!31N
appends information. Append time and date are not available to the AI1422E Reader.
Reader message:
IDAP T<0> D<0> X<0 to 1>
where
T0
Time not appended
T1
Time appended (not valid for the AI1422E Reader)
D0
Date not appended
D1
Date appended (not valid for the AI1422E Reader)
X0
Auxiliary information not appended (factory default)
X1
Auxiliary information appended
One space is required between each value. For example, if factory-default settings are
assigned, the reader response is
IDAP T0 D0 X0
indicating time, date, and auxiliary information not appended.
525 Display Communications Protocol Status
!525
displays the status of command
!61N
Selected Communications Protocol, Selected
Mode of Flow Control, and command !
612NN ECP
Timeout
.
Reader response:
ECPS P<0 to 2> T<01 to FF> X<0 to 2> S0
where
P0
Basic protocol enabled (factory default)
P1
ECP enabled
Txx
ECP timeout where xx = 01 to FE (hexadecimal) Timeout
(ms) = 50 * xx. If xx = FF, timeout disabled
X0
Flow control disabled
X1
Software flow control enabled (factory default)
S0
start of message character is !
For example, if factory default settings are assigned, the reader message is:
ECPS P0 TFE X1 S0
which means basic protocol enabled, an ECP timeout of 254 (12,700 ms, 12.7 sec),
software flow control enabled, and start of message character is
!
.
AI1422E Reader User Guide
TransCore Proprietary
6–36