Configuring the EPW 400
92
OM 100.EPW400.202002.en
W1 D_in
Distance entry in window 1
W1 F_out
Force exit in window 1
W1 D_out Distance exit in window 1
W1 F_mid Force average in window 1
You can scroll upwards, downwards, right and left using the arrow keys
,
,
and
.
Close the 'Curve data' menu by tapping on 'Exit'.
Delete the final values by tapping the 'Dustbin' button.
Additional display of sampling rate and valuation time in ms (authoriza-
tion level 3 only).
This button saves the recorded curves to a connected USB stick as a
CSV file. The last 1000 end value data sets will be saved and then cop-
ied to the USB stick. The name of the EPW 400 device as well as date
and time will be used as name of the data file. The data can be found
on the USB stick in the "Tox\Archive" folder.
6.3.3
Settings
Here you can choose whether to receive a message after a measurement or whether
the final values will be stored.
If the control box is activated, the operator must confirm after each measurement
whether the measurement shall be saved with the final values or not.
If the control box is not activated, each measurement will be automatically added to
the end values.