Parameterization and Configuration
TR-Electronic GmbH 2018, All Rights Reserved
Printed in the Federal Republic of Germany
Page 134 of 167
TR - ELA - BA - DGB - 0027 - 03
11/12/2019
6.3.4.2.4 Supported errors (PNU 65001.03)
The parameter in Subindex 3 displays the errors supported by the measuring system.
Bits
Definition
= 0
=1
0
Position error
-
Supported
1-21
-
Not supported
-
22
Memory error
-
Supported
23-24
-
Not supported
-
25 - 31
reserved
6.3.4.2.5 Warnings (PNU 65001.04)
The parameter in Subindex 4 displays the current measuring system warnings.
Bits
Definition
= 0
=1
0-24
-
Always 0
-
25 - 31
reserved
6.3.4.2.6 Supported warnings (PNU 65001.05)
The parameter in Subindex 5 displays the warnings supported by the measuring system.
Bits
Definition
= 0
=1
0-24
-
Not supported
-
25 - 31
reserved
6.3.4.2.7 Encoder Profile Version (PNU 65001.06)
The parameter in Subindex 6 contains the profile version implemented in the measuring system.
Bits
Definition
0 - 7
0x02 (LSB)
Version no. 0x0402
8 - 15
0x04 (MSB)
16 - 31
reserved
6.3.4.2.8 Offset value 32-bit (PNU 65001.08)
The offset value in Subindex 8 is calculated internally during execution of the preset function and
offsets the position value by the calculated value. Each time the preset function is executed, the re-
calculated value is permanently stored and specified as a scaled value according to the set resolution.
Integer32, two's complement
Byte
X+0
X+1
X+2
X+3
Bit
31-24
23-16
15-8
7-0
Data
2
31
– 2
24
2
23
– 2
16
2
15
– 2
8
2
7
– 2
0