Technical data
42
OM 100.EPW400.202002.en
3.4.2
Fieldbus interface
Data length: Byte 0-2
Inputs I0-I15
Designation
Field bus byte
Field bus bit
I 0
Program bit 0
0
0
I 1
Program bit 1
0
1
I 2
Program bit 2
0
2
I 3
Program bit 3
0
3
I 4
Program bit 4
0
4
I 5
Program bit 5
0
5
I 6
Program strobe
0
6
I 7
Offset external
0
7
I 8
Start measurement
1
0
I 9
Reserve
1
1
I 10
Control panel inter-
lock
1
2
I 11
Error reserve
1
3
I 12
Reserve
1
4
I 13
Configurable input
1
5
I 14
Access level bit 1
1
6
I 15
Reserve
1
7
Outputs Q0-Q7
Designation
Field bus byte
Field bus bit
Q 0
OK
0
0
Q 1
NOK
0
1
Q 2
NOK alarm
0
2
Q 3
Switching point S1
0
3
Q 4
Switching point S2
5
0
4
Q 5
Ready for measure-
ment
0
5
Q 6
Program ACK
0
6
Q 7
Switching point S3
5
0
7
5
Output function options:
Switching point S1 / Enable
Switching point S2 / Buzzer
Switching point S3 / Warning piece counter