Chapter 3 Installation
General
Equipment should be installed and serviced only by skilled, qualified personnel in restricted access
locations.
Mechanical
The AI1422E has a standard 1U sized hole pattern. For installation, use No. 10 rack US screws and torque
to 25-30 in-lbs. For metric, use M6 screws and torque to 3-4 N-m. Refer to
for diagram and
dimensions.
Electrical Power
Assembling the Power Connector
This section describes the steps to assemble the power connector. Typically, the power source is located
in the same cabinet with the AI1422E.
The Power cable requires an 18 AWG stranded wire or larger, with a minimum insulation rating of 70C and
150V. Wire must meet EN 60950-1 or other applicable component standards.
WARNING:
Ensure that the ON/OFF switch is in the
OFF
position and the
PWR ON
indicator is
not illuminated before servicing the unit.
1. Unpack the unit from the shipping crate and locate the power connector on the front panel
(
.
1.25
18.35
Figure 7 AI1422 Dimensions
Figure 8 Power Connector
Chapter 3 Installation
TransCore Proprietary
3–9