Pneumatic press PFHL
/
PFHW
28
OM 45.PFHL-PFHW.201803.en
9 Failures: Causes and their elimination
Safety regulations
When working on the machine, always observe the applicable
safety regulations and the legal conditions.
Observe the instructions in chapter 3 'Safety' of these Operating
Instructions.
TOX
®
-Pneumatic presses with manual approach type PFHL / PFHW
Failure
Cause
Elimination
Safety
Impossible to move
the ram
– Mechanic defect
of guide
Have it repaired
(specialists)
Protect the toggle press
Power stroke is not
initiated
– Insufficient air pressure
– Pneumatic supply at
cylinder is defective
– Mechanic defect of
pneumatic cylinder
– Control system defec-
tive
– Damaged seals
Check air pressure for
this working process and
increase it, if necessary
Have it repaired
(specialists)
Have it repaired
(specialists)
Have it repaired
(specialists)
Have it repaired
(specialists)
Observe maximum value
of air pressure
Depressurize machine
and protect it against
reclosing
Depressurize machine
and protect it against
reclosing
( Depressurize machine
and protect it against
reclosing
Depressurize machine
and protect it against
reclosing
Press force not
reached
– All causes described in
'Power stroke is not initi-
ated'
are possible here
– Press head not suffi-
ciently fastened
see "Ram can not be
moved"
Tighten fastening screws
uniformly (torque depends
on screw quality)
ð see "Ram can not be
moved"
Depressurize machine
and protect it against
reclosing
Information on failure elimination of other components can be found in the corresponding manuals of
the documentation.
The problem could not be fixed?
Please contact our distribution partner or our company directly:
TOX
®
PRESSOTECHNIK GmbH & Co. KG
Riedstraße 4
D-88250 Weingarten
Tel.
+49 (0) 751/5007-0
Fax +49 (0) 751/52391
E-Mail [email protected]