![TR-Electronic LMP-30 Скачать руководство пользователя страница 131](http://html1.mh-extra.com/html/tr-electronic/lmp-30/lmp-30_user-manual_1146711131.webp)
Printed in the Federal Republic of Germany
TR-Electronic GmbH 2018, All Rights Reserved
11/12/2019
TR - ELA - BA - DGB - 0027 - 03
Page 131 of 167
Example: Read back written preset value 1000 (decimal) via PNU 65000
Byte
Value
Meaning
0
0x02
Request reference
1
0x01
Request ID (read parameter)
2
0x00
Axis
3
0x01
Number of parameters
4
0x10
Attribute
5
0x00
Number of elements
6
0xFD
PNU (High Byte)
7
0xE8
PNU (Low Byte )
8
0x00
Subindex (High Byte)
9
0x00
Subindex (Low Byte)
Table 5: Record Data Request, read back preset value
Byte
Value
Meaning
0
0x02
Request reference, mirrored
1
0x01
Response ID (parameter read successfully)
2
0x00
Axis, mirrored
3
0x01
Number of parameters, mirrored
4
0x43
Format (Double Word)
5
0x01
Number of values
6
0x00
Value (MSB)
7
0x00
Value
8
0x03
Value
9
0xE8
Value (LSB)
Table 6: Record Data Response to read back preset value