Configuring the EPW 400
OM 100.EPW 400.202002.en
95
Close the 'Job counter' window by tapping on the 'Accept' button. The
displayed values will be adopted.
6.4.2
Shift counter
To open this menu, tap on the 'Shift counter' button:
In the text fields of the first two lines of this menu all OK parts as well as the total
number of parts produced in a shift are displayed. Both counter readings are set to
zero by pressing the 'Reset' button.
If in text field 'Message at' a certain quantity of the counter is entered with the numer-
ical keypad, a message with a yellow background will be displayed as soon as this
reading is reached. The work cycle is not stopped with this function.
If a certain quantity is entered in text field 'Switch off at' using the numerical keypad,
the work cycle will be stopped when this reading is reached. A counter value message
(with a red background) is issued. A continuation of the process is only possible after
the acknowledgement of the error. The counter reading must first be reset, as other-
wise the counter will once more be exceeded and the machine will stop again at the
next process.
The value '0' of the text fields 'Message at' and 'Switch off at' deselects the corre-
sponding option (no message or no switching-off of the machine).
If the tick is set in 'Main menu', the value will be displayed in the second line of the
main menu. Only one counter can be displayed in the main menu.
Close the 'Shift counter' window by tapping on the 'Accept' button. The
displayed values will be adopted.