where
U0
Disable transmit all IDs
U4
Any tag ID separation
V0
Valid ID code criteria of one acquisition
V1
Valid ID code criteria of two acquisitions
V2
Valid ID code criteria of three acquisitions
V3
Valid ID code criteria of four acquisitions
For example, if factory default settings are assigned, the reader message is
RF0S U0 V0
which means separation of one ID for uniqueness filtering and a valid ID code criteria of one acquisition.
532 Display Wiegand Mode Status
!532
displays the Wiegand mode status as either enabled or disabled.
Reader message:
TOF <0 to 1>
where
0
Wiegand mode disabled
1
Wiegand mode enabled
533 Display Wiegand Retransmit Interval
!
533
displays the Wiegand retransmit interval. This interval specifies the delay in seconds
before the reader retransmits Wiegand data for a tag still in the read zone. The factory
default is 1 second.
Reader message:
WTI <01 to FF>
where
01
to
FF
= seconds (1–255) in hexadecimal.
Note: The actual value of the Wiegand retransmit interval may vary depending on the operative tag
read mode and the type of tag in the read field.
For example, 10 = 16 seconds and FF = 255 seconds. The retransmit interval in ATA tag
read mode is about twice these values.
AI1422E Reader User Guide
TransCore Proprietary
6–40