
62
CG-SVX039C-GB
Optional Free-Cooling
Table 15 – General Data for Partial Heat recovery CXAF 080-190 Standard Efficiency
CXAF
CXAF
CXAF
CXAF
CXAF
CXAF
CXAF
CXAF
CXAF
CXAF
CXAF
CXAF
CXAF
80
90
100
80
90
100
110
130
140
150
165
180
190
SSE
SSE
SSE
SE
SE
SE
SE
SE
SE
SE
SE
SE
SE
Partial Heat recovery (PHR) option
Heat-Exchanger
Type
Stainless steel Copper Brazed plate Heat exchanger
Digit 19=N or C
Heat-Exchanger
Model
B12MT/
D-60
B12MT/
D-80
B12MT/
D-80
B12MT/
D-60
B12MT/
D-80
B12MT/
D-80
B35TM4/
D-48
B35TM4/
D-48
B35TM4/
D-64
B35TM4/
D-64
B35TM4/
D-64
B35TM4/
D-64
B35TM4/
D-64
Water connection
size (Thread
connection)
(in)
-(mm)
1"1/2 -
48.3
2” -
60.3
2” -
60.3
1"1/2 -
48.3
2” -
60.3
2” -
60.3
2” -
60.3
2” -
60.3
2”1/2 -
76.1
2”1/2 -
76.1
2”1/2 -
76.1
2”1/2 -
76.1
2”1/2 -
76.1
Water content
volume
(l)
1.8
2.4
2.4
1.8
2.4
2.4
4.32
4.32
5.76
5.76
5.76
5.76
5.76
Digit 19=P
Heat-Exchanger
Model
B12MT/
D-48
B12MT/
D-48
B12MT/
D-48
B12MT/
D-48
B12MT/
D-48
B12MT/
D-48
B12MT/
D-48
B12MT/
D-60
B35TM4/
D-64
B35TM4/
D-64
B35TM4/
D-64
B35TM4/
D-64
B35TM4/
D-64
Water connection
size (Thread
connection)
(in) -
(mm)
1"1/2 -
48.3
1”1/2 -
48.3
1”1/2 -
48.3
1"1/2 -
48.3
1”1/2 -
48.3
1”1/2 -
48.3
1”1/2 -
48.3
2” - 60.3 2” - 60.3 2” - 60.3 2” - 60.3
2”1/2 -
76.1
2”1/2 -
76.1
Water content
volume
(l)
1.44
1.44
1.44
1.44
1.44
1.44
1.44
1.8
4.32
4.32
4.32
4.32
4.32
Antifreeze Heater
Max Power Input
(Standard Digit
19=N or C /
Process Digit 19=P)
(W) 60 / 60 60 / 60
60 / 60
60 / 60
60 / 60
60 / 60 120 / 60 120 / 60
120 /
120
120 /
120
120 /
120
120 /
120
120 /
120
Antifreeze Heater
Max Amps
(Standard Digit
19=N or C /
Process Digit 19=P)
(A)
0.15 /
0.15
0.15 /
0.15
0.15 /
0.15
0.15 /
0.15
0.15 /
0.15
0.15 /
0.15
0.3 /
0.15
0.3 /
0.15
0.3 /
0.3
0.3 /
0.3
0.3 /
0.3
0.3 /
0.3
0.3 /
0.3
Table 16 – General Data for Partial Heat recovery CXAF 080-190 High Efficiency
CXAF
CXAF
CXAF
CXAF
CXAF
CXAF
CXAF
CXAF
CXAF
CXAF
CXAF
CXAF
CXAF
80
90
100
80
90
100
110
130
140
150
165
180
190
SHE
SHE
SHE
HE
HE
HE
HE
HE
HE
HE
HE
HE
HE
Partial Heat recovery (PHR) option
Heat-Exchanger Type
Stainless steel Copper Brazed plate Heat exchanger
Digit 19=N or C
Heat-Exchanger Model
B12MT/
D-60
B12MT/
D-80
B12MT/
D-80
B12MT
/D-60
B12MT
/D-80
B12MT
/D-80
B35TM4
/D-48
B35TM4
/D-48
B35TM4
/D-64
B35TM4
/D-64
B35TM4
/D-64
B35TM4
/D-64
B35TM4
/D-64
Water connection size
(Thread connection)
(in)
-(mm)
1"1/2 -
48.3
2” -
60.3
2” -
60.3
1"1/2 -
48.3
2" -
60.3
2" -
60.3
2" -
60.3
2" -
60.3
2"1/2 -
76.1
2"1/2
-76.1
2"1/2
-76.1
2"1/2
-76.1
2"1/2
-76.1
Water content volume
(l)
1.8
2.4
2.4
1.8
2.4
2.4
4.32
4.32
5.76
5.76
5.76
5.76
5.76
Digit 19=P
Heat-Exchanger Model
B12MT/
D-48
B12MT/
D-48
B12MT/
D-48
B12MT/
D-48
B12MT/
D-48
B12MT/
D-48
B12MT/
D-48
B12MT/
D-60
B35TM4/
D-48
B35TM4/
D-48
B35TM4/
D-48
B35TM4/
D-64
B35TM4/
D-64
Water connection size
(Thread connection)
(in)
-(mm)
1"1/2 -
48.3
1”1/2 -
48.3
1”1/2 -
48.3
1"1/2 -
48.3
1”1/2 -
48.3
1”1/2 -
48.3
1”1/2 -
48.3
2” -
60.3
2” - 60.3 2” - 60.3 2” - 60.3
2”1/2 -
76.1
2”1/2 -
76.1
Water content volume
(l)
1.44
1.44
1.44
1.44
1.44
1.44
1.44
1.8
4.32
4.32
4.32
4.32
4.32
Antifreeze Heater Max
Power Input (Standard
Digit 19=N or C /
Process Digit 19=P)
(W)
60 / 60
60 / 60
60 / 60 60 / 60 60 / 60 60 / 60
120 /
60
120 /
60
120 /
120
120 /
120
120 /
120
120 /
120
120 /
120
Antifreeze Heater Max
Amps (Standard Digit
19=N or C / Process
Digit 19=P)
(A)
0.15 /
0.15
0.15 /
0.15
0.15 /
0.15
0.15 /
0.15
0.15 /
0.15
0.15 /
0.15
0.3 /
0.15
0.3 /
0.15
0.3 / 0.3 0.3 / 0.3 0.3 / 0.3 0.3 / 0.3 0.3 / 0.3
Содержание Sintesis Advantage CGAF 100 SE
Страница 34: ...34 CG SVX039C GB Top view Typical CGAF CXAF Components location ...
Страница 35: ...CG SVX039C GB 35 Typical CGAF CXAF Components location ...
Страница 36: ...36 CG SVX039C GB Typical CGAF CXAF Components location ...
Страница 85: ......
Страница 86: ......
Страница 87: ......