 00 15 Mode 91 Description 92 06 01 Card In 02 Press SAVE means card 06 use ACP time lock schedule 02 mode 91 02 ...

Страница 167: ...ecified here Up to 20 numbers of 5 digits each can be programmed If the whole 5 digits are not specified the Don t Care symbol must be entered to the end of the line as usual Mode 93 123456 AA BB Hotel 4 CC DD The formula of Call Charge is If BB is not set to 0 Call Charge Round TT BB x AA x CC x DD If BB is set to 0 Call Charge AA x CC x DD Where AA Cost per Unit BB Seconds per Unit CC Server Rat...

Страница 168: ...01 x 4 x 0 01 1 56 The Mini Call Accounting output will be 07 09 05 38 ROOM 11 TK DATE TIME DURATION TELEPHONE NUMBER UNITS COSTS 01 07 09 05 36 00 00 07 812345678 000022 000000 88 01 07 09 05 37 00 01 18 823456789 000022 000000 88 01 07 09 05 40 00 03 50 0918123456 000100 000004 00 01 07 09 05 27 00 01 12 0918654321 000050 000002 00 01 07 09 05 31 00 03 50 412345678 000039 000001 56 TOTAL 000233 ...

Страница 169: ...nswer ring the next ring assigned station then the next etc or COMMON AUDIBLE All stations will ring simultaneously See Program Mode 35 tk 08 to assign The LYNX Lunchtime ring type will follow the night ring type An overflow Ring Hunt Group can be assigned to make additional stations ring after a time interval in addition to this ring assignment See program Mode 29 07 08 The ringing stations will ...

Страница 170: ...ely If set to 2 or higher the system will delay playback of Auto attendant greeting to give the FAX detection clean audio to allow detection of incoming CNG tone If set to 0 and no FAX tone is detected the call will proceed according to system programming to processing of a voice call Definition of parameter IP Value Value Description 95 tk 01 0 The trunk won t detect the fax signal 95 tk 01 1 Tru...

Страница 171: ...is necessary to select the correct country settings in Program 05 19 05 The default setting is for New Zealand IP Val ue Normal Ring is detected ring the following extensions 2 nd Ring Type is detected ring the following extensions 95 tk 06 0 Program 01 tk 01 to 16 02 tk 01 to 16 Program 01 tk 01 to 16 02 tk 01 to 16 95 tk 06 1 Program 01 tk 01 to 14 02 tk 01 to 14 Program 01 tk 15 to 16 02 tk 15 ...

Страница 172: ... DUET Ring Select and Assignment Outgoing Calls Dial 9 IP Item Description 05 04 02 Dial 9 Enable Disable 05 06 05 Operator Code 9 0 36 grp tk Dial 9 0 Group Assignment 38 grp tk Dial 87 Group assignment 41 stn 04 Stations Dial 9 0 Group Assignment 46 stn 01 Stations Dial 87 Group Assignment PABX Outgoing Code 05 03 04 Code for outside line in PABX If trunk trunks are served by PABX Trunk Specific...

Страница 173: ...o Redial Attempts Quantity 05 05 08 Auto Redial Time Inter Call between attempts Intercom Calls Intercom Call Signalling 5 3 3 Intercom call signalling to electronic telephone sets 46 st 03 Automatic MIC switching Step Call 05 07 01 Intercom Step Call Type 41 stn 01 Station Group Assignment Dial Tone Pattern 05 03 07 SLT Dial Tone Pattern Options 05 04 07 Intercom Single Digit Dialling Single Digi...

Страница 174: ...lind transfer Camp On Busy 05 06 02 Transfer Recall Timer blind transfer No Answer 05 08 06 DISA No Answer Recall To Message Timer 05 08 07 DISA Transfer Time No Digits Dialled Message Waiting Level 46 stn 02 Message Waiting Level Override 40 stn 01 Override Level DISA IP Item Description 05 01 04 Delayed DISA Access Time Day 05 07 04 DISA Recall Capability 05 08 04 DISA Operator Recall Location N...

Страница 175: ...y Groups 41 stn 03 Assign Shift key group to stations Dial 9 0 Trunk Groups 36 grp trk Assign trunks to groups for Dial 9 0 41 stn 04 Assign stations a Dial 9 group Dial 87 Trunk Groups 38 grp trk Assign trunks to groups for Dial 87 46 stn 01 Assign stations a Dial 87 group Group Assignment for stations Page Zone Pick up Single digit 41 stn 01 Assign stations to station groups Call Control Toll Re...

Страница 176: ...rd for Monitoring over DISA default none 13 07 VMU Password 13 09 LCR Password Station Lock Unlock 40 stn 07 Station Lock Unlock Status Busy out a trunk 37 tk x Taking a trunk out of service Intercom Dialling restrictions 45 stn 01 Restrict station to station intercom dialling System Clock Date and Time Setup 05 04 04 12 24 hour time format 11 Set system time 20 nn Day Night schedule Definition Sy...

Страница 177: ...40 stn 05 Station Paging Access 40 stn 06 Receive Page Over Speaker 41 stn 01 Station Page Group Call Forward No Answer Transfer Time 05 01 08 Call Forward No Answer Timer Hot Line 09 spd nn System Speed Dial number for Hot Line use 47 stn xx Hot Line destination for a station Optional Services Door phone Door switch 03 01 ext Stations to ring upon Door Phone Activation 05 12 04 Door Relay Activat...

Страница 178: ...y will not be automatically answered until the message is complete and they are returned to the ringing queue As the DSS button is still indicating incoming ring the operator can manually press the DSS button of the trunk and pull the call back from the Voice message and answer this way ACD 1 can be configured to answer in 2 ways firstly when ALL the ring assigned stations are busy or DND after th...

Страница 179: ...usy extension no answer even a call cut off message if absolutely necessary Messages will repeat at the time intervals specified until the caller is answered if full supervision is available when the caller hangs up A trunk which is answered by DISA will indicate solid red on the trunk DSS key after being answered by DISA Until answered it will ring on ring assigned stations and can be answered by...

Страница 180: ...rst and most desirable option is to use DISA busy tone detect which will set the VMU to listen for busy tone received when the incoming caller hangs up and clear down the call Also available are the Polarity reversal for incoming calls or Clear Forward depending on the country These are features that are provide by the Central Office and will need to be enabled by them Related programming modes 05...

Страница 181: ...e detect to clear down calls as no input is required from the Exchange and no additional charges can be incurred If callers are to access an outside line after DISA answer then this must be enabled in Mode 05 11 05 Calls through the system using this feature will be controlled by mode 05 06 06 which is a timer to make certain that calls do clear down when 2 trunks are tied together When a timer is...

Страница 182: ... s The ACP is similar in appearance to a normal door phone with a numeric keypad 2 extra keys Call and PRG and a 4 character LED display The ACP has a built in relay a sensor output and a case alarm for security The ACP phone can be connected to any Digital port up to the maximum number of ports available minus One It is recommended that one Digital phone be provide for programming so that changes...

Страница 183: ...set frequency Frequency 1 8 Background Music Mode 05 11 07 Door phone Ring time The time that the Door Phone will ring assigned stations when the Door Phone button is pressed Mode 05 12 04 Door Relay unlock time The time that the door relay will remain closed after the Unlock function is activated Mode 17 Forced Account Codes Used as a code to allow users to unlock the door from the ACP Mode 46 st...

Страница 184: ...ng is a feature provided from the exchange where a single telephone line will have 2 separate numbers The line will ring for each number but with a different cadence for each number Fax machines are readily available that will detect the difference in cadence and if the number rung is allocated as a fax number then the fax will answer but if the other number cadence is detected the fax will not ri...

Страница 185: ...1562 Park Lane South Suite 400 Jupiter FL 33458 http www transtelcommunications com All data and specifications are subject to change without notice ...

Отзывы: