64
Installation Check List
Components are installed with recommended hardware and
tightened securely.
All mounting holes and access holes are sealed with
neutral/alcohol cure silicone sealant.
All covers, guards or screens are installed securely on unit.
Evaporator drain hoses are angled downward for proper
drainage.
Drain hose heaters (if applicable) are installed correctly.
The orifice screen is installed in the expansion valve at the
evaporator.
In-cab controller installed and is accessible and visible from
the driver’s position.
Refrigerant hoses are not taut - they are able to absorb
vibrations.
Refrigerant hoses are not rubbing against moving
components, sharp objects, or items that can reach high
temperatures.
Compressor was filled with the proper amount and type of oil.
All electrical connectors are properly locked in place.
Standby Power Receptacle mounted securely to vehicle.
All electrical harnesses and wiring is routed and secured
adaquately.
Correct size and amperages fuse was installed in the main
power harness to the battery.
Maxi Fuse holder was secured properly with bolt and nut to
vehicle.
All battery connections are clean and tight.
Vehicle compressor drive kit test was carried out.
Complete refrigeration system was checked for leaks.
Unit is charged with correct type and amount of refrigerant.
SPR and CPR adjustment procedures were carried out and
unit operates at its maximum capacity.
Unit operates correctly
.
P-Trap installed correctly
.
Compressor ground strap installed
.
Содержание Thermo King ES300
Страница 12: ...11 Required Tools ...
Страница 18: ...17 Dimensions Condenser Module Mounting Holes ...
Страница 19: ...18 Dimensions HMI A 140 mm 5 50 in B 46 mm 1 80 in C 12 mm 50 in ...
Страница 20: ...19 BLANK PAGE ...
Страница 24: ...23 Installation 2 ES300 Evaporators Alternative Installation Method Preferred Installation Method ...
Страница 26: ...25 Installation Refrigeration Module Alternative Installation Method Preferred Installation Method ...
Страница 28: ...27 Installation Power Pack Module Alternative Installation Method Preferred Installation Method ...
Страница 30: ...29 Installation Condenser Module Preferred Installation Method Alternative Installation Method ...
Страница 38: ...37 Important Suction Line Routing and P Trap Formation NOT ACCEPTABLE From Unit ...
Страница 40: ...39 Installation Refrigeration Tubes to Compressor ...
Страница 46: ...45 System Leak Check and Evacuation ...
Страница 48: ...47 Installation Electrical Connections ...
Страница 50: ...49 Electrical Connections Evaporator s ...
Страница 52: ...51 Installation Standby Power Receptacle ...
Страница 54: ...53 Installation Drain Hoses REMOTE Evaporator HOST Evaporator Defrost Heater Wires ...
Страница 56: ...55 Installation HMI ...
Страница 62: ...61 System Charging AMOUNT OF REFRIGERANT PER MODEL Model 50 5 00 lbs ...