Alarm Type:
Specify the type of the alarm.
•
Rising:
When the sampled value exceeds the Rising
Threshold, an alarm event is triggered.
•
Falling:
When the sampled value is under the Falling
Threshold, an alarm event is triggered.
•
All:
The alarm event will be triggered either the sampled
value exceeds the Rising Threshold or is under the Falling
Threshold.
Rising Event:
Select the index of the corresponding event which will be
triggered if the sampled value is larger than the rising
Threshold.
Rising Threshold:
Enter the rising counter value that triggers the rising threshold
alarm, ranging from 1 to 2147483647.
Falling Event:
Select the index of the corresponding event which will be
triggered if the sampled value is lower than the Falling
Threshold.
Falling Threshold:
Enter the falling counter value that triggers the falling
threshold alarm, ranging from 1 to 2147483647.
Interval:
Enter the alarm interval time in seconds, ranging from 10 to
3600.
Owner:
Enter the name of the device or user that defines the entry.
Operation:
Click “Edit” to edit the alarm group entry.
Note:
When alarm variables exceed the Threshold on the same direction continuously for several
times, an alarm event will only be generated on the first time, that is, the Rising Alarm and
Falling Alarm are triggered alternately for that the alarm following to Rising Alarm is certainly a
Falling Alarm and vice versa.
384