Settings
129
26.5
Pad cleaning
Cleaning time
The push button
B
activates or deactivates the pad cleaning before the print cycle.
The push button
C
activates or deactivates the pad cleaning after the print cycle.
Only one of the two cleaning times can be activated.
Cleaning interval
After the set number of print cycles, a pad cleaning is performed.
Tape feeding duration
After the pad cleaning, the feed for the cleaning tape is switched on for the set time period.
Pad cleaning stroke
The pad stroke position on the cleaning tape of the pad cleaning.
During pad cleaning the machine moves backwards out of its home position.
In manual mode, if the pad cleaning is extended, the printer can be moved backwards in
jog mode to locate the position.
See Chapter
25.3.1 "Jog mode" on page 122
.
For an optimum printing result, the pad should only deform on the pad cleaning unit to
such an extent that the surface used for printing is cleaned.
B
C
Содержание MSE 100.1-EU L
Страница 1: ...SealCup Express Edition 2 English 2019 02 20 Pad Printer Program version 1 30 30...
Страница 4: ...4 Important Information...
Страница 18: ...18 Safety instructions...
Страница 34: ...34 Transport and Installation...
Страница 42: ...42 Pad cleaning...
Страница 62: ...62 Pad Assembly Magnetic Holder...
Страница 68: ...68 Clich Assembly EU 15 3 2 Clamp clich Push the clamping block up and tighten the clamping screw C C...
Страница 80: ...80 Clich Assembly US...
Страница 126: ...126 Manual Mode...
Страница 150: ...150 Admin Settings...
Страница 160: ...160 Notifications and Errors...
Страница 174: ...174 Automation Interface...
Страница 176: ...176 Password...