Reassembly of Meter
Reinstalling Rotors
1)
Install rear bearing plate on meter.
2) Insert threaded end of blocking rotor and the right displacement rotor into front gear plate (reinsert rotor keys if
necessary).
3) Align the two rotors (see picture 3) before applying gears.
Rotor Gear Timing
1) Slide on blocking rotor gear and position the ‗arrow‘ that it is pointing toward the right displacement gear.
2) Align ‗arrow‘ on displacement gear with the ‗arrow‘ on the blocking gear and slide on right displacement
gear.
3) Rotate the blocking rotor gear toward the left displacement gear and again align ‗arrows‘ and slide on left
displacement gear.
4) Gears and rotors should rotate freely if gears have been installed properly. If so, proceed with starting on the
lock nuts until finger tight.