RT-SVX072A-EN
90 to 130 Tons, Air Cooled
Digit 1 — Unit Type
S
= Self-Contained (Packaged Rooftop)
Digit 2 — Unit Function
E
= DX Cooling, Electric Heat
F
= DX Cooling, Natural Gas Heat
L
= DX Cooling, Hot Water Heat
S
= DX Cooling, Steam Heat
X
= DX Cooling, No Heat, Extended Casing
Digit 3 — System Type
H
= Single Zone
Digit 4 — Development Sequence
L
= R-410A Development Sequence
Digit 5, 6, 7 — Nominal Capacity
*90
= 90 Ton Air Cooled
*11
= 105 Ton Air Cooled
*12
= 115 Ton Air Cooled
*13
= 130 Ton Air Cooled
Digit 8 — Power Supply
4
= 460/60/3 XL
5
= 575/60/3 XL
Digit 9 — Heating Capacity
Note:
When Digit 2 is “F” (Gas Heat), the
following values apply in Digit 9:
H
= High Heat – 2-stage
O
= No Heat
P
= High Heat — Modulation
T
= High Heat—Ultra Modulation
Note:
When the second digit calls for “E”
(electric heat), the following values
apply in Digit 9:
W
= 190 kW
Note:
When the second digit calls for “L” (hot
water) or “S” (steam) heat, one of the
following valve size values must be in
Digit 9:
High Heat Coil:
3 = 1", 4 = 1.25", 5 = 1.5",
6 = 2", 7 = 2.5”
Low Heat Coil:
C = 1", D = 1.25", E = 1.5", F
= 2", G = 2.5”
Digit 10 — Design Sequence
*
= Current
Note:
Sequence may be any letter A through
Z, or any digit 1 through 9.
Digit 11 — Relief Option
0
= None
7
= 100% Relief 15 HP with Statitrac
8
= 100% Relief 20 HP with Statitrac
9
= 100% Relief 25 HP with Statitrac
H
= 100% Relief 30 HP with Statitrac
J
= 100% Relief 40 HP with Statitrac
Digit 12 — Relief Fan
(Relief Fan)
0
= None
5
= 500 RPM
6
= 600 RPM
7
= 700 RPM
8
= 800 RPM
Digit 13 — Filter (Pre DX/Final)
A
= Throwaway
C
= High Efficiency Throwaway
D
= Bag with Prefilter
E
= Cartridge with Prefilter
F
= Throwaway Filter Rack (filter not
included)
G
= Bag Filter Rack (Filter Not Included)
H
= StandardThrowaway Filter/Cartridge
Final Filters
J
= High Efficiency Throwaway Filter/
Cartridge Final Filters
K
= Bag Filters with 2"Throwaway Prefilters/
Cartridge Final Filters
L
= Cartridge Filters with 2"Throwaway
Prefilters /Cartridge Final Filters
M
= StandardThrowaway Filter/Cartridge
Final Filters with 2–inch Throwaway Prefilters
N
= High EfficiencyThrowaway Filters/
Cartridge Final Filters with 2–inch Throwaway
Prefilters
P
= Bag Filters with Prefilters Cartridge Final
Filters with 2–inch Throwaway Prefilters
Q
= Cartridge Filters with Prefilters/Cartridge
Final Filters with 2–inch Throwaway Prefilters
Digit 14 — Supply Air Fan HP
C
= 30 HP (2x15 HP)
D
= 40 HP (2x20 HP)
E
= 50 HP (2x25 HP)
F
= 60 HP (2x30 HP)
G
= 80 HP (2x40 HP)
Digit 15 — Supply Air Fan Drive
A
= 1000 RPM
B
= 1100 RPM
C
= 1200 RPM
D
= 1300 RPM
E
= 1400 RPM
F
= 1500 RPM
G
= 1600 RPM
Digit 16 — Outside Air
D
= 0-100% Economizer (Std.)
E
= 0-100% Economizer with Traq with DCV
F
= 0-100% Economizer with DCV
Note:
Must install CO
2
sensor(s) for DCV to
function properly.
Digit 17 — System Control
6
= VAV Discharge Temperature Control with
VFD without Bypass
7
= VAV Discharge Temperature Control with
VFD and Bypass
8
= VAV Discharge Temperature Control
Supply and ReliefFan with VFD without
Bypass
9
= VAV Discharge Temperature Control
Supply and Relief Fan with VFD and Bypass
A
= VAV – Single Zone VAV – with VFD
without Bypass
B
= VAV – Single Zone VAV – with VFD with
Bypass
C
= VAV – Single Zone VAV – Supply and
Relief/Return Fan with VFD without Bypass
D
= VAV – Single Zone VAV – Supply and
Relief/Return Fan with VFD with Bypass
Digit 18 — Zone Sensor
0
= None
A
= Dual Setpoint Manual or Auto
Changeover (BAYSENS108*)
C
= Room Sensor with Override and Cancel
Buttons (BAYSENS073*)
D
= Room Sensor with Temperature
Adjustment and Override and Cancel Buttons
(BAYSENS074*)
L
= Programmable Zone Sensor with System
Function Modes for VAV (BAYSENS800*)
Note:
*Asterisk indicates current model
number digit A, B, C, etc. These
sensors can be ordered to ship with
the unit.