9. Verify that the lock LED is illuminated and that the PC is acquiring the tag data.
Note: If the
!41
command was issued prior to this test, the PC will be
receiving a continuous stream of tag data. If the
!41
command was not
issued, the reader responds with only one response. The Lock LED remains
illuminated as long as there is a tag in the field, but only one response is
forthcoming unless the
!41
command has been issued.
10. Remove the tag from the antenna field. The PC should stop reading the tag data.
11. Disable the trigger by disconnecting the jumper.
12. Toggle the on/off switch located on the front panel of the reader system to
OFF.
Note: Repeat this test several times. Each time, the lock LED should be
illuminated and the PC should be reporting the tag data.