background image

The following symptoms are normal during operation of the heater.

White smoke or smell at initial use after
purchase.

Flames flashing for a few minutes after
ignition.

Occasionally makes “cracking” noise when
heater is ignited or extinguished.

Part of the heat chamber or the heat
exchanger is heated to a cherry red color.

Warm air will not blow as soon as ignited.

Audible chugging sound from fuel pump
when started first time or after running out
of fuel.

“Ticking” noise.

Machine oil or dust burns of the surfaces of
the burner or heat exchanger.

The burner is cold and igniter is kept running
for a while after ignition.

Expansion and shrinkage of metal parts when
they are heated or cooled.

To prevent uncomfortable cool air from
coming out at the beginning, circulation fan
start up is delayed.

Air is in the pump. However, noise should
stop within 1 minute.*

Noise of fuel pump in operation.
Normal.

Normal.

Occasional yellow flickering in blue flame.

Normal.

When heater is started

or extinguished.

When heater is

in operation.

CONDITION

REASON

SECTION G:
TROUBLESHOOTING

NOTE BEFORE REQUESTING FOR REPAIR AND SERVICES

AUTOMATIC CLEANING SYSTEM

Heater will automatically clean igniter for ten (10) minutes every day at 2:00 a.m. and display “CL:10” on 
Digital Indicator if heater is running at that time.

MANUAL CLEANING SYSTEM

Heater will clean igniter for ten (10) minutes manually.

1.     Press the “HOUR” button and “MINUTE” button at the same time for more than three (3) seconds when 

ON/OFF switch is “OFF”.

2.   Display will appear “CL:10” on Digital Indicator. Cleaning will begin and end without any additional 

input.

Note:   Cleaning igniter is important to prolong igniter life. It is recommended that the igniter be cleaned 

once a week.

*If sound from fuel pump does not decrease and heater shuts off, check:

1.

Push red reset button on fuel sump. DO NOT hold down.

2.

Insure that all valves are open and filter is clear.

3.

Insure external fuel tank has fuel and filters are clean.

14

  Laser 60AT (E)  11.3.3  0:59 PM  Page 14

Содержание Laser 60AT

Страница 1: ...Features SECTION B Safety Tips for Operation SECTION C Fuel Guide SECTION D Operating Controls and Part Names SECTION E Operation Before Ignition Operation Turning Heater Off SECTION F Routine Mainten...

Страница 2: ...l Oil or ASTM D975 Ultra Low Sulfur Diesel ULSD 30 24 19 76 0 60 8 48 3 cm 77 lbs 35 kg Empty 2 3 4 3 diameter 7 0 7 5 cm 10 ft 3 m 3 bends or less 120 Volts AC 60 Hz Preheat 280W Burning 60W 1250 squ...

Страница 3: ...prevent fire Power Failure Recovery System If power fails during heater operation heater will turn off When power resumes heater will automatically reignite to maintain the selected room temperature...

Страница 4: ...Ultra Low Sulfur Diesel ULSD NEVER USE GASOLINE Use of gasoline can lead to uncontrollable flames resulting in destructive fire 1 Due to high surface temperatures keep heater away from children furnit...

Страница 5: ...cause Use of a highly volatile flammable fuel such as gasoline can produce uncontrollable flames creating a severe fire hazard Note The fluidity of Ultra Low Sulfur Diesel becomes worse at temperature...

Страница 6: ...K SET CLOCK TEMP START SET BACK 50 10 70 21 90 F 32 C END SET BACK SET BACK NORMAL AUTO AM PM HOUR AUTO 8 ON OFF lamp 10 Normal temper ature lamp 1 ON OFF switch 5 Timer selector 3 Temperature selecto...

Страница 7: ...heating room up quickly and low or medi umcapacity warm air flow during low or medium combustion for maintaining comfortable room temperature Constantly senses room temperature and supplies informatio...

Страница 8: ...20479956 20474050 20476482 20479958 20474051 20476452 20475554 20476454 20474053 20474055 20474057 20450120 20475874 20474272 20479957 20479885 20479996 20479998 Front panel Plumb bob Adjustable leg...

Страница 9: ...t output will however be automatically adjusted in accordance with the room temperature registered by the temperature sensor Operation of Laser Heater can be controlled manually by the user MANUAL ope...

Страница 10: ...e selector to set the room temperature desired The temperature control should be set at the position you find most comfortable Note Desired temperature setting will be displayed on the digital indicat...

Страница 11: ...selector and SET BACK temperature selector at the position you desire Ex NORMAL 75 F SET BACK 60 F Note The temperature setting currently being used is displayed on the digital indicator To view and...

Страница 12: ...isconnected during electrical storms Note Heater may also be shut down by lowering the setting on the temp selec tor thermostat s because heater goes into OFF cycle SECTION F ROUTINE MAINTENANCE Impor...

Страница 13: ...ainer and wash with kerosene e Return the strainer to its original position Replace strainer cover and screw to secure f Wipe away any spilled fuel g Open the valve s of separate fuel tank Check for f...

Страница 14: ...Normal Occasional yellow flickering in blue flame Normal When heater is started or extinguished When heater is in operation CONDITION REASON SECTION G TROUBLESHOOTING NOTE BEFORE REQUESTING FOR REPAI...

Страница 15: ...our dealer Consult your dealer EE10 DOES NOT EXTINGUISH Possibly excess fuel in burner Flame sensor malfunction Consult your dealer Consult your dealer ODOR Leaking flue pipe Fuel leakage Faulty packi...

Страница 16: ...ur heater needs any service or repair now is the time to call your dealer and get it done before storage That way your heater will be ready for immediate use when the next heating season begins 3 If y...

Страница 17: ...installation parts are enclosed with heater For alternate installation methods you may need to purchase additional accessories which are available from your TOYOSTOVE dealer See Accessory Parts page...

Страница 18: ...ap 1 PART 20474949 Screw 4G 3 PART 20474985 Oil Catch 1 PART 20474925 Inlet Hose 1 PART 20474951 Spacer 1 PART 20478967 Screw M 3 PART 20474272 Bent Joint 1 PART 20474984 L Shaped Hose 2 PART 20474975...

Страница 19: ...er and flue pipe locations and fueling system consult your TOYOSTOVE dealer to purchase the necessary accessory parts Important Use only genuine TOYOSTOVE parts for your heater Use of unauthorized gen...

Страница 20: ...r Pipe Support Hardware L Shaped Exhaust Joint 1 1 1 2 2 3 sets 1 NOTE Use L shaped Exhaust Joint if necessary INSTALLATION WITH EXTENSION PIPE KIT L Adjustable Exhaust Pipe Insulation cloth cover Exh...

Страница 21: ...it S PART 20479896 No Name of Part Q ty 1 2 3 4 5 6 Adjustable Exhaust Pipe Max 19 11 16 Min 12 5 8 Intake Pipe 20 inch Insulating cloth cover 40 inch Pipe Holder Pipe Support Hardware L Shaped Exhaus...

Страница 22: ...in your wall for the flue pipe make sure the area is free of electrical wires gas pipes and other obstacles 4 Do not install flue pipe where it will be exposed to heavy snow collected leaves or strong...

Страница 23: ...e Fig 2 3 CAUTION The standard flue pipe installation as shown in Fig 2 is for wall thickness from 4 in to 9 in ONLY Note For wall thickness more than 9 in refer to page 18 for available flue pipe ext...

Страница 24: ...the heat exchanger c Gently insert the ceramic logs into three 3 brackets inside of burner properly After inserting the ceramic logs install log supporter on the upper holes of the ceramic logs Adjus...

Страница 25: ...inside the room Use a 2 3 4 to 3 diameter hole saw attached to an electric drill See Fig 5 The opening on the inside wall should be slightly higher than the outside opening approximately 1 4 so that...

Страница 26: ...ugh the hole Secure the outer flue pipe to the wall by turning it clockwise This locks the two halves together See fig 9 IMPORTANT Make sure the arrow on the outer flue pipe flange is pointing up Make...

Страница 27: ...ater Make sure the caps fit tightly onto the opening See Fig 10 NOTE If the inlet hose is not smoothly inserted into the L shaped hose apply water or soap suds to the inlet hose 8 Move the heater into...

Страница 28: ...exhaust outlet opening by sliding the pipe stopper in the exhaust opening bracket See Fig 12 10 Make sure the position of the heater is level by using the plumb bob located at the right side of the he...

Страница 29: ...heater a Self Adhesive Tape Peel off the protective tape on the back of the sensor and expose the adhesives Place the sensor on the desired location on the wall and press down b Wood Screw Screw down...

Страница 30: ...ine and connected the tank as illustrated on page 30 NOTE An additional shut off valve installed next to the exterior wall will minimize fuel to be drained should heater have to be disconnected If the...

Страница 31: ...er 60AT Fuel filter 8 1 2 ft maximum 16 in minimum Tank Vent Outdoor Fuel Tank Shut off Valve Loop 3 8 in OD Copper Tubing Shut off Valve Fusible link valve inside 31 Laser 60AT E 11 3 3 0 59 PM Page...

Страница 32: ...bill of sale or credit card charge receipt or other documents evidencing the date of the Product s delivery if service is not available locally please contact our CUSTOMER RELATIONS DEPARTMENT at TOYO...