Configuring the EPW 400
OM 100.EPW 400.202002.en
107
6.6.10 Read inputs to Anybus-S module
Activation of the device via field bus
Activation of the device via digital inputs/outputs.
For changeover, tap on the input field next to 'read inputs from anybus module'.
6.6.11 Log final values on field bus
The final values will be output to the field bus interface
For changeover, tap on the input field before 'read final values on anybus module'.
6.6.12 Write actual values
When this checkbox is activated, the measured values of force and distance are con-
tinuously output on the field bus.
6.6.13 Read DMC code
This field can be used to specify that the data matrix code is to be read via field bus.
The data matrix
code is a piece part designation with a max. of 56 characters.
The character 0 (0x00) applies as the end of the string for less than 56 char-
acters.
There are options that the string is read with the start of measurement, here it
must be applied to the bus before the start of measurement, or at the end of
measurement, here it must be applied before the end of measurement.
6.6.14 Number of IO bytes
With this field the number of I/O bytes configured on the bus are specified. A maximum
of 64 bytes for inputs and outputs is possible.
The value refers each to the inputs and outputs, while the number of inputs and out-
puts is always equal. The value 16 would therefore activate 16 input bytes and 16
output bytes on the bus. The functions on input and output bytes 17 - 63 could there-
fore not be reached.
Close this window by tapping on the 'Accept' button. The displayed pa-
rameters will be adopted.