background image

CVHE-SVN04M-EN

21

is to remove the sensor and carefully coil the wire after
labeling the device and its location to aid in
reinstallation. All sensors connect to the buss wiring
with a universal plug. This allows easy disconnection
and reconnection of the sensors.

Purge Unit Removal

W

WA

AR

RN

NIIN

NG

G

R

Re

effrriig

ge

erra

an

ntt M

Ma

ay

y B

Be

e U

Un

nd

de

err P

Po

ossiittiiv

ve

e

P

Prre

essssu

urre

e!!

F

Fa

aiillu

urre

e tto

o ffo

ollllo

ow

w iin

nssttrru

uccttiio

on

nss b

be

ello

ow

w cco

ou

ulld

d rre

essu

ulltt iin

n

a

an

n e

ex

xp

pllo

ossiio

on

n w

wh

hiicch

h cco

ou

ulld

d rre

essu

ulltt iin

n d

de

ea

atth

h o

orr

sse

erriio

ou

uss iin

njju

urry

y o

orr e

eq

qu

uiip

pm

me

en

ntt d

da

am

ma

ag

ge

e..

S

Sy

ysstte

em

m cco

on

ntta

aiin

nss rre

effrriig

ge

erra

an

ntt a

an

nd

d m

ma

ay

y b

be

e u

un

nd

de

err

p

po

ossiittiiv

ve

e p

prre

essssu

urre

e;; ssy

ysstte

em

m m

ma

ay

y a

allsso

o cco

on

ntta

aiin

n o

oiill..

R

Re

ecco

ov

ve

err rre

effrriig

ge

erra

an

ntt tto

o rre

elliie

ev

ve

e p

prre

essssu

urre

e b

be

effo

orre

e

o

op

pe

en

niin

ng

g tth

he

e ssy

ysstte

em

m.. S

Se

ee

e u

un

niitt n

na

am

me

ep

plla

atte

e ffo

orr

rre

effrriig

ge

erra

an

ntt tty

yp

pe

e.. D

Do

o n

no

ott u

usse

e n

no

on

n--a

ap

pp

prro

ov

ve

ed

d

rre

effrriig

ge

erra

an

nttss,, rre

effrriig

ge

erra

an

ntt ssu

ub

bssttiittu

utte

ess,, o

orr n

no

on

n--

a

ap

pp

prro

ov

ve

ed

d rre

effrriig

ge

erra

an

ntt a

ad

dd

diittiiv

ve

ess..

W

WA

AR

RN

NIIN

NG

G

H

Ha

azza

arrd

do

ou

uss V

Vo

olltta

ag

ge

e w

w//C

Ca

ap

pa

acciitto

orrss!!

F

Fa

aiillu

urre

e tto

o d

diisscco

on

nn

ne

ecctt p

po

ow

we

err a

an

nd

d d

diisscch

ha

arrg

ge

e

cca

ap

pa

acciitto

orrss b

be

effo

orre

e sse

errv

viicciin

ng

g cco

ou

ulld

d rre

essu

ulltt iin

n d

de

ea

atth

h o

orr

sse

erriio

ou

uss iin

njju

urry

y..

D

Diisscco

on

nn

ne

ecctt a

allll e

elle

eccttrriicc p

po

ow

we

err,, iin

nccllu

ud

diin

ng

g rre

em

mo

otte

e

d

diisscco

on

nn

ne

eccttss a

an

nd

d d

diisscch

ha

arrg

ge

e a

allll m

mo

otto

orr sstta

arrtt//rru

un

n

cca

ap

pa

acciitto

orrss b

be

effo

orre

e sse

errv

viicciin

ng

g.. F

Fo

ollllo

ow

w p

prro

op

pe

err

llo

occkko

ou

utt//tta

ag

go

ou

utt p

prro

occe

ed

du

urre

ess tto

o e

en

nssu

urre

e tth

he

e p

po

ow

we

err

cca

an

nn

no

ott b

be

e iin

na

ad

dv

ve

errtte

en

nttlly

y e

en

ne

errg

giizze

ed

d.. F

Fo

orr v

va

arriia

ab

blle

e

ffrre

eq

qu

ue

en

nccy

y d

drriiv

ve

ess o

orr o

otth

he

err e

en

ne

errg

gy

y sstto

orriin

ng

g

cco

om

mp

po

on

ne

en

nttss p

prro

ov

viid

de

ed

d b

by

y T

Trra

an

ne

e o

orr o

otth

he

errss,, rre

effe

err tto

o

tth

he

e a

ap

pp

prro

op

prriia

atte

e m

ma

an

nu

uffa

accttu

urre

err’’ss lliitte

erra

attu

urre

e ffo

orr

a

allllo

ow

wa

ab

blle

e w

wa

aiittiin

ng

g p

pe

erriio

od

dss ffo

orr d

diisscch

ha

arrg

ge

e o

off

cca

ap

pa

acciitto

orrss.. V

Ve

erriiffy

y w

wiitth

h a

a C

CA

AT

T IIIIII o

orr IIV

V v

vo

ollttm

me

ette

err

rra

atte

ed

d p

pe

err N

NF

FP

PA

A 7

70

0E

E tth

ha

att a

allll cca

ap

pa

acciitto

orrss h

ha

av

ve

e

d

diisscch

ha

arrg

ge

ed

d..

F

Fo

orr a

ad

dd

diittiio

on

na

all iin

nffo

orrm

ma

attiio

on

n rre

eg

ga

arrd

diin

ng

g tth

he

e ssa

affe

e

d

diisscch

ha

arrg

ge

e o

off cca

ap

pa

acciitto

orrss,, sse

ee

e P

PR

RO

OD

D--S

SV

VB

B0

06

6*

*--E

EN

N..

To remove the purge assembly from the top of the
condenser:

1. Isolate the purge unit from the condenser shell by

closing the vapor and liquid line valves.

2. Disconnect and mark all piping and wiring attached

to the purge unit. Sand all paint off at points and
use a tubing cutter where cuts are to be made. See

Figure 5, p. 21

and

Figure 6, p. 21

.

3. Remove the fasteners connecting the purge unit

base to its mounting bracket.

4. Two people will be needed to lift purge unit clear of

the chiller. Refer to

Table 10, p. 18

for purge unit

weight. Store the purge unit in a clean dry area.

Reassemble the purge unit in reverse order when the
process is complete.

Figure 5. Example purge unit

Figure 6. Purge unit detail

N

No

otte

e:: Purge unit may appear slightly different than

example shown here.

D

Diissa

asssse

em

mb

blly

y

Содержание CenTraVac CDHF

Страница 1: ...knowledge and training Improperly installed adjusted or altered equipment by an unqualified person could result in death or serious injury When working on the equipment observe all precautions in the...

Страница 2: ...th he e j jo ob b b be ei in ng g u un nd de er rt ta ak ke en n c co ou ul ld d r re es su ul lt t i in n d de ea at th h o or r s se er ri io ou us s i in nj ju ur ry y T Te ec ch hn ni ic ci ia an...

Страница 3: ...11 Factory Warranty Information Compliance with the following is required to preserve the factory warranty A Al ll l U Un ni it t I In ns st ta al ll la at ti io on ns s Startup MUST be performed by...

Страница 4: ...ta an nt t These procedures do NOT apply to units that have been installed and electrical supply wiring has been completed Contractor Responsibilities W WA AR RN NI IN NG G H He ea av vy y O Ob bj je...

Страница 5: ...pass INDP Optional industrial control package SMP Optional supplemental motor protection INDP units only UAFD Unit mounted Adaptive Frequency drive UATR Unit mounted medium voltage auto transformer UP...

Страница 6: ...42 0 78 3 51 3 59 1 93 8 45 5 62 2 63 5 44 3 620 870 080 870 93 5 75 0 101 3 42 0 81 2 59 7 73 2 93 8 45 5 63 9 63 5 44 3 080 142 870 101 3 79 4 107 5 a 81 3 59 7 73 2 102 0 45 5 67 9 63 59 46 0 142...

Страница 7: ...102 0 45 5 64 3 63 59 46 0 142 920 98 1 84 0 111 0 a 93 2 54 3 68 0 105 5 46 9 69 8 62 5 46 0 142 210 920 106 0 89 7 109 7 a 93 3 54 6 68 7 105 4 46 9 76 2 62 5 52 4 210 920 106 5 96 0 116 0 a 93 2 54...

Страница 8: ...21 1 36 8 126 9 129 0 N A N A 72 7 210 1300 93 8 76 4 86 9 N A 21 1 36 8 124 7 135 2 87 2 87 2 82 4 250 1300 97 9 80 4 90 9 N A 18 6 36 8 137 2 139 4 N A N A 82 7 1470 1720 142 210 1720 86 5 72 8 83 3...

Страница 9: ...9 77 5 N A 146 0 91 0 4 6 142 210 1300 a a a a 147 9 83 6 3 5 154 9 90 6 5 6 210 1300 a a a a N A N A N A 152 4 95 9 3 9 250 1300 140 7 b 80 2 a N A N A N A 160 0 99 5 3 1 1470 1720 142 210 1720 a a a...

Страница 10: ...SEE NOTE 4 N No ot te es s 1 All dimensions are in inches 0 5 inch See Table 1 p 6 through Table 5 p 13 for dimension tables 2 UAFD brackets and supports shown are bolt on and removable Most brackets...

Страница 11: ...ble See Table 5 p 13 for application dimensions 3 Applies only to CVHE 190 320 NTON on 032 shells with free cooling option 4 Add 1 5 inch for distance to Tracer Adaptiview display mounting arm in stow...

Страница 12: ...N A 5000 a N A a N A 5800 a N A 123 4 N A 870 1300 440E a a a a 5000 a a a a 5800 a a 123 4 123 7 Table 4 Motor terminal boxes for CVHE CVHF and CVHG CenTraVac chillers continued Shell Size Comp Size...

Страница 13: ...5 69 3 75 9 050 080 480 400 92 4 N A 51 59 N A 440E 94 9 101 6 54 09 60 85 500 400 92 4 N A 51 59 N A 440E 94 9 101 6 54 09 60 85 565 440E 96 2 103 0 54 09 60 85 5000 97 7 104 3 55 59 62 19 080 142 7...

Страница 14: ...1 9 52 4 93 8 2250 2 Comp 2500 120 9 0 5 121 6 73 2 94 2 59 7 120 6 116 4 54 5 79 7 76 9 56 8 94 6 CDHF 3000 2 Comp 250M 120 9 0 5 121 6 76 3 92 3 63 1 120 6 116 4 54 5 84 3 76 9 56 8 96 8 3500 2 Comp...

Страница 15: ...7 1 3 092 1100 440E 6 8 11 8 13 1 3 1 5000 6 8 11 8 11 6 1 6 5800 6 8 11 8 9 8 0 2 2500 130 440E 3 6 0 5 21 1 11 1 5000 3 6 2 0 19 6 9 6 5800 3 6 3 8 17 8 7 8 092 110 440E 3 6 5 5 21 1 11 1 5000 3 6 7...

Страница 16: ...PORTS CAN BE UNBOLTED FROM BRACKETS AFD CONTROL PANEL Y2 UATR UPIR UXL STARTERS Y3 MOTOR TERMINAL BOX NOT SHOWN Y1 USTR USID STARTERS CONTROL PANEL K X Z W 1 0 90D 1210A AFD AFD DISCONNECT SWITCH TO E...

Страница 17: ...TS ARE WELDED TO EVAPORATOR ON 900 1210A AFD SUPPORTS CAN BE UNBOLTED FROM BRACKETS LARGEST MOTOR MOTOR S SPACE REMOVAL T MAX OD LARGEST MOTOR CHILLER DIMENSIONS INCHES F C CDHF UNIT SHOWN COOLING ONL...

Страница 18: ...d 10 a Heaviest motor used does not include the weight of the suction elbow b For Duplex chillers weights shown are for individual components multiply by two for total component weights for Duplex chi...

Страница 19: ...g 5190 f 250M 2500 28679 13008 10954 f 4969 f 29817 13524 11442 f 5190 f 250X 2500 31902 14470 10954 f 4969 f 33486 15188 11442 f 5190 f Note All weights are nominal and 10 a Bundle weights are for th...

Страница 20: ...units ship with a 5 psig 34 5 kPag dry nitrogen holding charge at nominal 72 F 22 C I Im mp po or rt ta an nt t New units that have been factory run tested contain residual refrigerant vent discharge...

Страница 21: ...t te e d di is sc co on nn ne ec ct ts s a an nd d d di is sc ch ha ar rg ge e a al ll l m mo ot to or r s st ta ar rt t r ru un n c ca ap pa ac ci it to or rs s b be ef fo or re e s se er rv vi ic ci...

Страница 22: ...t ta al ll le ed d a an nd d i it t i is s n ne ec ce es ss sa ar ry y t to o i in ns st ta al ll l d do ow we el li in ng g c co on nt ta ac ct t t th he e l lo oc ca al l T Tr ra an ne e S Se er rv...

Страница 23: ...at te e f fo or r r re ef fr ri ig ge er ra an nt t t ty yp pe e D Do o n no ot t u us se e n no on n a ap pp pr ro ov ve ed d r re ef fr ri ig ge er ra an nt ts s r re ef fr ri ig ge er ra an nt t s...

Страница 24: ...l ly y f fo or r r re em mo ov vi in ng g w wa at te er rb bo ox x f fr ro om m c ch hi il ll le er r 6 Remove the suction elbow There are two styles of suction elbows a 90 elbow and a three piece elb...

Страница 25: ...i ic ch h c co ou ul ld d r re es su ul lt t i in n d de ea at th h o or r s se er ri io ou us s i in nj ju ur ry y o or r e eq qu ui ip pm me en nt t d da am ma ag ge e S Sy ys st te em m c co on nt...

Страница 26: ...essor 11 Use the reverse order to reassemble the economizer on the chiller Be sure to install new gaskets at the appropriate joints 12 Torque all bolts to specifications Consult with your Trane servic...

Страница 27: ...er r N NF FP PA A 7 70 0E E t th ha at t a al ll l c ca ap pa ac ci it to or rs s h ha av ve e d di is sc ch ha ar rg ge ed d F Fo or r a ad dd di it ti io on na al l i in nf fo or rm ma at ti io on...

Страница 28: ...ie es s o on ne e a at t a a t ti im me e 5 Loosen the bolts which hold the starter to the flange on the motor Steady the starter panel as the retaining bolts are removed because the panel will tip fo...

Страница 29: ...ge er ra an nt t s su ub bs st ti it tu ut te es s o or r n no on n a ap pp pr ro ov ve ed d r re ef fr ri ig ge er ra an nt t a ad dd di it ti iv ve es s W WA AR RN NI IN NG G H He ea av vy y O Ob b...

Страница 30: ...sed for removing the suction elbow Do not lift the piping simply support it to avoid slipping as the bolts are removed from the connecting flanges Typical rigging for lifting the suction elbow can be...

Страница 31: ...ot and discharge flange connections Before tightening any of these bolts reinstall the dowel pins in the compressor foot and discharge flange 4 Tighten the compressor foot and discharge flange bolts S...

Страница 32: ...ba ac ck k t to o a at tm mo os sp ph he er ri ic c p pr re es ss su ur re e b be ef fo or re e o op pe en ni in ng g s sy ys st te em m f fo or r r re ep pa ai ir rs s M Mi ix xt tu ur re es s o of f...

Страница 33: ...CVHE CVHF CVHG Water Cooled CenTraVac Chillers with Tracer AdaptiView Control and CDHF SVX01 EN Installation Operation and Maintenance CDHF and CDHG Water Cooled CenTraVac Chillers with Tracer Adapti...

Страница 34: ...34 CVHE SVN04M EN N No ot te es s...

Страница 35: ...CVHE SVN04M EN 35 N No ot te es s...

Страница 36: ...protect food and perishables and increase industrial productivity and efficiency We are a global business committed to a world of sustainable progress and enduring results ingersollrand com Ingersoll...

Отзывы: