PROBLEM
DISPLAY/LAMP
CAUSE
SOLUTION
POWER LAMP
FAILS TO TURN ON
Disconnected power plug
Circuit board malfunction
Plug into 120V AC outlet.
Consult your dealer.
EE2
EE2
EE2
EE2
EE2
EE2
EE8
NO IGNITION*
Out of fuel
Fuel tank valve closed
Air pocket in fuel line
Clogged flue pipe
Clogged fuel strainer
Igniter, circuit board, flame
sensor or fuel pump malfunction
Blower motor malfunction
Check fuel gauge on fuel tank; refuel.
Open valve by turning counterclockwise.
Push reset button on the fuel sump,
located right inside, once.
Clean flue pipe.
Clean fuel strainer (See page 13).
Consult your dealer.
Consult your dealer.
EE6
EE6
EE6
EE6
EE6
EE6
EE6
EE8
EXTINGUISHED
AFTER IGNITION
Air pocket in fuel line
Out of fuel
High limit switch activated
Fuel flow obstruction
Tank too high
Fuel sump valve malfunction
Flame sensor malfunction
Blower motor malfunction
Push reset button on the fuel sump,
located right inside, once.
Check fuel gauge on fuel tank; refuel.
Clean circulation fan cover, remove any
obstructions.
Consult your dealer.
Re-locate fuel tank.
Consult your dealer.
Consult your dealer
Consult your dealer.
POOR COMBUSTION/
NOISY COMBUSTION
Soot buildup in flue pipe
Burner ring not properly seated
Altitude too high (See page 23.)
Clean out any soot.
Consult your dealer.
Consult your dealer.
EE10
DOES NOT
EXTINGUISH
Possibly excess fuel in burner
Flame sensor malfunction
Consult your dealer.
Consult your dealer.
ODOR
Leaking flue pipe
Fuel leakage
Faulty packing or gasket in
combustion area
Tighten all flue pipe connections.
Tighten all fuel line joints. Wipe away any
fuel drippage.
Consult your dealer.
Hi
Room temp is over 95˚F.
Incorrect location of room temp
sensor
Correct the location of the room temp
sensor.
Lo
Room temp is lower than 14˚F.
Room temp sensor malfunction or
disconnected
Check room temp sensor.
Low/Med/
High lamps
flashing at
the same
time
DOES NOT
EXTINGUISH
Possibly excess fuel in the burner or
flame sensor
malfunction (miss detection)
Consult your dealer.
Should problems arise during operation or ignition, use this chart to determine the cause and the proper
steps to take. Be sure to unplug heater and allow to cool completely before taking corrective measures.
In the event that heater should extinguish itself, without any action or your part, you should look to the
digital indicator for any of the following error codes.
WARNING:
Do not re-use the unit until the cause of the “EE10” code has been determined.
If the corrective measures outlined above do not solve the problem, please consult your TOYOSTOVE dealer.
*Note: If the unit fails 3 times after checking all causes listed, DO NOT CONTINUE turning the power switch
on and off. (Consult your dealer.)
15
Laser 60AT (E) 11.3.3 0:59 PM Page 15