13
6. Swing louver action in Cooling Mode:
6.1 Natural flow
Swing louver direction is as following chart:
swing two girths
——
stop for 1 minute
——
swing two girths
——
stop for 1 minute
120
0
0
0
42
0
52
0
off place
65
0
62
0
60
0
6.2 Swing
If swing louver swings up and down, swing range is about 55
0
.
120
0
0
0
5
0
off place
60
0
6.3 When swing louver is under swing mode, press “AIR FLOW” button by the remote controller and the swing
louver will stop in the direction where it is.
6.4 When the unit is in cooling mode, the swing louver’s working is independent with compressor’s working.
7. Preventing Indoor coil frost in cooling mode:
1) Indoor coil temperature is
≤
1
℃
,
and the compressor has been in working for 6 minutes already, turn off
compressor, and indoor fan motor changes into low flow mode.
2) Indoor coil temperature is
≥
8
℃
,
and the compressor has already been off more than 3 minutes, restart the
compressor, indoor fan motor works as it is set.
8. Compressor and outdoor fan control (Ta = room temp. Ts = set temp.)
When Ta - Ts is equal or higher than 1
℃
and the compressor is fulfilled the condition of 3 minutes delay, outdoor fan
motor starts first for 5 minutes, and then compressor starts; when Ts – Ta is equal or higher than 1
℃
, the compressor
stops, outdoor fan motor will stop after working for 20 seconds, and can be restarted after 3 minutes.