. Indoor unit control
1. Auto mode
1) When Ta
≥
25
℃
: choose cooling mode automatically, set temperature is 24
℃
;
2) 21
℃≤
Ta
<
25
℃
: choose dehumidifying automatically, set temperature is 22
℃
;
3) Ta
<
21
℃
: choose heat automatically, set temperature is 23
℃
.
Note: in auto mode, there is nothing shown on the panel.
2. Cooling mode
2.1 Temperature control: 18
℃
~29
℃
;
2.2 Compressor control:
2.2.1 3 minutes protection
1) 3 minutes delay function of first usage of the compressor.
2) 3 minutes interval when restarting the compressor.
2.2.2 When Ta is higher than Ts, the compressor runs, if Ta is equal or lower than Ts, the compressor stops.
2.2.3 When in inspection function, the compressor stops.
2.2.4 Anti indoor evaporate frosting function:
1) when the compressor continue working for 16 minutes, if the indoor coil thermistor is lower than 1
℃
the
compressor will stop.
Содержание TA-05CW