Disassembly of Strainer Assembly
1) Using a hex or socket wrench, remove the four screws and washers from the cover plate.
2) Remove the cover plate and o-ring from the housing.
3) Remove the strainer screen.
4) Check inside housing for any debris and remove using a clean cloth.
5) Clean strainer screen by rinsing with a liquid cleaning agent compatible to your product application. A brush
may be used to remove imbedded particles. If screen is too dirty to clean, then replace the screen.
6) Wipe clean the face of the cover plate and seal ring. Check o-rings for damage and replace as needed.
Reassembly of 720 Strainer Assembly
1) Replace the strainer screen into the housing.
2) Place the end cover o-ring in the groove of the end cover.
3) Put the end cover with o-ring installed on the strainer housing. Replace and fasten end cover with the 4 screws
and washers. Tighten the screws according to the torque chart.
WARNING
All internal pressure must be relieved to ZERO (0) pressure before beginning disassembly
of meter or components
Содержание 700-LP Series
Страница 10: ...Page 10 Meter Dimensions in Inches Millimeters...
Страница 14: ...Page 14 700 20 LP Meter Assembly...
Страница 16: ...Page 16 730 20 LP Vapor Eliminator Assembly...
Страница 18: ...Page 18 720 20 LP Strainer Assembly...
Страница 20: ...Page 20 757 20 LP Differential Valve Assembly...
Страница 22: ...Page 22 782 20 LP In Line Check Assembly...
Страница 45: ...Page 45 Page 45 NOTES...
Страница 46: ...Page 46 Page 46 NOTES...