58
Installation - Electrical Connections to Battery
In-Line Fuse Installation
IMPORTANT: The in-line fuse must be located in an accessible location
as close to the battery as possible while keeping it from directly touching
or laying on the battery.
1. Cut one in-line fuse wire to a maximum length of 12.00 in. (305 mm)
and strip 0.50 in. (12 mm) from the end.
2. Slide the heat shrink tubing onto the wire and position it away from the
connection.
3. Securely crimp and solder the correct size ring terminal onto the wire.
4. Position the heat shrink tubing over the body of the terminal and the
wire and then apply heat.
5. Cut the other end of the in-line fuse wire and the unit’s power (2) wire
to appropriate lengths and strip 0.50 in. (12 mm) from the ends of each
wire.
6. Slide the heat shrink tubing onto one wire and position it away from the
connection.
7. Using the supplied butt splice connector, securely crimp and solder the
two wires together.
8. Position the heat shrink tubing over the entire connection and then
apply heat.
9. Attach the ring terminal onto the positive (+) battery lug and tighten
securely.
10. Route and secure the in-line fuse to the vehicle or alongside the
positive battery cable with the supplied cable ties.
•
The in-line fuse should be positioned vertically to help promote
water drainage.
•
Fuses mounted horizontally must have the slit in the sleeving
pointing downwards.
Cable ties should be positioned within 5.00 in. (127 mm) on each side of
fuse as shown and no further than 10.00 in. (254 mm) apart.
Ground Wire
11. Securely crimp and solder the correct size ring terminal onto the CH
wire.
12. Position the heat shrink tubing over the body of the ring terminal and
the wire and then apply heat.
13. Attach the negative (CH) wire to negative (-) post of battery securely.
Содержание Thermo King ES300
Страница 12: ...11 Required Tools ...
Страница 18: ...17 Dimensions Condenser Module Mounting Holes ...
Страница 19: ...18 Dimensions HMI A 140 mm 5 50 in B 46 mm 1 80 in C 12 mm 50 in ...
Страница 20: ...19 BLANK PAGE ...
Страница 24: ...23 Installation 2 ES300 Evaporators Alternative Installation Method Preferred Installation Method ...
Страница 26: ...25 Installation Refrigeration Module Alternative Installation Method Preferred Installation Method ...
Страница 28: ...27 Installation Power Pack Module Alternative Installation Method Preferred Installation Method ...
Страница 30: ...29 Installation Condenser Module Preferred Installation Method Alternative Installation Method ...
Страница 38: ...37 Important Suction Line Routing and P Trap Formation NOT ACCEPTABLE From Unit ...
Страница 40: ...39 Installation Refrigeration Tubes to Compressor ...
Страница 46: ...45 System Leak Check and Evacuation ...
Страница 48: ...47 Installation Electrical Connections ...
Страница 50: ...49 Electrical Connections Evaporator s ...
Страница 52: ...51 Installation Standby Power Receptacle ...
Страница 54: ...53 Installation Drain Hoses REMOTE Evaporator HOST Evaporator Defrost Heater Wires ...
Страница 56: ...55 Installation HMI ...
Страница 62: ...61 System Charging AMOUNT OF REFRIGERANT PER MODEL Model 50 5 00 lbs ...