Technical data
OM 100.EPW 400.202002.en
43
Format of final values via fild bus (bytes 3 – 63):
The end values are written on bytes 3 to 55 on the field bus (if this function is acti-
vated).
•
Byte X (structure):
7
6
5
4
3
2
1
0
Byte X
Byte 3:
Status (Status 2 = OK / Status 3 = NOK)
Byte 4, 5, 6, 7:
Running number
Byte 8:
Program
Byte 9:
Reserve
Byte 10, 11:
Max. force [kN] * 100
Byte 12, 13:
Max. distance [mm] * 100
Byte 14:
Second
Byte 15:
Minute
Byte 16:
Hour
Byte 17:
Day
Byte 18:
Month
Byte 19:
Year
Byte 20, 21:
Window 1, actual force [kN] * 100 (for actual distance [mm])
Byte 22, 23:
Window 1, force upper limit [kN] * 100
Byte 24, 25:
Window 1, force lower limit [kN] * 100
Byte 26, 27:
Window 1, actual distance [mm] * 100
Byte 28, 29:
Window 1, distance upper limit [mm] * 100
Byte 30, 31:
Window 1, distance lower limit [mm] * 100
Byte 32, 33:
Window 2, actual force [kN] * 100 (for actual distance [mm])
Byte 35, 35:
Window 2, force upper limit [kN] * 100
Byte 36, 37:
Window 2, force lower limit [kN] * 100
Byte 38, 39:
Window 2, actual distance [mm] * 100
Byte 40, 41:
Window 2, distance upper limit [mm] * 100
Byte 42, 43:
Window 2, distance lower limit [mm] * 100
Byte 44, 45:
Window 3, actual force [kN] * 100 (for actual distance [mm])
Byte 46, 47:
Window 3, force upper limit [kN] * 100
Byte 48, 49:
Window 3, force lower limit [kN] * 100
Byte 50, 51:
Window 3, actual distance [mm] * 100
Byte 52, 53:
Window 3, distance upper limit [mm] * 100
Byte 54, 55:
Window 3, distance lower limit [mm] * 100
Byte 56, 57:
Actual value force [kN] * 100
Byte 58, 59:
Actual value distance [mm] * 100
Byte 60 - 63:
Reserve