66
Maximum length of refrigerant pipe
Maximum Length of Refrigerant Pipe
Outer diameter of pipe
:
mm Length of Connecting pipe (L)
:
m
Model
Maximum length of
refrigerant pipe (A)
:
m
Gas Liquid Indoor
unit
Outdoor
Unit
9000 BTU
10
9.52
12000 BTU
18000 BTU
15 12.7
6.35 0.43 0
Maximum height difference
※
Maximum height
difference: 5m
Maximum length of refrigerant pipe (A)
※
It does not matter if the outdoor unit is in higher position.
Replenishment amount of refrigerant
(
(
(
(
R-22
:
:
:
:
g
)
)
)
)
Length of refrigerant pipe
(
one way
)
Model
Profiled refrigerant for outdoor unit
(
Max. 7m
)
7m 10m 15m
9000 btu cooling only
900
12000 btu cooling only
800
18000 btu cooling only
1650
0
45
120
9000 btu cooling only
850
12000 btu cooling only
1150
18000 btu cooling only
1800
0
150
400
Computation
:
:
:
:
Replenishment amount=15/L×(A-7)
Indoor