8
AC-SVX001A-EN
Model Number Descriptions
Unit Model Number
Digit 1, 2, 3, 4 — Unit Model
ACRA
= Air-Cooled Screw Chiller
Digit 5, 6, 7 — Nominal Tonnage
150
= 150 Tons
165
= 165 Tons
180
= 180 Tons
200
= 200 Tons
225
= 225 Tons
250
= 250 Tons
275
= 275 Tons
300
= 300 Tons
Digit 8 — Unit Voltage
A
= 200/60/3
B
= 230/50/3
C
= 380/50/3
D
= 380/60/3
E
= 400/50/3
F
= 460/60/3
G
= 575/60/3
H
= 400/60/3
Digit 9 — Manufacturing Location
U
= Trane Commercial Systems, Pueblo, CO
USA
Digits 10, 11 — Design Sequence
**
= Factory assigned
Digit 12 — Unit Sound Package
1
= InvisiSound
™
Standard Unit
2
= InvisiSound
™
Superior (Line Wraps,
Reduced Fan Speed)
3
= InvisiSound
™
Ultimate (Compressor
Sound Attenuation, Line Wraps, Reduced Fan
Speed)
Digit 13 — Agency Listing
0
= No Agency Listing
A
= UL/cUL Listing
Digit 14 — Pressure Vessel Code
A
= ASME Pressure Vessel Code
C
= CRN or Canadian Equivalent Pressure
Vessel Code
D
= Australia Pressure Vessel Code
Digit 15 — Factory Charge
1
= Refrigerant Charge R-134a
2
= Nitrogen Charge
Digit 16 — Evaporator Application
F
= Standard Cooling (40 to 65°F/5.5 to 18°
C)
G
= Low Temp Process Cooling (below 40°F/
5.5°C)
C
= Ice Making (20 to 6°F/7 to 18°C) with
Hardwired Interface
Digit 17 — Evaporator Configuration
N
= 2-pass Evaporator
P
= 3-pass Evaporator
Digit 18 — Evaporator Fluid Type
1
= Water
2
= Calcium Chloride
3
= Ethylene Glycol
4
= Propylene Glycol
5
= Methanol
Digit 19 — Water Connection
X
= Grooved Pipe
F
= Grooved Pipe + Flange
Digit 20 — Flow Switch
1
= Factory Installed - Other Fluid (15 cm/s)
2
= Factory Installed - Water 2 (35 cm/s)
3
= Factory Installed - Water 3 (45 cm/s)
Digit 21 — Insulation
A
= Factory Insulation — All Cold Parts 0.75”
B
= Evaporator-only Insulation for High
Humidity/Low Evap Temp 1.25”
Digit 22 — Unit Application
1
= Standard Ambient (32 to 105°F/0 to
40.6°C)
2
= Low Ambient (0 to 105°F/-17.7 to 40.6°
C)
3
= Extreme Low Ambient (–20 to 105°F/
-28.9 to 40.6°C)
4
= High Ambient (32 to 125°F/0 to 52°C)
5
= Wide Ambient (0 to 125°F/-17.7 to 52°C)
Digit 23 — Condenser Fin Options
A
= Aluminum Fins with Slits
D
= CompleteCoat
™
Epoxy Coated Fins
Digit 24, 25 — Not Used
00
= Reserved for future use
Digit 26 — Power Line Connection
Type
A
= Terminal Block
C
= Circuit Breaker
D
= Circuit Breaker with High Fault Rated
Control Panel
Digit 27 — Short Circuit Current
Rating
A
= Default A Short Circuit Rating
B
= High A Short Circuit Rating
Digit 28 — Transformer
0
= No Transformer
1
= Factory Installed Transformer
Digit 29 — Line Voltage Harmonic
Mitigation
X
= DC Reactors (~30% TDD)
1
= Filter circuit (IEEE519 Compliant)
Digit 30 — Electrical Accessories
0
= No Convenience Outlet
C
= 15A 115V Convenience Outlet (Type B)
Digit 31 — Remote Communication
Option
0
= None
1
= LonTalk
®
Interface (LCI-C)
2
= BACnet
®
MS/TP Interface
3
= Modbus
™
Interface
Digit 32 — Hard Wire Communication
X
= None
A
= Hard Wired Bundle - All
B
= Remote Leaving Water Temp Setpoint
C
= Remote Leaving Temp and Demand Limit
Setpoints
D
= Programmable Relay
E
= Programmable Relay and Leaving Water
and Demand Limit Setpoint
F
= Percent Capacity
G
= Percent Capacity and Leaving Water and
Demand Limit Setpoint
H
= Percent Capacity and Programmable
Relay
Содержание Ascend ACR Series