6
Safety Precautions
The
symbol appears next to a point that is particularly important:
DANGER: Addresses a circumstance that, if encountered, will
lead to death or serious injury.
WARNING: Addresses a circumstance that, if encountered, might
lead to death or serious injury.
CAUTION: Addresses a circumstance that, if encountered, may
cause damage to equipment or minor injury.
DANGER: Never operate the unit with the discharge valve closed
as it could cause the compressor to explode, causing death or
serious injury.
DANGER: Never apply heat to a sealed refrigeration system or
container because it could explode, causing death or serious
injury.
DANGER: Fluorocarbon refrigerants, in the presence of an open
flame or electrical short, produce toxic gases that are severe
respiratory irritants capable of causing death.
DANGER: Be careful when working with a refrigerant or
refrigeration system in any enclosed or confined area with a
limited air supply (i.e., a trailer, container or the hold of a ship).
Refrigerant tends to displace air and can cause oxygen depletion
which may result in death by suffocation.
WARNING: Always wear eye protection such as goggles or safety
glasses. Refrigerant liquid, refrigeration oil, and battery acid can
permanently damage the eyes (see First Aid under Refrigeration
Oil).
WARNING: Keep your hands away from fans when the unit is
running. This should also be considered when opening and
closing the compressor service valves.
WARNING: Make sure gauge manifold hoses are in good
condition. Never let them come in contact with a belt, fan motor
pulley, or any hot surface.
WARNING: Make sure all mounting bolts are tight and are of
correct length for their particular application.
Содержание Thermo King ES300
Страница 12: ...11 Required Tools ...
Страница 18: ...17 Dimensions Condenser Module Mounting Holes ...
Страница 19: ...18 Dimensions HMI A 140 mm 5 50 in B 46 mm 1 80 in C 12 mm 50 in ...
Страница 20: ...19 BLANK PAGE ...
Страница 24: ...23 Installation 2 ES300 Evaporators Alternative Installation Method Preferred Installation Method ...
Страница 26: ...25 Installation Refrigeration Module Alternative Installation Method Preferred Installation Method ...
Страница 28: ...27 Installation Power Pack Module Alternative Installation Method Preferred Installation Method ...
Страница 30: ...29 Installation Condenser Module Preferred Installation Method Alternative Installation Method ...
Страница 38: ...37 Important Suction Line Routing and P Trap Formation NOT ACCEPTABLE From Unit ...
Страница 40: ...39 Installation Refrigeration Tubes to Compressor ...
Страница 46: ...45 System Leak Check and Evacuation ...
Страница 48: ...47 Installation Electrical Connections ...
Страница 50: ...49 Electrical Connections Evaporator s ...
Страница 52: ...51 Installation Standby Power Receptacle ...
Страница 54: ...53 Installation Drain Hoses REMOTE Evaporator HOST Evaporator Defrost Heater Wires ...
Страница 56: ...55 Installation HMI ...
Страница 62: ...61 System Charging AMOUNT OF REFRIGERANT PER MODEL Model 50 5 00 lbs ...