Figure 13-8 Notification Config
The following entries are displayed on this screen:
¾
Create Notification
IP Address:
Enter the IP Address of the management Host.
UDP Port:
Enter the number of the UDP port used to send notifications.
The UDP port functions with the IP address for the
notification sending. The default is 162.
User:
Enter the User name of the management station.
Security Model:
Select the Security Model of the management station.
Security Level:
Select the Security Level for the SNMP v3 User.
z
noAuthNoPriv: No authentication and no privacy
security level is used.
z
authNoPriv: Only the authentication security level is
used.
z
authPriv: Both the authentication and the privacy
security levels are used.
Type:
Select the type for the notifications.
z
Trap: Indicates traps are sent.
z
Inform: Indicates informs are sent. The Inform type has
a higher security than the Trap type.
Retry:
Specify the amount of times the switch resends an inform
request. The switch will resend the inform request if it
doesn’t get the response from the management station
during the
Timeout
interval, and it will terminate resending
the inform request if the resending times reach the specified
Retry
times.
Timeout:
Specify the maximum time for the switch to wait for the
response from the management station before resending a
request.
189