51
ON/OFF button can be used to control the power.
MODE SELECT control as below:
COOL DRY HEAT(FAN)
FAN SWEED control as below:
HIGH
(
MED
)
LOW
Three fan speed to choose: High
、
Middle
、
Low. When in middle air speed, the high speed and low speed
indicator light on the same time.
TIMER MODE control as below:
TIMER OFF TIMER ON CANCEL TIMER
Set time from 1
~
12 hours, every interval is 1 hour, and the light go off one by one every hour.
TIMER/TEMP control as below:
TIMER TEMP
Press TIMER/TEMP button, can switch the mode between Timer and Temp, set temperature is from 18
~
29
℃
,
interval is 1
℃。
UP and DOWN button can be used to change the temperature or hour.
3. Heat mode
1) If Ta is lower than Ts, first start-up or 3 minutes delay later, the compressor runs, if Ta is higher than Ts + 3
℃
the
compressor will stop, and begin 3 minutes delay function.
Compressor stop
Compressor stop
Ts + 3
℃
Ts
Heat
Heat
Anti cold wind function:
Set fan speed
Set fan speed
36
℃
31
℃
Low
30
℃
Low flow
Stop air
25
℃
Stop sending air when compressor stop
a When the compressor stops, indoor fan runs as above chart
b When the compressor runs, indoor fan never stops.
c When indoor coil temperature is lower than 31
℃
indoor fan works in low air flow mode.
2) Electricity heat control
Do
w
n
Up
Содержание TA-05CW