FOR OPTIMUM HEATER PERFORMANCE, THE PARTS SHOWN BELOW SHOULD BE CLEANED REGULARLY:
CAUTION
:
Be sure to unplug heater before performing any checks or cleaning.
CAUTION
:
Allow heater to cool completely before cleaning or maintenance.
TURNING HEATER OFF
MANUAL COMBUSTION
Press ON/OFF switch to “OFF” position. (AUTO lamp and temperature lamp will
go out. Burning mode lamp will flash until flame disappears.) Circulation fan and
blower motors continue to run for approx. three (3) minutes to cool down the
heater. Make sure ON/OFF lamp goes out when the fan stops.
Note: If ON/OFF switch is pressed to “ON” position during the cool down peri-
od, the heater will automatically re-start at the end of cool down period.
Note: Disconnect the heater plug from the electrical outlet after the power lamp
has turned off if the heater will go unused for a prolonged period. The
plug should also be disconnected during electrical storms.
Note:
Heater may also be shut down by lowering the setting on the temp. selec-
tor thermostat(s) because heater goes into “OFF” cycle.
SECTION F:
ROUTINE MAINTENANCE
Important:
This feature is for testing purpose only!
This heater also can be kept burning at desired combustion mode (High, Medium or Low) manually, regardless of room
temperature.
1.
Press the “HOUR“ button and “MINUTE“ button at the same time for more than three (3) seconds when
ON/OFF switch is “ON“.
2.
P1, P2 or P3 will be displayed on the Digital Indicator;
P1 = Low mode
P2 = Medium mode
P3 = High mode
Then select desired combustion mode by pressing “MINUTE“ or “HOUR“ button. “MINUTE“ button changes com-
bustion mode to higher, “HOUR“ button changes combustion mode to lower.
3.
To clear, press the “HOUR“ button and “MINUTE“ button at the same time for more than three (3) seconds until
normal temperature display returns.
BURNER
(NORMAL POSITION)
CLOCK SET
CLOCK / TEMP
START
SET-BACK
50
10
70
21
90 F
32ºC
END SET-BACK
AUTO
Circulation
air filter
Furl strainer
(inside)