![TQC AB3075 Скачать руководство пользователя страница 14](http://html1.mh-extra.com/html/tqc/ab3075/ab3075_user-manual_1146581014.webp)
14
7.2 Instrument Preparations
Position glass bed or vacuum bed between the designated red supporting studs at the 4 corners
on the unit. The heated vacuum bed model comes with a pre assembled vacuum bed. For the
other vacuum models follow the vacuum seal installation instructions in Annex A.
7.3 Glass Bed
This bed 470 x 300 x 12 mm can either be used directly as an application carrier or (for example)
smaller cards or foils.
Charts or foils are automatically clamped in a special device at the end of the unit as soon a test is
performed. For cleaning purposes the glass bed can be removed.
7.4 Perforated
Vacuum Bed
In order to create an adequate vacuum the instructions for setting up the vacuum seal O-rings
as in Annex A need to followed. The Perforated Vacuum Bed is automatically connected to the
vacuum pump as soon as placed between the red supporting studs on the O-rings.
The Perforated Vacuum Bed serves to hold thick foils, charts and other papers for coating.
The area size under vacuum depends on the selection made in the menu of the instrument
and on the model. (See 8.1 – RUN SETUP-LENGTH) See ANNEX E1 / E2 for more information on
Test Chart Placement.
7.5 Double Channel Vacuum Bed
In order to create an adequate vacuum the instructions for setting up the vacuum seal O-rings
as in Annex A need to be followed . Double Channel Vacuum Beds are used for testing on foils.
When otherwise the foil will not remain smooth on a normal vacuum bed. The Double Channel
Vacuum Bed only has vacuum in two concentrically rings on the outside of the bed. This requires
the foils to be about A3 size for the Double Channel Vacuum Bed to be able to hold them.
To prevent pollution of some holes outside the dimensions of charts we advise to cover the
surrounded area with paper or tape.
NOTE
For assembly please also watch included DVD
EN
Содержание AB3075
Страница 25: ...25 ANNEX C INSTALLATION OF THE LAMP Detail A scale 1 1 EN...
Страница 39: ...39 TQC GRINDOMETER TOOL FOR AFA AB3075 ANNEX F TQC GRINDOMETER TOOL FOR AFA EN...
Страница 41: ...41 ANNEX F GRINDOMETER TOOL FOR AFA Weight WWW TQC EU AB3075 WWW TQC EU AB3075 100 g 805 g 114 g EN...
Страница 42: ...42 ANNEX F GRINDOMETER TOOL FOR AFA Tool Operation 1 WWW TQC EU AB3075 WWW TQC EU AB3075 EN...
Страница 44: ...44 ANNEX F GRINDOMETER TOOL FOR AFA Height adjustment 3 WWW TQC EU A B 5 mm WWW TQC EU AB3075 EN...
Страница 46: ...46 ANNEX F GRINDOMETER TOOL FOR AFA After drawdown 5 WWW TQC EU AB3075 EN...
Страница 47: ...47 TQC HARDNESS PEN HOLDER TOOL FOR AFA AB3090 ANNEX G TQC HARDNESS PEN HOLDER FOR AFA EN...
Страница 48: ...48 ANNEX G TQC HARDNESS PEN HOLDER FOR AFA Dimensions 60 mm 140 mm 25 mm 52 mm 23 mm EN...
Страница 49: ...49 ANNEX G TQC HARDNESS PEN HOLDER FOR AFA Weight 500 g 2220 g EN...
Страница 50: ...50 EN ANNEX G TQC HARDNESS PEN HOLDER FOR AFA Tool Mounting...
Страница 52: ...52 EN ANNEX G TQC HARDNESS PEN HOLDER FOR AFA TEST PANEL PLACEMENT Vacuum models X Vacuum hole Mask Position...
Страница 54: ...54 EN...
Страница 55: ...55 EN...