RT-SVX39B-EN
5
Model Number Description
Digit 1 - Unit Type
W Packaged Heat Pump
Digit 2 - Efficiency
S
Standard Efficiency
Digit 3 - Airflow
C
Convertible
Digit 4,5,6 - Nominal Gross
Cooling Capacity (MBh)
036
3 Ton
048
4 Ton
060
5 Ton
072
6 Ton
090
7½ Ton, Single Compressor
120
10 Ton
Digit 7 - Major Design Sequence
E
R-410A Refrigerant
Digit 8 - Voltage Selection
1
208-230/60/1
3
208-230/60/3
4
460/60/3
W 575/60/3
Digit 9 - Unit Controls
R
ReliaTel™ Microprocessor
Digit 10 - Heating Capacity
Digit 11 - Minor Design
Sequence
A
First Sequence
Digit 12,13 - Service Sequence
** Factory Assigned
Digit 14 - Fresh Air Selection
0
No Fresh Air
A
Manual Outside Air Damper 0-50%
B
Motorized Outside Air Damper
0-50%
C
Economizer, Dry Bulb 0-100%
without Barometric Relief
D
Economizer, Dry Bulb 0-100%
with Barometric Relief
E
Economizer, Reference Enthalpy
0-100% without Barometric Relief
F
Economizer, Reference Enthalpy
0-100% with Barometric Relief
G
Economizer, Comparative
Enthalpy 0-100% without
Barometric Relief
H
Economizer, Comparative
Enthalpy 0-100% with Barometric
Relief
Digit 15 - Supply Fan/Drive Type/
Motor
0
Standard Drive
1
Oversized Motor
2
Optional Belt Drive Motor
6
Single Zone Variable Air
Volume (SZVAV)
7
Multi-Speed Indoor Fan
Digit 16 - Hinged Service
Access/Filters
0
Standard Panels/Standard Filters
A
Hinged Access Panels/Standard
Filters
B
Standard Panels/2” MERV 8 Filters
C
Hinged Access Panels/2” MERV 8
Filters
D
Standard Panels/2” MERV 13 Filters
E
Hinged Access Panels/2” MERV 13
Filters
Digit 17 - Condenser Coil
Protection
0
Standard Coil
1
Standard Coil with Hail Guard
2
Black Epoxy Pre-Coated Condenser
Coil
3
Black Epoxy Pre-Coated
Condenser Coil with Hail Guard
Digit 18 - Through the Base
Provisions
0
No Through the Base Provisions
A
Through the Base Electric
Digit 19 - Disconnect/Circuit
Breaker (three-phase only)
0
No Disconnect/No Circuit Breaker
1
Unit Mounted Non-Fused
Disconnect
2
Unit Mounted Circuit Breaker
Digit 20 - Convenience Outlet
0
No Convenience Outlet
A
Unpowered Convenience Outlet
B
Powered Convenience Outlet
(three-phase only)
Digit 21 - Communications
Options
0
No Communications Interface
1
Trane Communications Interface
2
LonTalk® Communications Interface
6
BACnet™ Communications Interface
Digit 22 - Refrigeration System
Option
0
Standard Refrigeration System
Digit 23 - Refrigeration Controls
0
No Refrigeration Control
1
Frostat
2
Crankcase Heater
3
Frostat and Crankcase Heater
Digit 24 - Smoke Detector
0
No Smoke Detector
A
Return Air Smoke Detector
B
Supply Air Smoke Detector
C
Supply and Return Air Smoke
Detectors
D
Plenum Smoke Detector
Digit 25 - System Monitoring
Controls
0
No Monitoring Control
1
Clogged Filter Switch
2
Fan Failure Switch
3
Discharge Air Sensing Tube
4
Clogged Filter Switch and Fan
Fail Switch
5
Clogged Filter Switch and Discharge
Air Sensing Tube
6
Fan Fail Switch and Discharge Air
Sensing Tube
7
Clogged Filter and Fan Fail Switches
and Discharge Air Sensing Tube
A
Condensate Drain Pan Overflow
Switch
B
Clogged Filter Switch and
Condensate Drain Pan Overflow
Switch
C
Fan Failure Switch and Condensate
Drain Pan Overflow Switch
D
Discharge Air Sensing and
Condensate Drain Pan Overflow
Switch
E
Clogged Filter Switch, Fan Failure
Switch and Condensate Drain Pan
Overflow Switch
F
Clogged Filter Switch, Discharge
Air Sensing Tube and Condensate
Drain Pan Overflow Switch
G
Fan Failure Switch, Discharge Air
Sensing Tube and Condensate
Drain Pan Overflow Switch
H
Clogged Filter Switch, Fan Failure
Switch, Discharge Air Sensing
and Condensate Drain Pan Overflow
Switch
Digit 26 - System Monitoring
Controls
0
No Monitoring Controls
A
Demand Control Ventilation (CO
2
Digit 27 - Unit Hardware
Enhancements
0
No Enhancements
1
Stainless Steel Drain Pan
W
S
C
1
2
0
E
4
R
0
A
*
*
1
2
3
4
5
6
7
8
9
10
11
12
13
0=No Electric Heat
F=14 kW (1 phase)
A=5 kW (1 phase)
G=18 kW (1&3 phase)
B=6 kW (3 phase)
J=23 kW (3 phase)
C=9 kW (3 phase)
K= 27 kW (3 phase)
D=10 kW (1 phase)
N = 36 kW (3 phase)
E=12 kW (3 phase)
P = 54 kW (3 phase)